Get complete information related to latest Odour Control System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Odour Control System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Odour Control System Tenders.
Tender For quotation for different items for preparation of estimate-hopper tipper use for garbage,tractor trolly,jetting machine for cleaning / washing purpose
Tender For corrigendum : the items mainly included in the estimate are rust proofing processes chipping of unsound concrete cleaning of reinforcement applying bonding coat, applying sbr polymer for the rcc water tank 9 mm plastering of top slab of rcc water etc
Tender For repair / maint including cleaning of soak wells, septic tanks, filter beds and other connected sewerage items in the aor of age b/r-iii under ge (awc) mhow
Tender For repair/replacement of external water supply pipe lines, valves and chambers, pump set, cleaning of external water supply tanks and other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For supply of set of esd safe cleaning brushes, one set consist of 03 items: (1) esd cleaning soft bristle brush, qty. 01 no./set. (2) esd safe cleaning brush vertical type wide soft bristles, qty. 01 no./set. (3) esd safe cleaning brush vertical type with long soft bristles, qty. 01 no./set. set details as per annexure-i attached. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]