Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For bid to ras corrigendum : supply of cnc vertical machining center vmc with continous 4th axis , rotary table with tailstock , atc , panel cooler ac , coolant system , hydraulic system , pre- dispatch inspection -pdi , installation and commissioning , stabilizer , standard tools and toolbox , hand held gun , hand coolant gun , set of spares for machine maintatinence , oil skimmer , first fill of lubricating oils,coolant. , document and manuals , packaging and forwarding
Tender For supply of angular carved teak wood 8 seater restaurant table including fitment at rly. inspection car/ coach. [ warranty period: 30 months after the date of delivery ]
Tender For supply and installation inspection table (kitply or centurion or guaranteed plywood) laminated top and 4 support legs + centre support (teak wood legs) size 10 feet x 1.25 feet x 19 mm thick for oms coach no. lwsczac 081513. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : design, engineering, submission of drawings for approval, manufacture, testing, inspection by mecon/dsp/cet, packing, loading, delivery at plant site/ storage area, supervision of erection, supervision of testing & supervision of commissioning of electrical equipment as mentioned under bill of quantities (table-3) and design, engineering, submission of drawings for approval, manufacture, testing, inspection by mecon/dsp/cet, packing, loading, delivery at plant site, storage, watch & ward, loading for transportation to erection site, unloading at erection site, dismantling, erection, testing & commissioning of retrofitting & extension works as mentioned under bill of quantities (table-1 & 2) , required for upgradation of blast furnace no. 3 at sail, durgapur steel plant.
Tender For providing, supplying and fixing cabin, table etc. for inspection 1 and 2, finance and budget dept. for hon. hight court on 2nd floor, mtnl fountain building no.1, at fort, mumbai.