Get complete information related to latest Oil Gland Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oil Gland Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oil Gland Tenders.
Tender For annual maintenance work of fire fighting system and refilling of existing fire extinguishers, supplying of neccessary fire fighting materials and other allied works in lok bhavan premises, bengaluru (from 01-08-2026 to 31-07-2027)- item description: engaging of mechanic-i. the work is to be carries out as per the directions of the engineer -in-charge of the work -notification no. kae 83 lmw 2022 dated 13-01-2023 , item description: providing oiling, gland packing, greasing, replacing damaged rubber gaskets using cotton waste clothes to maintain pumps, motors and fire equipments complete, including cost of all materials, labour charges, with all lead and lift, loading and unloading, transportation, machineries and all other incidental charges for successful completion of the work as per directions of the engineer-in-charge of the work. (se office letter 2184, dated 20.02.2025, sl.no 4) , item description: refilling of existing fire extinguisher for abc powder based map50, 4kg. there filling rate shall include costo fall lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete asper specification and directions of the engineer in charge of the work.. (sr 23-24, sl no 15.166, pg no 100,vol -6) , item description: refilling of existing fire extinguisher for abc powder based map50, 2kg. there filling rate shall include costo fall lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete asper specification and directions of the engineer in charge of the work. (sr 23-24, sl no 15.165, pg no 100,vol -6) , item description: refilling of existing c02 wheel type fire extinguisher 4.5kg. the refilling rate shall include cost of all lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.. (sr 23-24, sl no 15.192, pg no 103,vol -6) , item description: refilling of existing c02 squeeze grip fire extinguisher 2kg. the refilling rate shall include cost of all lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.. (sr 23-24, sl no 15.191, pg no 103,vol -6) , item description: refilling of existing c02 wheel type fire extinguisher 22.5kg.there filling rate shall include cost of all lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.. (sr 23-24, sl no 15.195, pg no 103,vol -6) , item description: refilling of existing fire extinguisher for abc powder based map90, 25kg.the refilling rate shall include cost of all lead and lifts, transportation, loading, unloading,fixing and all other incidental charges etc.complete as per specification and directions of the engineer in charge of the work.(sr 23-24, sl no 15.195, pg no 103,vol -6) , item description: supplying of hand gloves. complete. (15.113, vide (2023-24) sr, vol-6 , item description: supplying of first aid box. complete (pwd sr 2023-24, i.no. 15.114, vol-6) , item description: supplying of safety mask. complete (pwd sr 2023-24, i.no. 15.115, vol-6) , item description: providing brass polish for hydrant valves including cleaning, and two coats using upto 50ml polishing liquid to the valves, complete, including cost of all materials, labour charges, with unloading, transportation, machineries all lead and lift, loading and and all other incidental charges for successful completion of the work as per specification and directions of the engineer in charge of the work.(se office letter 2184, dated 20.02.2025,,sl.no 9) , item description: scrubbing, removing and applying of one coat of red oxide primer and final two coats of signal red paint on existing gi pipes 100mm nominal bore etc.,complete with all leads and lifts as per spe
Tender For corrigendum : supply of spare for co2 compressor - nfl material code:-mu10ccgb1010000640 front steam gland assembly for ugb-101 drive turbine, turbine model no.: ek 800-2; turbine sr.no.: t-0118. make: m/s srirama industries hyderabad and bhel are acceptable only., nfl material code:-mu10ccgb1010000641 balance piston gland assembly for ugb-101 drive turbine, turbine model no.: ek 800-2; turbine sr.no.: t-0118. make: m/s srirama industries hyderabad and bhel are acceptable only., nfl material code:-mu10ccgb1010000642 intermediate steam gland assembly for ugb-101 drive turbine, turbine model no.: ek 800-2; turbine sr.no.: t-0118. make: m/s srirama industries hyderabad and bhel are acceptable only., nfl material code:-mu10ccgb1010000643 rear steam gland assembly for ugb-101 drive turbine, turbine model no.: ek 800-2; turbine sr.no.: t-0118. make: m/s srirama industries hyderabad and bhel are acceptable only., nfl material code:-mu10ccgb1010000644 oilgland front/rear assembly for ugb-101 drive turbine, turbine model no.: ek 800-2; turbine sr.no.: t-0118. make: m/s srirama industries hyderabad and bhel are acceptable only.
Tender For bid to ras tender for supply of disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed