Get complete information related to latest Oil Analysis Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oil Analysis Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oil Analysis Tenders.
Tender For tender for supply of facility management contract of e and m installations of salem airport d d -monitoring and maintenance of utility services/internal and external electrical services at salem airport comprising of lt panels , dg sets , ccr panels , runway lighting , high masts , perimeter lighting , indoor and outdoor light fittings , power points , circuit/submain wiring , dbs , aviation obstruction lights , lightning arrestors , street light poles/external lights , signages etc. , (as per annexure-3 to 5 - list of inventories ) on duty basis by deputing sufficient number of manpower as per annexure-1 (8 hours of duty of time as decided by engineer-in-charge) , monitoring , control and general maintenance for 100% serviceability and i/c providing consumable material like cotton waste , oil , grease & other sundry material required for cleaning etc. , attending minor faults of equipments/ repairs/ replacement of defective components with aai supplied new components , ensuring 100% serviceability/ satisfactory working condition of the systems , routine and general preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/ yearly basis as per standard manufacturers practices and as per techno commercial specifications (tcs) , maintenance of records and log books (as per annexure-6 to 20) and reporting as and when required , complete upkeeping of the installations etc. , on all days as specified and as directed by engineer-in-charge as required. , maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming , repairs and maintenance , attending faults of systems , replacement of defective components with aai supplied new components , ensuring 100% serviceability/satisfactory working condition of fas , routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices , break-down maintenance , maintenance of records/service reports and reporting as and when required , complete up-keeping of the installations (fas) , as specified and as directed by engineer-in-charge as required. for first year (terminal building & technical block (make- edwards , model-io-1000)) , maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming , repairs and maintenance , attending faults of systems , replacement of defective components with aai supplied new components , ensuring 100% serviceability/satisfactory working condition of fas , routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices , break-down maintenance , maintenance of records/service reports and reporting as and when required , complete up-keeping of the installations (fas) , as specified and as directed by engineer-in-charge as required. for first year (ndb room (make- edwards , model-io-64)) , maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming , repairs and maintenance , attending faults of systems , replacement of defective components with aai supplied new components , ensuring 100% serviceability/satisfactory working condition of fas , routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices , break-down maintenance , maintenance of records/service reports and reporting as and when required , complete up-keeping of the installations (fas) , as specified and as directed by engineer-in-charge as required. for second year (terminal building & technical block (make- edwards , model-io-100
Tender For tender for supply of sensor k type thermocouple for ct 642 , chaff launchers for channel nos 15 and 16 , thermocouple , thermocouple , thermocouple temp sensor pt-46- ekm , alarm annunciator , main instrument for ct 204 , sensor set of 16 nos , multiplexer pcb with input selection , thermocouple xa , kitu sensor , ip-65 weather proof j.b for cakt-02 (no of points-24 , 3 wire , ip-65 weather proof j.b for cakt-06 (no of points-12 , 3 wire , battery temperature monitoring system , diesel exhaust temperature monitoring system , shafting temperature monitoring system
Tender For corrigendum : supply of supply of intelligent multi-criteria photo electric smoke & thermal detector, white colour, suitable , supply of 2-zone gas release fire alarm panel designed for gas suppression systems. it features a 16 , supply of addressable dual- action manual pull station-red in colour, designed for fire alarm systems , supply of sounder with 90 db output at 1 metre distance cum strobe lights with 110 cd as per specifi , supply of dual-action manual abort station - yellow in colour, designed for fire alarm systems. cons , supply of dual-action manual release station -green in colour, designed for fire alarm systems. cons , supply of addressable relay output module with programmable dry contact output for interfacing with , supply of addressable supervised control module for operating sounders/ horns with line monitoring, , supply of addressable monitor module for supervision of potential free contacts such as flow switche , supply of 2c x 1.5 sq. mm fire survival un- armoured cables (300/500 v) with copper conductor, cross- , supply of electric gas release caution sign boards (24 v dc) for approved locations. make: std , system rectification, modification, re-programming & cleaning charges
Tender For comprehensive maintenance of power transformers etc. - -hisar `job work for comprehensive maintenance of power transformers typically includes routine inspections, cleaning, oilanalysis and filtration (if required), elec. testing (insulation resistance, turns ratio, etc.), tightening of connections, bushing maintenance, protection relay checks, minor repairs, and reporting installed at all water works and boosting station at hisar town under the jurisdiction of phesd-1 hisar and all other works contingent thereto.` chargeable to:- a/mtc. water supply scheme hisar town.