Get complete information related to latest Oil Cooler Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oil Cooler Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oil Cooler Tenders.
Tender For supply of set of elastomer sealing rubber for all type of 3 phase locos as per clw specn. no. clw/ms/3/034 alt-6 & clw/ms/10/022, alt-3 . one set consist of 03 items. 99.2 meters as follows: (1) gasket 4lip as per clw/drg.no. 1209-11.406-091 alt-3, qty.=16.2 meters. (2) self gripping sealing rubber as per clw drg. no. 1209-18.406-089 alt 5, qty.=82 meters (for roof hatch 62 meters, for tfp 10 meters, for tm & oilcooler blower 10 meters). (3) self gripping sealing rubber as per clw drg. no.1209-18.406-088 alt-2, qty.=01 meter. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of filter assly. for mr.tm oilcooler ventilator, g9/p7/p5, clw's specn. no. clw/ms/3/012 alt-6 [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of "motor with capacitor for transformer oilcooler for bg ac emu complete with fan, 0.5 hp, 2.5 amp, 240v ac, single phase, capacitor start & capactor run. as per icf specn no. icf/elect/014 rev-a and overall dimension of motor, shaft size, shaft length, location of fixing hole shall be as per drg. no. icf/sk-9-0-606 alongwith latest amendment/alteration if any. capacitor shall be as per icf correction slip 01 of spec icf/elect/014 rev a" [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of tubes and work of insitu retubing as per atc d d - aluminium brass seamless cold drawn tubes , end plate having size of o.d. 267mm, thickness 16.5mm, 190nos. of holes and material s.s. 304 for lube oilcooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 205mm, thickness 32mm, 190nos. of holes and material s.s. 304 for lube oilcooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 330mm, thickness 25mm, 320nos. of holes and material s.s. 304 for working oilcooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 260mm, thickness 40mm, 320nos. of holes and material s.s. 304 for working oilcooler of bfp unitunit no. 3 and 4 gtps. , baffles having size of o.d. 205mm, thickness 04mm both end chamfer and material s.s. 304 for lube oilcooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 25nos. , baffles having size of o.d. 260mm, thickness 04mm both end chamfer and material s.s. 304 for working oilcooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 19nos. , work of complete in situ re tubing of old damaged tube cooler of lube oilcooler of 210mw unit no. 3 and 4 as per atc , work of complete in situ re tubing of old damaged tube cooler of working oilcooler of 210mw unit no. 3 and 4 as per atc ) /bid number : gem/2026/b/7336822 * /dated: 14-04-2026 & & / bid document 1 / 12
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For work of cleaning of lube oilcoolers of coal mills, boiler fans and boiler auxiliaries during aoh/ssd in 210 mw units of khaperkheda tps as and when required basis.
Tender For supply of bolster bush part no 14205051000 , seal kit for roll back cylinder part no 1420202051015 , seal kit for boom lifting cylinder part no 1420202050914 , bush for drive sprocket motor side part no 22203030200 , idler sprocket fixed part no 22203031000 , idler sprocket part no 22203031100 , idler shaft part no 22203031200 , drive sprocket part no 14205050304 , idler wheel part no 14205050305 , verticle roll part no 14205050309 , horizontal roller part no 14205050311 , seal kit steering cylinder part no 14205052109 , spider assembly part no 14206061300 , seal kit for push plate cylinder part no 1420302050914 , element for inline pressure filter 08 part no 08010002 , flange part no 14206060132 , oil seal for fan motor part no 1420404100717 , pillow block bearing part no 14206063900 , relief valve part no 274hpesimp0102 , rear mechanical 6c drive shait part no 14206060600 , middle mechnical 6c drive shaft 142060 part no 14206060700 , front mechanical 6c drive shaft part no 14206060800 , slip ring assy part no 14205050307 , chain tension yoke part no 14205050306 , spider assly bolt hn13671050 part no hhb13672050 , priority unloading valve part no 274hpesimp0101 , twin screen oilcooler part no 14205050405