Tender For design, manufacture, supply, testing, and commissioning of 90 no. of standard gauge cars for inderlok-indraprastha corridor (line-8 extension) of dmrc including training of employers manpower and 35 years camc for these 90 no. standard gauge cars. - design, manufacture, supply, testing, and commissioning of 90 nos. of standard gauge cars for inderlok-indraprastha corridor (line-8 extension) of delhi metro rail corporation ltd. including training of employer’s manpower and comprehensive maintenance of these 90 nos. standard gauge cars as well as depot m&ps, special tools, jigs and fixtures, testing and diagnostic equipment, test benches, material handling equipment etc. for a period of thirty-five years.
Tender For supply of high tensile transition cb coupler for ac locos to rdso spec no 56-bd-07 with amendment no. 1 of september 2010 and amendment no. 2 of september 2016 and to rdso drg. no skdl 3430 alt 8 except item no 24 to 47, and to part drg. nos sk.dl 62724 alt 28, skdl 3119, skdl 2496 alt 6, sk 69508 alt 4, skdl 2494 alt 17, skdl 2495 alt 12 and skdl 890 alt 4. item no 18 (high capacity draftgear) to str 49-bd-08 of june 08 with amendment no. 1 of september 2016. item no 19 (striker block) as per clw drg no 05/3/57/31 alt 3 for modified striker casting, item 20 suspension hook as per rdso drg no skdl 3430 alt 8 are to be supplied in loose condition each set consisting of one no. of each item. note: (1) it should be ensured that 100% of knuckle (item 2 of rdso drg no skdl-3430 alt8) should be checked to pass 10a contour gauge. (2) firm who are approved for high tensile cbc have to arrange / purchase the components / high capacity draft gear from rdso/blw approved sources only, if they are not approved for such components. (3) mpt and dpt to be done for 100% quantity for any cracks during acceptance test, in line with rdso letter no el/3.2.119 (cbc) dated 27.11.2019. [warranty period: 30 months after the date of delivery ]
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperaturegauge, oiltemperaturegauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For bid to ras bid to ras providing of calibration services - mechanical; comparision test of gauge with master gauge calibation of dial gauge magnetic base; nabl labs; lab
Tender For digital cbc height gauge accuracy of gauge -(+/-) 0.2mm, measuring range: 930 to 1130 mm. the material to be supplied in elegantly finished storing and transportation box with carrying handle and with working manual. note: calibration from nabl accredited lab and test certificate to be supplied alongwith the material at the time of supply. accepted make : pie/prasad/ganapathy/aoge or similar as per specification attached. [ warranty period: 24 months after the date of delivery ]
Tender For supply of disposable laboratory items - container for urine, sputum, stool sample collection, leak proof with wide mouth, conical wide bottom & screw cap, 50 ml capacity with label for patient name, ward/opd and registration number, pack size – 1 x 100 , esr disposable pipette with tube, tube 13 x 75 mm clean transparent with graduation at 0.4 ml and 2 ml should allow to fill by air pressure through the rubber piston blood lift up – up to zero level. pipette should be made with transparent polystyrene with graduate d scale 0 to 180-200. it should be fine finished; pack size – 1 x 100 , evacuated blood collection tube with spray dried k2edta with lavender safety closure. it should be made of clear latex free polyethylene terphthalate. size – 13 x 75 mm with 4.0 ml, volume capacity. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified. firm should provide training to technicians/nurses regularly for blood collection. clinical services should be documented by company. pack size – 1 x 100 , sodium citrate evacuated tubes for coagulation test with vacuum (with na. citrate – 0.109 m/3.2% plastic tube made of clear latex free polyethylene terphthalaste with light blue safety closure, 13 mm x 75mm vol. 2.7 ml. batch wise gamma sterilized /pyrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified, firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 ,, evacuated tubes for silica-clot activator/silicon coated made of clear latex polyethylene terphthalate with safety closure 13 x 75 mm vol. 4.0 ml. it should be iso and us-fda/ce certified. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 , blood collection needle 21 or 22 gauge with cap for evacuated tube. it should be iso and us-fda/ce certified and gamma sterilized certificate. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 , evacuated tube needle holder; pack size – 1 x 5 , "clot activator for serum with gel 3.5 to 4 ml, 13 x 75 mm 1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5. the quantity of additives in the respective tube should be as per nccls/clsi guidelines. 6. should provide different color coding cap for different additives.7. the tube should contain a label for noting the patient’s details8. manufacture should provide iso and us-fda/ce certification 9. expiry dates should be printed on blood collection tubes. blood collection should be gamma sterilized. paramedical to be trained10. batch wise sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to the technician/nurses regularly, clinical services should be documented by the company (1 x 100)11. adequate/combustion data to prove that it is safe for the environment incineration pack size (1x100)" , "clot activator for serum with gel 5-6 ml, 13 x 100 mm1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5