Web Analytics Made Easy - StatCounter

Oil Temperature Gauge Tenders

Get complete information related to latest Oil Temperature Gauge Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oil Temperature Gauge Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oil Temperature Gauge Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :44780442 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For design, manufacture, supply, testing, and commissioning of 90 no. of standard gauge cars for inderlok-indraprastha corridor (line-8 extension) of dmrc including training of employers manpower and 35 years camc for these 90 no. standard gauge cars. - design, manufacture, supply, testing, and commissioning of 90 nos. of standard gauge cars for inderlok-indraprastha corridor (line-8 extension) of delhi metro rail corporation ltd. including training of employer’s manpower and comprehensive maintenance of these 90 nos. standard gauge cars as well as depot m&ps, special tools, jigs and fixtures, testing and diagnostic equipment, test benches, material handling equipment etc. for a period of thirty-five years.

Central Government/Public Sector

CTN :44800803 Due date: 17 Apr, 202617 Apr, 2026 NA
Tender For supply of high tensile transition cb coupler for ac locos to rdso spec no 56-bd-07 with amendment no. 1 of september 2010 and amendment no. 2 of september 2016 and to rdso drg. no skdl 3430 alt 8 except item no 24 to 47, and to part drg. nos sk.dl 62724 alt 28, skdl 3119, skdl 2496 alt 6, sk 69508 alt 4, skdl 2494 alt 17, skdl 2495 alt 12 and skdl 890 alt 4. item no 18 (high capacity draftgear) to str 49-bd-08 of june 08 with amendment no. 1 of september 2016. item no 19 (striker block) as per clw drg no 05/3/57/31 alt 3 for modified striker casting, item 20 suspension hook as per rdso drg no skdl 3430 alt 8 are to be supplied in loose condition each set consisting of one no. of each item. note: (1) it should be ensured that 100% of knuckle (item 2 of rdso drg no skdl-3430 alt8) should be checked to pass 10a contour gauge. (2) firm who are approved for high tensile cbc have to arrange / purchase the components / high capacity draft gear from rdso/blw approved sources only, if they are not approved for such components. (3) mpt and dpt to be done for 100% quantity for any cracks during acceptance test, in line with rdso letter no el/3.2.119 (cbc) dated 27.11.2019. [warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :44801583 Due date: 29 Apr, 202629 Apr, 2026 NA
Tender For supply of item no. 10: m9491176012- lab instr: fild calibratr: hart comunicatr: , item no. 20: m9722200040: camera: infr therm image: 1280x1024, 3.5" : , item no. 30: m9491966018- lab instr. : digital press meter: 0- 400bar: , item no. 40: m9491966005: lab instr. : digital test gauge 0-20ksc:

State Government

CTN :44798192 Due date: 28 Apr, 202628 Apr, 2026 1.97 Lacs
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge

CTN :43742414 Due date: 10 Apr, 202610 Apr, 2026 NA
Tender For bid to ras bid to ras providing of calibration services - mechanical; comparision test of gauge with master gauge calibation of dial gauge magnetic base; nabl labs; lab

CTN :44160226 Due date: 05 May, 202605 May, 2026 NA
Tender For corrigendum : rate contract for supply of surgical items - abdominal drainage kit, all sizes, abdominal sponge (laparotomy pad), 25 cm x 25 cm x 12 ply, sterile, abdominal sponge (laparotomy pad), 25 cm x 40 cm x 12 ply, sterile, abdominal sponge (laparotomy pad), 40 cm x 40 cm x 12 ply, sterile, abdominal sponge (non-sterile) with radiopaque thread and long loop 30 cm x 30 cm, 12 ply, abdominal sponge with radiopaque thread 20 cm x 20 cm, absorbable hemostatic gelatin sponge 7 cm x 5 cm x 1 cm, absorbable hemostatic gelatin sponge 8 cm x 3 cm (anal use), absorbable hemostatic sheet (oxidized regenerated cellulose) 5.1 cm x 10.2 cm, absorbable hemostatic sheet (oxidized regenerated cellulose) 5.1 cm x 7.6 cm, absorbent adhesive surgical dressing 10 cm x 20 cm, sterile, absorbent cotton roll, acrylic polishing bur, acrylic trimming bur, act (activated clotting time) test tubes compatible with existing equipment, adenoid curette, adhesive island dressing (20 cm x 10 cm), adhesive island dressing (6 cm x 8.3 cm), adhesive sterile draping sheet 135 cm x 200 cm, adhesive tape 2 inch, paper (microporous), adhesive tape 3 inch, cloth, adhesive tape 3 inch, foam, adhesive tape 3 inch, silk cloth base, adhesive tape 3 inch, woven fabric, hypoallergenic, adhesive with applicator 2-octyl cyanoacrylate, adson forceps pediatric, adult triple lumen cvc kit, 7f, 15/20 cm, advanced iv set with air stop & prime stop, pvc-free & dehp-free, advanced iv set with air stop, prime stop & back check valve, alcohol swab, 70% isopropyl alcohol, alginate impression material, ampoule breaker/opener, multifunctional, anal fistula probe, all sizes, angio kit (push-pull, antegrade cardioplegia cannula-aortic root type, 12 gauge, antegrade cardioplegia cannula-aortic root type, 14 gauge, antegrade cardioplegia cannula-aortic root type, 16 gauge, antegrade cardioplegia cannula-aortic root type, 18 gauge, antegrade cardioplegia cannula a" aortic root type, 12 gauge, antegrade cardioplegia cannula a" aortic root type, 14 gauge, antegrade cardioplegia cannula a" aortic root type, 16 gauge, antegrade cardioplegia cannula a" aortic root type, 18 gauge, antegrade cardioplegia coronary ostial cannula, 45 angled, 10 fr, antegrade cardioplegia coronary ostial cannula, 45 angled, 12 fr, antegrade cardioplegia coronary ostial cannula, 45 angled, 8 fr, antegrade cardioplegia coronary ostial cannula, 45a angled, 10 fr, antegrade cardioplegia coronary ostial cannula, 45a angled, 12 fr, antegrade cardioplegia coronary ostial cannula, 45a angled, 8 fr, antegrade cardioplegia coronary ostial cannula, 90 basket tip, 10 fr, antegrade cardioplegia coronary ostial cannula, 90 basket tip, 12 fr, antegrade cardioplegia coronary ostial cannula, 90 basket tip, 8 fr, antegrade cardioplegia coronary ostial cannula, 90a basket tip, 10 fr, antegrade cardioplegia coronary ostial cannula, 90a basket tip, 12 fr, antegrade cardioplegia coronary ostial cannula, 90a basket tip, 8 fr, antegrade three-channel cardioplegia cannula, anterior cervical plate system, anterior-posterior nasal packing catheter for epistaxis, anteriora"posterior nasal packing catheter for epistaxis, antimicrobial barrier dressing, gelatin-chitosan with f10, multiple sizes, antimicrobial dressing for catheter sites, gelatin-chitosan, 2.5 cm-4 mm, antimicrobial healing kit with hocl solution, 10a-10 cm dressing, antimicrobial surgical site dressing, gelatin-chitosan, multiple sizes, aortic arch cannula (straight/angled, with/without metal tip), 10 fr, aortic arch cannula (straight/angled, with/without metal tip), 12 fr, aortic arch cannula (straight/angled, with/without metal tip), 14 fr, aortic arch cannula (straight/angled, with/without metal tip), 16 fr, aortic arch cannula (straight/angled, with/without metal tip), 18 fr, aortic arch cannula (straight/angled, with/without metal tip), 20 fr, aortic arch cannula (straight/angled, with/without metal tip), 22 fr, aortic arch cannula (straight/angled, with/with

Central Government/Public Sector

CTN :44773167 Due date: 15 Apr, 202615 Apr, 2026 NA
Tender For digital cbc height gauge accuracy of gauge -(+/-) 0.2mm, measuring range: 930 to 1130 mm. the material to be supplied in elegantly finished storing and transportation box with carrying handle and with working manual. note: calibration from nabl accredited lab and test certificate to be supplied alongwith the material at the time of supply. accepted make : pie/prasad/ganapathy/aoge or similar as per specification attached. [ warranty period: 24 months after the date of delivery ]

State Government

CTN :44720345 Due date: 29 Apr, 202629 Apr, 2026 4.40 Crore
Tender For supply of disposable laboratory items - container for urine, sputum, stool sample collection, leak proof with wide mouth, conical wide bottom & screw cap, 50 ml capacity with label for patient name, ward/opd and registration number, pack size – 1 x 100 , esr disposable pipette with tube, tube 13 x 75 mm clean transparent with graduation at 0.4 ml and 2 ml should allow to fill by air pressure through the rubber piston blood lift up – up to zero level. pipette should be made with transparent polystyrene with graduate d scale 0 to 180-200. it should be fine finished; pack size – 1 x 100 , evacuated blood collection tube with spray dried k2edta with lavender safety closure. it should be made of clear latex free polyethylene terphthalate. size – 13 x 75 mm with 4.0 ml, volume capacity. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified. firm should provide training to technicians/nurses regularly for blood collection. clinical services should be documented by company. pack size – 1 x 100 , sodium citrate evacuated tubes for coagulation test with vacuum (with na. citrate – 0.109 m/3.2% plastic tube made of clear latex free polyethylene terphthalaste with light blue safety closure, 13 mm x 75mm vol. 2.7 ml. batch wise gamma sterilized /pyrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified, firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 ,, evacuated tubes for silica-clot activator/silicon coated made of clear latex polyethylene terphthalate with safety closure 13 x 75 mm vol. 4.0 ml. it should be iso and us-fda/ce certified. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 , blood collection needle 21 or 22 gauge with cap for evacuated tube. it should be iso and us-fda/ce certified and gamma sterilized certificate. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 , evacuated tube needle holder; pack size – 1 x 5 , "clot activator for serum with gel 3.5 to 4 ml, 13 x 75 mm 1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5. the quantity of additives in the respective tube should be as per nccls/clsi guidelines. 6. should provide different color coding cap for different additives.7. the tube should contain a label for noting the patient’s details8. manufacture should provide iso and us-fda/ce certification 9. expiry dates should be printed on blood collection tubes. blood collection should be gamma sterilized. paramedical to be trained10. batch wise sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to the technician/nurses regularly, clinical services should be documented by the company (1 x 100)11. adequate/combustion data to prove that it is safe for the environment incineration pack size (1x100)" , "clot activator for serum with gel 5-6 ml, 13 x 100 mm1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5

CTN :44455226 Due date: 06 Apr, 202606 Apr, 2026 NA
Tender For corrigendum : supply of timer , tem controller , oven , decompression tool , gauge , data logger , thermometer , protractor , probe , hot bonder , thermo couple , controller , tds meter , weighing balance , machine , megger , digital force gauge , infrared thermometer , lcr meter , force gauge , lux meter , micrometer , trammel bar , feeler gauge , ground fault tester , inspection machine , residual field indicator , gauss meter , intensity meterdyeglo , uve lux meter , uv light meter , visible light meter , aerocheck , tam panel psm5 , hoffmanntam panel , surface plate cast iron , protractor mount , fuel quantity test adaptor kit , dmc tool kit , elt tester , reflectometer , mx6 hybrid multi gas detector , ulb tester , analyser , tester , lrra tester , altimeter , clampmeter , air data test set , milli ohm meter , calibrator , sound level meter , vacuum gauge , static charge meter , surface resistivity meter , portable eddy current machine , hydraulic tank , gauge assy push pull , exting fire test , dynamometer , fire extinguisher system , ext fire test , calibration standard , reference standard , calibration block , safety lock actuator cargo , device check vapor seal , test set engine bleed , cart pressure , ground test motor , tensio meter , our side micrometer , bevel protector , dynamometer safety , tons gauge , dial depth gauge , dial test indicator , mechanical force gauge , hygrometer

CTN :44740619 Due date: 23 Apr, 202623 Apr, 2026 NA
Tender For supply of es1020k-psa-8605 pcb b1 , es1020k-0-15 b 2 pcb for probe , es1020k-0-15b 21 ststor resilient stator for pump , es1020k-0-15b 22 rotor helical rotor pump , es1020k-5p 1 pump with motor foun model ces 5 50 3hp 380v 3 60hz 740rpm , es1020k-0-15a 4 set of gasket electro pneumatic valve , es1020k-0-15b 3 level control pcb , es1020k-0-15b 4 intconn cable b w probe panl , es1020k-0-15c 6 1 auto manual knob , es1020k-0-15d 2 pneumatic cylinder , es1020k-0-15pm 4 pcb e , es1020k-2 filter candle , es1020k-2-5a 2 coalescer stock , es1020k-2-5a 3 guide cylinder , es1020k-2-5a 5 pressure relief valve , es1020k-2-5a 6 test cock , es1020k-52-5b 2 pcb for probe , es1020k- 2-5b 3 level control pcb , es1020k-2-5b 5 on off switch , es1020k-2-5b 6 mode switch , es1020k-2-5b 7 indication lamp led , es1020k-2-5c 10 coupling pad , es1020k-2-5c 12 front bearing for motor , es1020k- 2-5c 13 bearing for motor rear , es1020k-2-5 c 14 gland packing for pump , es1020k-2-5 c 6 retaining ring , es1020k-2-5-5 d 2 pneumatic cylinder , es1020k- 25 front bearing for pump , es1020k-26 rear bearing for pump , es1020k-5-pm-10 buzzer , es1020k-dsp-8607 pcb g display board , es1020k-i b 25 and 26 bearing for pump no 6005 and 6304 one set , es1020k-idm- 8604 pcb c , es1020k-pre-8601 pcb d , es1020k-0-15a 14 auto airvent vale , es1020k-0-15a 15 manual airvent valve , es1020k-0-15a 2 coalescer disc stack , es1020k-1b 29 o ring , es1020k-1b 30 coupling pads , es1020k-2-5a 13 pressure gauage , es1020k-2-5 c 11 o ring for pump , es1020k-5a 1 obs filter candles , es1020k-5a 11 pressure gauge compound gauge , es1020k-5b 21 obs resilient stator pump , es1020k-5b 22 obs helical rotor pump , es1020k-5-a-24 dry running protection , es1020k-5-a-4 baffl , es1020k-5- pm-1 purimeter , es1020k-idm8604 obs pcb c purimeter , es1020k-mcbi complete measuring cell bi card , es1020k-oc 1 optical glass tube for optical cell , es1020k-ocm e pcbe pcb e , es1020k-psa8601 pcb d , es1020k-psa8604 pcb c , es1020k-psa8605 pcb b //bid details 2 / 44
 Loading, Please wait...

Connect us via What's Up