Web Analytics Made Easy - StatCounter

Ondulator Scrap Tenders

Get complete information related to latest Ondulator Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ondulator Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ondulator Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40026621 Due date: 27 May, 202527 May, 2025 NA
Tender For supply of visual indication of tm current with push button/toggle switch for wap-4 & wag-7 locomotiv es having gear ratio 23:58 (qty 36nos) & 16:65 (qty 60 nos) respectively as per rdso modification sheet el/ms/ 0339 rev'1' dated 04.04.2014 [ warranty period: 30 months after the date of delivery ]

State Government

CTN :40071789 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above

CTN :40222106 Due date: 02 Jun, 202502 Jun, 2025 42.37 Lacs
Tender For supply of electrical materials for the repair and maintenance of street lights as per the boq - t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder, led driver 50w bis certified, led mcpcb plate 50w, led mcpcb plate 100w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10 ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolyt

Central Government/Public Sector

CTN :40231617 Due date: 19 May, 202519 May, 2025 NA
Tender For supply, installation and commissioning of audio visual indication in banker loco in case of b p dropping as per the scope of work enclosed. to be procured from past proven sources of indian railway. [ warranty period: 30 months after the date of delivery ]

CTN :40151688 Due date: 19 May, 202519 May, 2025 NA
Tender For supply of class b & c surge protection device (spd) -type i & ii with visual indication and po tential free contact to remote monitoring as per specification no. rdso/spn/165/2012 ver 3.0 or latest and iec standard 61643 for single line 230v ac application with handling lightning surges of 10/350 microseco nds and switching surges of 8/20 microseconds .one set consists of 3 nos. of spd (2 no. of b class (l-n, n-e ) and one no. of c class (l-n) all enclosed in a box with kema or vde certified as per latest iec 61643-11-2 011 standard. class b &c surge protection device required with three modules only.installation of class b & c surge protection should be as per the tan no:- sts/e/tan/3006, version- 3.0 ; dated:- 08.01.2025 (tan specs attached as annexure.) [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up