Get complete information related to latest Operator Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Operator Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Operator Panel Tenders.
Tender For w acting for and on behalf of the president of india invites e-tenders against tender no e-73-dyceekgpw-cbc-26-27 closing date/time 01/07/2026 15:00 hrs. bidders will be able to submit their original/revisedbids upto closing date and time only. manual o ers are not allowed against this tender, and any such manual o erreceived shall be ignored.1. nit headername of workupgradation of cbc overhauling section and corrosion repair shop of wagonrepair shop, kharagpur workshop.bidding typenormal tendertender typeopenbidding systemsingle packet systemtender closing datetime01/07/2026 15:00date time of uploadingtender09/06/2026 16:38pre-bid conferencerequirednopre-bid conference datetimenot applicableadvertised value 2402108.76tendering section elegenbidding style single rate for tender bidding unitabove/below/parearnest money (rs.) 48100.00validity of offer ( days) 60tender doc. cost (rs.)0.00period of completion 18 monthscontract type works - general contract category expenditurebidding start date 17/06/2026are jv allowed to bid nonumber of jv memberallowed0are consortium allowedto bidnonumber of consortiummember allowed0ranking order for bidslowest to highest expenditure typecapital (works)2. schedules.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () a-cost of supply of material for electrical work1712792.421a12.00numbers383500.00 767000.00 at par 767000.00description:- supply of incoming 1x 630a,4p, 50ka mdo type microprocessor based acb withipr1+ release & outgoing (i)2 x 320a,4p, 36ka thermal magnetic release with adjustable thermal &fixed magnetic mccb (ics=100%icu),(ii)2 x 200a,4p, 36ka thermal magnetic release withadjustable thermal & fixed magnetic mccb (ics=100%icu),(iii)4 x 100a,4p, 36ka thermal magneticrelease with adjustable thermal & fixed magnetic mccb (ics=100%icu) tted in lt panel box14swg crca sheet powder coated 4way cu busbar of suitable rating, indicator lamp, digitalmultifunction meter & all other accessories. mccb & acb make:- havellls/ lk/ schneider/siemens.2a210.00numbers 400.02 4000.20 at par 4000.20description:- supply of mcb metal enclosure 4 pole3a380.00numbers 413.00 33040.00 at par 33040.00description:- supply of pyramid insulator as per drawing4a470.00numbers 531.00 37170.00 at par 37170.00description:- supply of pin type insulators as per drawing.5a550.00numbers1121.00 56050.00 at par 56050.00description:- supply of gi-angle (40 x 40 x 06 mm) bracket 4 way with porcelain insulator as perdrawing suitable for overhead light.6a610.00numbers 248.98 2489.80 at par 2489.80description:- supply of mcb metal box 2 pole7a720.00numbers1323.96 26479.20 at par 26479.20description:- supply of 16/20/25a power unit (containing 4 module plate, starter, socket and plug)for ac unit.8a85.00numbers11434.20 57171.00 at par 57171.00description:- supply and testing of oscillating type bldc pedastal fan, 230 v,400 mm sweep,multi speed, remote/button controlled make- atomberg, havells, crompton, bajaj, usha, orient.9a9 150.00 metre1150.50 172575.00 at par 172575.00page 1 of 18run date/time: 09/06/2026 16:38:46kgp-workshop-electrical/south eastern rlytender documenttender no: e-73-dyceekgpw-cbc-26-27closing date/time: 01/07/2026 15:009description:- supply of hot dip galvanized 2mm thickness perforated cable tray of size 300 mmwidth and 50 mm height and complete accessories as per is, ie rules and site requirement10a10 50.00 metre 575.25 28762.50 at par 28762.50description:- supply of cable trays 2mm thickness size 100 x 50 mm gi, perforated (rmt) withcover complete and as per is, ie rules and site requirement.11a11 10.00numbers 180.54 1805.40 at par 1805.40description:- supply of combined switch socket box - 16 a, capton 5-in-1 combined switch andsocket with isi mark,as per is:3854 or latest12a122.00numbers34700.26 69400.52 at par 69400.52description:- supply of 4 pole mccb ,release range (80-200)a, breaking capacity 36 ka,microprocessor release with inbuilt earth pr
Tender For supply of control panel_sensor_ magnet make hendefsan suitable for onida elevator_party shall provide detail drawing along with panel and shall install as standby system , cop_car operatorpanel_make hendefsan suitable for onida elevator , limit tvs cherry micro switch suitable for onida elevator , drive make_hpmont or fuji electric suitable for onida elevator za101a0002de and shall install in control panel as standby system , lop_landing operatorpanel_ g_5 lop with digital display make hendefsan suitable for onida elevator , guide shoe_heavy type make onida elevator_guide shoe_9 mm heavy type , elevator travelling cable 0.5 mm make_umesh suitable for onida elevator
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For corrigendum : supply of siemens make aop 30 sinamics g130 operatorpanel of geho vfd for silo ahp & allen bradley make vfd at erh for chp at 1 x 800mw unit-8 gsecl-wtps
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For auction sale of rolling stock - pl no 98111073 condemned and unserviceable icf bg 8 wheeler coaches no. [1] special repair wgscn 056327 [2] special repair wgscn 054040 [3] special repair rt 900066 [4] special repair gslrd 046712 [5] special repair gs 066410 [6] special repair wgaccn 046111 [7] special repair wgaccn 046139 with all available ferrous-non ferrous electrical fittings with wires, lights, fans, switches, mobile chargers, batteries, battery boxes, wash basins, bio tanks, dust bins, wooden items, ss and aluminium water tanks, porcelain/ss commode/ inlay pans, wall protectors, main doors and lugguage doors, 25kva ac coach under slung inverters and its panels, power cables, pre cooling transformer, wra pumps, power panel, rmpu and control panels, change over rotor switches, rru, bp fp gauge, smoke and heat detection alarm system and there on. rate per number should be quoted. advice note no. [1] 073349-26-08907, dt 18.06.26 [2] 073349-26-08904, dt 18.06.26 [3] 073349-26-08905, dt 18.06.26 [4] 073349-26-08909, dt 18.06.26 [5] 073349-26-08908, dt 18.06.26 [6] 073349-26-08903, dt 18.06.26 [7] 073349-26-08906, dt 18.06.26. approx. weight of the coaches is 206.028 mts. on as is where is condition. note: [1] cutting permitted to cut the coach into two pieces [center cut]. [2] crane loading permitted. [3] coach in grounded condition without bogie complete set(location: mettu line nearby ipf colony office goc)
Tender For annual maintenance contract of installed e&m equipments in central drug standard control organization, gothapatna, bhubaneswar for financial year 2026-27. - & minor repairs of cctv & including, & minor repairs of kone lift i/c, (standard deviation colour matching), (standard deviation colour matching), (t.c.). manufactures word mark/, (unified glare rating) < 19, flicker, / 6500°k (as per ansi bin), sdcm, /6500°k (as per ansi bin),sdcm, <3,, <5, maximum power consumption, >85%, input voltage: 140-270 volt ac,, >85%, operating voltage ac 140-270, >85%, operating voltage ac 140-270, >85%,thd < 10% as per iec 61000-, 1 2,22,718.00 job 2,22,718.00 mr, 1 no 13 passenger lift,, 1.5 sq. mm frls/hffr, pvc, 10% , p. f.≥0.95, ip20, cri ≥80, ugr, 10.1 18 watt 10 618.00 each 6,180.00 mr, 10322 with driver as per the, 11.1 36 watt 10 2,103.00 each 21,030.00 mr, 12 13,877.00 month 1,66,524.00 mr, 12 16,961.00 month 2,03,532.00 mr, 12 21,586.00 month 2,59,032.00 mr, 12 24,086.00 month 289032 mr, 12 24,128.00 month 2,89,536.00 mr, 12 31,890.00 month 382680 mr, 12 4,490.00 month 53,880.00 mr, 12 53,452.00 month 6,41,424.00 mr, 125 kva dg set with amf and, 15u rack 1 13,330.00 nos 13,330.00, 2 x 6 sockets 16a power distribution, 2.5 kv with short & open circuit, 3-2, p. f.≥0.95, ip-66,ik-10, cri >70,, 39.23.3, 4000°k/ 5700°k /6500°k (as per ansi, 61000-4-5, driver efficiency, 70% of initial lumen maintained till life, 70% of initial lumen maintained till life, 90°c)., 90°c)., above 90°c)., aluminium body including trim, aluminium body with driver as per the, and earthing etc. as required with, annual comprehensive maintenance, annual comprehensive, maintenance, annual comprehensive, maintenance, approved by engineer-in-charge as, approved by engineer-in-charge as, approved by engineer-in-charge as, as required, as required., at gothapatna as required, attached & following staff., basis as per terms & conditions, basis) including servicing, preventive, bin), sdcm (standard deviation, bis standard complete in all respect, bis standards and trade mark, body material with pmma and, cable and earthing etc. as required, cable and earthing etc. as required, cables, nvr, switch, cctv camera,, cct 3000°k / 4000°k / 5700°k, cdtl building etc. as reqd., centigrade, internal surge protection of, certificate (t.c.). manufactures word, circuitry) of minimum 50000 burning, colour matching) <3,, commissiong of pa, rectification and, comprehensive and repair, comprehensive and repair, comprehensive and repair, condition at cdtl office building etc, contract (as inspection on monthly, copper conductor single core cable, day electrical complaints, complaint, distribution pane, 250 kva substation,, down lighter (round/ square/, driver & electrical circuitry), of, dsr-25, efficacy ≥105 <120 lm/watt) supplying, ends , cct 3000°k / 4000°k / 5700°k, ends as per lm80 extrapolation ies, entire lift , etc in cdtl office building, etc in cdtl office at gothapatna as, extrapolation ies tm-21-11 report,, fixture shall be confirming to relevant, fixture shall be of relevant bis, fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., free, (flicker should be below 5 %), life, frequency 50/60 hz, operating temp, general shift) at cdsco on monthly, hours with70% of initial lumen, housing such that led, housing such that led junction, housing such that led junction, i/c external connections with 1.5, in all respect i/c external connections, inspection on monthly basis) including, inspection on monthly basis) including, insulated copper conductor single core, insulated copper conductor single core, internal surge protection of 2.5 kv with, ip surveillance systems i/c maintance, ip20, cri ≥80 , ugr (unified glare, junctiontemperature shall not rise, knocked-down condition (ckd) shape,, led panel light 2x2 ft. (system lumen, lenses for beam angle asper iesna, life time (led, driver &
Tender For providing of facility management services - lumpsum based - industrial; repair and annual maintenance contract of abb make dc drive panel and 1750 centrifugal machine ac panel; consumables to be provided by buyer
Tender For corrigendum : supply of servo amplifier module , servo amplifier alpha i ps 26-b , ac servo motor alpha i s4 5000-b , fanuc pc board with ic part no a02b-0303-c205 , fanuc separate detector interface unit , fanuc 8.4 lcd display , fanuc cable for 8.4 lcd display , fanuc machine operators panel , fanuc servo amplifier , fanuc fan adapter pcb