Get complete information related to latest Operator Station Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Operator Station Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Operator Station Tenders.
Tender For corrigendum : electrical works for revamping of the high tension ht incomer panel and ct, pt and metering cubicle at jipmer, urban health centre juhc -kuruchikuppam
Tender For corrigendum : execution of the following works at spices board, palarivattom, kochi. sh. (1). providing 2c plus t rmu equipped with frtu, 11 kv lbs metering panel, 11 kv ht panel along with ht cabling works etc . (2) replacement of existing old 25 kva diesel generator set with new 250 kva (cpcb iv plus) compliant diesel generator set and allied works.
Tender For supply of lt panel consisting with 4-pole draw out acb 1000a, 50ka, microprocessor based sr18g, mdo type-02 nos as incoming, acb 1000a, 50ka, microprocessor based sr18g, drawout type-01 nos as bus coupler with 4 pole 400a 50-56ka microprocessor based mccb-05 nos, 4 pole 250 a 36-37ka microprocessor based mccb-05 nos and 4 pole 100a 25ka microprocessor based mccb-02 nos as outgoing with suitablecu. busbar metering voltmeter, ammeter, energy meter on incoming side and ammeter with selector switch, hrc back up fuse in outgoing side and protective circuit & sheet steel enclosure, appropriate spreader kink for mccb and mechanical/electrical interlocking for acb with necessary item for seal the cable entry andoutgoing point. ]
Tender For supply of floor mounted outdoor type lt distribution panel with tpn cu bus bar and the following items: incoming: 2 nos. 400a 36ka 4 pole mccb, outgoing: 2 nos. 250a 36ka 4pole mccb, 2 nos. 100a 36ka 4pole mccb, 1 no. 63a 25ka 4pole mccb & 1 no. 63a 4 pole rccb. the lt panel should be complete with internal wiring, metering arrangement and all accessoriesas. the panel shall conform to description no. ser/elec/gs/description/lt panel/1/rev-2/june 2025.(size wxhxd - 1600 mm x 1800 mm x 600 mm) the minimum clearance to be maintained for enclosed indoor air insulated bus bars shall be as follows: phase to earth 26 mm minimum & phase to phase 32 mm minimum. the complete panel should be oem factory made as per latest is specification. all major components should be of same manufacturer as that of panel. [ warranty period: 30 months after the date of delivery ] ]
Tender For providing metering panels in place of damaged panel boards in snc shops and new panel boards in sub way shops at smc area in esd-south,tirumala
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh
Tender For supply, installation, testing and commissioning of ht metering panel box, 3 35 sq. mm 11 kv ht cable, jointing kit and ttb box for lt to ht load extensionat manakalav pump house
Tender For procurement of electrical spares and consumables for 220 kv and 33kv switch yard at khodri power station - 245 kv lightening arrester, discharge current 10ka, frequency 50 hz,pressure relief class 40 ka(rms), long duration discharge class 3, m.c.o.v. 56 kv, make: oblum electrical industries pvt. ltd. /cg power and industrial solution ltd. or eq make as approved by engineer in charge., 145 kv lightening arrester outdoor type ,suitable for 145kv system voltage , discharge current 10ka, freq. 50 hz, high current impulse (4/10 s) 100 ka, rated lightning impulse withstand voltage 1.2/50 s - 650 kvp, polymer based (single phase) make-oblum electrical industries pvt. ltd. /cg power and industrial solution ltd,/ htachi / siemens india ltd or eq make as approved by engineer in charge., auxiliary switch (stack) 5no + 5nc, 220v, dc, make: crompton, hitachi or eq make as approved by engineer in charge for 220kv cgl make sf6 circuit breaker., surge monitor/surge counter with leakage current meter suitable for 220 kv lightening arrestor , make: cg power and industrial solution ltd./ oblum electrical industries pvt. ltd., 33kv ct indoor type , 3 core, 15va each, ratio 650-350/1 a + 1a , class 0.2s(2 core metering) & 5p10 (protection), str: 25ka for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge., 33kv ct indoor type, 3 core, 15va each, ratio 300-150/1 a + 1a , class 0.2s( 2 core metering) & (5p10 protection, str: 25ka, for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge, control motor, type c21, 2.6 a, 230v ac/dc, o/p 0.3kw, sr. no: 042-901, m/y 03/08, 750/ min. make: kpt shirol or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 7no+6nc (stack), 250 volt dc, make: crompton, hitachi or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 8no+ 8nc, 220v, dc, (motor drive ). make: abb/ hitachi or eq make as approved by engineer in charge for 245 kv, abb make isolator., 220 v, dc, close or trip-1 coil ( part no. exin - 400834 - r9)make: abb/hitachi or eq make as approved by engineer in charge for 145kv, abb make sf6 breaker., rectifier 15 a, 220 v, ac (part no. 1hyn-450040p1 ) make: abb/ hitachi or eq make as approved by engineer in chargefor 245kv, abb make isolator, mcb (2 pole,3a, 220v, dc ), over current earth fault relay, mc61a-nx, cat no : mc61anx2200, make: l&t electrical & automation, or eq make as approved by engineer in charge for 33kv sf6 braeker., 33kv busbar support insulator (epoxy) . make: universal engg. corporation,star electrical engg. works or eq make as approved by engineer in charge.(as per sample), epoxy bushing/ fixed contact of "r","y" &"b" phase bottom side for 33kv cgl make panel (as per sample), epoxy bushing/ fixed contact "r","y" &"b" phase top side for 33kv cgl make panel (as per sample), ratech wheel of 33kv sf6 breaker, cgl make, flexible contact of 33kv sf6 breaker finger, cgl make (as per sample), silica gel blue crystal in mesh size of 15 mm to 35 mm duly packed in poly lined moisture proof m s drums/carton, heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 185 mm 33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- , 185 mm 33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., p g clamp deer/panther for 220 kv conductor, p g tclamp deer/ zebra, for 220 kv conductor, p g clamp deer/ trantulla for 220 kv conductor, p g clamp tarantula/ trantulla for 220 kv conductor, p g clamp deer/deer for 220 kv conductor, p g clamp made of aluminum-alloy suitable for zebra to trantulla conductor with 4 nos bolt - n
Tender For supply of wiring for light point fan point exhaust fan point call bell point with 1.5 sq.mm , earth wire , supplying and drawing following sizes of pvc conduit as required 1.5mm , modular plate , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate , supplying and fixing modular blanking plate on the existing modular plate , supplying and fixing following size , 3 module 100mmx75mm , 4 module 125mmx75mm , 6 module 200mmx75mm , 8 module 125mmx125mm , 12 module 200mmx150mm , supplying and fixing suitable size gi box , 15x16 amps , a exhaust fan of all sizes. , modular plate and cover in front on surface or in recess , providing and fixing 25 a , mcb distribution board , single pole 6 to 32 amp , single pole and neutral 6 to 32 amp , single pole and neutral 63 amp , triple pole and neutral 32 amp. , 63 a tpn mcb 10 ka c curve , mcb db complete etc as required , 32 a 415 v c curve tp mcb , 600 mm x 600 mm x 6 mm thick watering pipe of 2.7 meter long etc. , providing and fixing 25 mm x 5 mm gi , providing and fixing 6 swg dia gi , led batten light 40 watt , ceiling fan 3 star rated with voltage range 90 v to 300 v 1200 mm , 300mmx12 inch sweep exhust fan , 50 w flood light 50 watt , sitc of building distribution panel indoor , 160 a 36ka fpmccb , aluminium bus bar 200 amp set of 4 strips 18 inch , digital metering devices , supplying and laying of following size dwc hdpe pipe isi marked along with all accessories , supplying and laying of one number pvc insulated and pvc sheathed , supply and making end termination with brass compression gland and aluminium lugs , 2.5 kva sine wave inverter input 1 phase 3 wire and output 1 phase 3 wire with 2 nos of 12 v 200 ah battery , hot dipped galvanised iron cable tray 100 mm width x 50 mm depth x 1.6 mm thickness