Tender For work for installation of electrical equipments laying of 11 kv grade xlpe u g cable and 1.1 kv grade copper control cable and other allied work for construction of new 33 11 kv sub-station at s l hitech infrapark near belmuri under tarakeswar divn
Tender For corrigendum : procurement of air conditioning system for ntpc singrauli project - supply- ac and ventilation system -air cooled condensing unit , supply- ac and ventilation system -air handling unit -ahu , supply- ac and ventilation system -strip heaters , supply- ac and ventilation system -pan humidifier , supply- ac and ventilation system -copper refrigerant piping -suction line , supply- ac and ventilation system -copper refrigerant piping -liquid line , supply- ac and ventilation system -refrigerant gas , supply- ac and ventilation system -gss duct sheet - 24 g - air conditioning system , supply- ac and ventilation system -gss duct sheet - 22 g - air conditioning system , supply- ac and ventilation system -gss duct sheet - 20 g - air conditioning system , supplyac and ventilation system -gss duct sheet - 18 g - air conditioning system , supply- ac and ventilation system -volume control damper , supply- ac and ventilation system -fire damper , supply- ac and ventilation system -motorised actuator for fire damper , supply- ac and ventilation system -grills diffusers , supply- ac and ventilation system - accoustic insulation , supply- ac and ventilation system -thermal insulation , supply- ac and ventilation system -fine filter , supply- ac and ventilation system -dp switch , supply- ac and ventilation system -fresh air fan assembly , supplyac and ventilation system -cassette ac unit - 4 tr , supply- ac and ventilation system -cassette ac unit - 3 tr , supply- ac and ventilation system -cassette ac unit - 2 tr , spares- ac and ventilation system -v belts for blower , spares- ac and ventilation system -ahu blower bearings of each type , sparesac and ventilation system -blower motor bearing , spares- ac and ventilation system -pre filter for ahu , spares- ac and ventilation system -fine filter for ahu , spares- ac and ventilation system - electrical actuator , spares- ac and ventilation system -dp switch , spares- ac and ventilation system -relative humidity sensors , spares- ac and ventilation system -geyserstat , spares- ac and ventilation system -local humidity temperature indicators , etc- ac and ventilation system -air cooled condensing unit , etc- ac and ventilation system -air handling unit -ahu , etc- ac and ventilation system -strip heaters , etc- ac and ventilation system -pan humidifier , etc- ac and ventilation system -copper refrigerant pipingsuction line , etc- ac and ventilation system - copper refrigerant piping-liquid line , etc- ac and ventilation system -refrigerant gas , etc- ac and ventilation system -gss duct sheet - 24 g - air conditioning system , etc- ac and ventilation system -gss duct sheet - 22 g - air conditioning system , etc- ac and ventilation system -gss duct sheet - 20 g - air conditioning system , etc- ac and ventilation system -gss duct sheet - 18 g - air conditioning system , etc- ac and ventilation system -volume control damper , etc- ac and ventilation system -fire damper , etc- ac and ventilation system -motorised actuator for fire damper , etc- ac and ventilation system -grills diffusers , etc- ac and ventilation system - accoustic insulation , etc- ac and ventilation system -thermal insulation , etc- ac and ventilation system -fine filter , etc- ac and ventilation system - dp switch , etc- ac and ventilation system -fresh air fan assembly , etc- ac and ventilation system - cassette ac unit - 4 tr , etc- ac and ventilation system -cassette ac unit - 3 tr , etc- ac and ventilation system -cassette ac unit - 2 tr , etc- ac and ventilation system -cable laying
Tender For supply of structured cabling in copa lab to enable working with wired network - structured cabling in copa lab to enable working with wired network , access point configuration , exsisting camera installation repeat or reset , electrical job work for installation of online ups , cable laying with pvc and accessories for electric work
Tender For maintenance of electrical installation & fans, repair maintenance of pump sets, sub-station equipments, d.g. sets at ib office 25 akbar road, darbhanga house, new delhi during 2025-26. (sh: supplying and laying of lt cable.)subwork/packages:moei and fans, repair maintenance of pumps sets, sub-station equipments, d.g. sets at ib office 25 akbar road, darbhanga house, new delhi during 2025-26. (sh: supplying and laying of lt cable.)
Tender For corrigendum : supply and installation of electrical fixtures and gadgets in bolpur ib at bolpur under burdwan zone in west bengal. - supply & delivery of 3 phase 415v fixed speed cassette type air-conditioner machine having cooling capacity not less than 14100w, eer 2.7 to 3.2, noise level not more than 56db. this cassette type air conditioning machine should be fitted with scroll compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (make-o-general /mitsubishi electric/mitshubishi heavy industries as per approved by eic/authority)., supply & delivery of 240v split air-conditioner machine having cooling capacity not less than 6875 w, isser 3.8 to 4.39, bee rating not less than 3 star, noise level not more than 46db. this split air conditioning machine should be fitted with rotary compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (o-general /mitsubishi electric /mitshubishi heavy industries as per approved by eic/authority)., installation, testing & commissioning of the above-said split ac outdoor unit on existing iron structure and indoor unit on wall & mending good the damages as per direction of e.i.c., installation, testing & commissioning of the above-said split ac outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of e.i.c., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 3/8"(for discharge) 1.15mm thickness copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 1/2"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & laying of 4core 2.5sq.mm 1.1 kv insulation grade sheathed cu cable with gas line as per direction of eic for making interconnection/communication between indoor to outdoor unit of split type ac m/c.(make- havells/finolex/polycab as approved by e.i.c), supply and laying 5/8(20mm) heavy type pvc pipe for water drainage., supplying, fabrication & fixing of iron stand of m.s. angle size (40 mm x 40mmx6mm) for installation of outdoor unit of 4.0 tr split ac incl. drilling 2 nos holes in each angle and horizontal angle angle 40 mm x40mm x 6 mm in each stand. each stand will be properly fixing by supporting angle (25x25x5mm) and flushnut on peripheral wall as per machine configuration & load with adequate service access as per direction of eic, supplying and fixing 415 v four pole mccb of breaking capacity 25ka/35ka with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing dbs / enclosure and necessary connection (a) 160 amp fp mccb (make legrand/crabtree/siemens/l&t/ abb as approved by e.i.c) [d-8/10], supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection (make legrand/crabtree/siemens/l&t/abb as approved by e.i.c) [d-6/7] (a) 6-32 amp tp mcb, distribution wiring in 1.1 kv single core stranded fr pvc insulated & unsheathed copper wire (brand approved by eic) in 20mm size pvc rigid conduit fr (precision make) incl. necy. fittings as required[e-14] i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ecc [e-14/ 1(a)(iii)], s & f 3phase 9-15a , 415 v dol starter (make-l & t ,cat no. ss94351 or equivalent model of abb/siemens as per dierction of e.i.c) to be fixed on wall with all fixing accessories complete as
Tender For laying 11 kv ug cable on turn key basis and shifting rmus and transformers in coneection with road widening from mangalapuram to vavara amabalam under electrical section mangalapuram
Tender For supply, storage, installation, commissioning and trial run of electro-mechanical equipment at raw water and clear water pumping station under kanchrapara municipality. - for rwps, supply, delivery , storage, installation, testing & commissioning of vertical turbine type centrifugal pump with cashion pipe ,column assembly, discharge head, sole plate, motor stool and all other accessories all complete of 750m /hr discharge at a head of 29 mtr at duty point as per technical specification . maximum allowable speed of pump shall be 1000 rpm., supply, delivery , storage, installation, testing & commissioning of vertical, scim ,tfec, 110 kw (minimum), 415 v 10% , 50hz 05%, speed 1000 rpm (syn) , to vertical pump duty motor to match with pump at sl no- (1) complete with coupling hub and all other accessories as per specification., supply, delivery , storage and installation at site of ms pipes, specials, joints, flanges as per specification and technical offer. (for both individual pump delivery pipe and extended part of common manifold if required) ., supply, delivery and installation and commissioning of valves complete at site with fixture as per specification and technical offer & as follows :-, di butterfly valve for delivery side of pump fitted with electrical actuator suitable for local and control desk operation and display system for the individual pump delivery pipe line. (350 mm minimum))(pn 16 type), di non-return valve for individual pump delivery pipe line. (350 mm. minimum))(pn 16 type), supply, delivery at site and storage of m.s. dismantling joint assembly for the individual pump delivery pipe line as per specification (350 mm minimum)., supply, delivery ,storage and installation at site of pressure gauges complete with fittings and fixture as per specification, pressure gauge for delivery side (0 10 kg / cm2), supply, delivery ,storage and installation at site of pressure transmitter complete with fitting and fixture as per specification as follows:-, pressure transmitter for delivery side ( 0 10 kg / cm2 ), supply, delivery at site and installation of m.s. structural materials for cable tray / rack, panel installation supports, pipes & valves supports, fabricated stairs & all other fabrication work., lt panel, modification / retrofitting/expansion/addition of the existing pmcc with supply , delivery & installation of a new additional motor starter feeder at rwph in order to accomodate the extra pump-motor feeder of requisite rating not less than 110 kw .the modification/addition should match/synchonise the existing panel and should ensure smooth operation of the complete panel as a single entity and should be fit to install at the existing pump house., retrofitting of existing control desk at site with supply,wiring, installation of additional items like temparature scanner , multifunction meter , microprocessor based position indicator, digital pressure indicator,tnc switch, push button switch, indication lamps etc .as required to complete for the new pump motor set., supply ,delivery, laying, installation of power cable of adequate size from motor feeder to motor .(min. 2 run x 3core , 185 sq mm xlpe armoured al. for each feeder), supply ,delivery, laying, installation of power cable of adequate size and length from pmcc to motor space heater . (min. 3 core 2.5sq mm. armoured cu for each motor), supply ,delivery, laying, installation of power cable of adequate size and length from pmcc to valve actuator etc. elsewhere required. (min . 4 core 2.5 sq mm. armoured cu), making end termination of all the power cables as stated in sl no 11,12,13 with all necessary equipments like termination kits(dry type), lugs , glands etc , installed for the modification job., supply ,delivery, laying, installation of control cables of different size as required for the purpose and length for completing the different control connections between control desk, motor feeders , lpbs, pmcc etc.to the satisfaction o
Tender For renovation upgradation of electrical distribution system of gauhati university and laying underground ug cable to rcc-1 and rcc-2 boys hostel including necessary civil works