Web Analytics Made Easy - StatCounter

Optical Fibre Cable Repair Tenders

Get complete information related to latest Optical Fibre Cable Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Optical Fibre Cable Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Optical Fibre Cable Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45492829 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For supply of vrf or vrv air cooled outdoor units suitable for cooling or heating having 100 percent hermetically sealed inverter type twin rotary or scroll compressor capacity of machines 14 hp to 22 hp , following minimum capacity 4 way vrv or vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter,3 point 2 tr , following minimum capacity 4 way vrv or vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter,4 tr , vaccumiazation and nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for vrv or vrf system, thickness 1 point 2 mm , 9 point 5 mm dia od soft drawn with tube thickness 1 point 2 mm , 12point 7 mm dia od soft drawn with tube thickness 1point 2 mm , 15 point 86 mm dia od soft drawn with tube thickness 1point 2 mm , 19 mm dia od hard drawn with tube thickness 1 point 2 mm , 22 point 2 mm dia od hard drawn with tube thickness 1 point 2 mm , 25 point 4 mm dia od hard drawn with tube thickness 1 point 2 mm , 28 point 58 mm dia od hard drawn with tube thickness 1 point 2 mm , 34 point 9 mm dia od hard drawn with tube thickness 1 point 62 mm , 41 point 27 mm dia od hard drawn with tube thickness 1 point 62 mm , s i t c of y joints kit refrnet , drain piping rigid pvc piping complete with fittings supports as per specifications and insulated with 6mm thick closed cell elastometric nitrile rubber insulation 25mm dia and , 32 mm dia , 40mm dia , control and transmission wiring , testing and commissioning of vrf or vrv systems including topping of r410a gas as per site requirements , supply and installation of u or v protection of used copper pipe at outer site for odu connection site , 6way load bank double door enclosure confirming to is 8623 iec 60439 g frame panel boards , supplying and fixing of following sizes of medium class pvc conduit along with accessories 25mm , frlsh or hffr pvc insulated copper conductor single core cable in the existing surface or recessed steel or pvc conduit as required 3 x 1 point 5 sq mm , suitable size gi box with modular plate and cover in front on surface or in recess , one number xlpe insulated and pvc sheathed copper conductor armoured power cable of 1 point 1 kv grade 4 x 16 sqmm , 16 a rating 240 by 415 v 10 ka c curve miniature circuit breaker suitable for nductive load of following poles in the existing mcb db complete with connections single pole , single pole and neutral sheet steel mcb distribution board 240 v on surface by recess complete 12 way double door , supplying and fixing 25 a rating single pole and neutral , following size of perforated painted with powder coating m s cable trays 150 mm width x 50 mm depth x 1point 6 mm thickness , earthing with g i earth pipe 4 point 5 metre long 40 mm dia including accessories , providing and laying earth connection from earth electrode , providing and fixing 6 swg dia g i wire on surface or in recess for loop earthing , amc as per section c , installation of cassette ac 2 ton 5 star , copper pipe , 4 core copper wire , drain pipe with insulation , odu stand , cable tray , hanging rod , faster nut , wrapping tape , 3 core copper wire

State Government

CTN :45231232 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For corrigendum : supply and execution items for reliability improvement of signalling inst. section of sr. dste/1/lko of lucknow div. nr. - excavating and refilling of trench to the level of ground with rammed earth asper drg. no.(nr/s&t/con/1.1/97a) so as not to form a drain 0.3 mtrs wide & 1mtr deep on both side of the station along side the track. it shall confirm to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes., excavating and refilling of trench 0.3 mtrs wide & 0.8 mtr deep on pitced/stone/bricks paved surface, road/crossing/platform etc. and restoration of surafce to original condition., laying of signalling/telecom/power cables of different sizes as per attached guidelines (drg. no.(nr/s&t/con/1.1/97a) or latest on signalling cable laying and as per cable route plan approved by railways through trenches, rcc pipe, dwc pipe, gi pipe etc and meggering of cable before and after its laying of all type of outdoor cables. contractor have to transport cable from any store of lko division to site carefully. meggering to be done for each drum separately. meggering sheets to be supplied and filled up by contractor and submitted to railways, as per instructions by consignee., supply and laying of 2nd class bricks in the trench and laying as per drg. no. (nr/s&t/con./1.1/97a) or latest and as per instruction of the site engineer., boring and trenchless cabling along with supply and insertion of hdpe/dwc self lubricated pipes as per rdso spec no. rdso/spn/204/2011 ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by engineer incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. inspection-consignee for supply of dwc/hdpe pipe. the following required coupling arrangement should also be supplied: 1. suitable snap fit couplers withrubber o ring, 2. spacers, 3. tees. 4. bend. 5. end cap(1 no. =6mtr ,straigh tpipe). (a) the cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (b) the rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. nothing extra shall be admissible on any account than the rate quoted above. (c) the pipeis to be laid underrailway track/road /culvert. all necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizontal and vertical direction. (d) the rate shall be inclusive of direction and protection of underground utilities encountered during boring. (e) the payment for boring shall be made only when dwc/hdpe pipe are laid in the bore., concreting unschduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. it also includes the excavation of earth as required at site and as per instruction of site incharge. the volume in cubic metres shall include the volume occupied by any ci foundation, trestle, ms angle or flat or gi pipe required to be embedded in the casting. cement coarse sand and aggregate 25mm are to be supplied by the contractor., earth work for excavation and refilling around location boxes and signals etc. where necessary including 50m lead and 1.5m lift. the lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. the earth work should be well rammed including breaking of clods, levelling and dressing etc. as per instruction of engineer at site., brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary) mixture of 1:4 ratio. all material is to be supplied by th

Central Government/Public Sector

CTN :45463412 Due date: 22 Jun, 202622 Jun, 2026 10.44 Lacs
Tender For dismantling of existing steel tower and diversion of 33kv feeder no. 12 and feeder no. 13 by laying of 33kv grade cable and for providing overhead line for 33kv 12 and 13 no. feeder near silo 5 and 6 under power supply of gevra project

corporations/Associations/Others

CTN :45175679 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For corrigendum : supply of outdoor active led display 2200042999 , content management software 2200043010 , server application workstation 2200043011 , ups 3 kva 1600055767 , smf battery 12v 65ah 1600033593 , supplying and laying of 3 core x 2.5sqmm armoured frls power cable , supplying and laying of cat6 armoured cable for network connectivity , installation and commissioning , onsite camc charges for 3rd year , onsite camc charges for 4th year , onsite camc charges for 5th year

corporations/Associations/Others

CTN :45251649 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For corrigendum : providing of custom bid for services - power cable laying and termination at downhill 11c for provision of lt supply throughout the downhill 11c conveyors of ocsl plant kirandul

CTN :44823236 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For bid to ras supply of ncn connectivity d d - casing caping , conduit pipe and flexible , 9u cabinet include all accessories , e2k to lc patch cords , jack panel 24 port , punching and cable termination , liu unit lc lc , laying of fiber cables 6f , lc to lc patch cords , sfp 1.25g 20km smf duplex , laying of cat 6 cable , splicing with pigtails , power meter , lan tester , crimping tool , jetty cable odc connector , io box , 4u rack with accessories

CTN :45197979 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For corrigendum : supply of ip cameras four mp , ptz camara , nvr sixteen ch , utp cat six cable , fiber cable , power cable , fiber joint box , power extension board , media convertor , patch cord , managed switch twentyfour port gigabit , eight port poe switch , poe injector , connector , hdd four tb , fhd monitor fifty inch , invertor with two battery bank , fiber cable laying and connection , network rack , installation charges for cctv

CTN :45420021 Due date: 10 Jun, 202610 Jun, 2026 2.33 Lacs
Tender For supplying and laying of lt aluminium armoured cable for supply power from newly installed transformer to electric meter panel in ispw office building at gangtok, sikkim.subwork/packages:supplying and laying lt aluminium armoured cable.

CTN :45427278 Due date: 13 Jun, 202613 Jun, 2026 NA
Tender For design, supply, laying, testing and commissioning including dismantling, upgradation of an existing lt power cable network including allied works & supply, installation, testing and commissioning of distribution boxes with locking arrangements, at arun jaitley stadium, new delhi

State Government

CTN :45441299 Due date: 19 Jun, 202619 Jun, 2026 13.91 Lacs
Tender For 11kv cable laying work including supply of jointing kit metering switchgear for effecting bulk power supply i.r.o canara bank at aa-cbd newtown aa - ii under newtown division wbsedcl - 11kv cable laying work including supply of jointing kit & installation of metering switchgear for effecting bulk power supply i.r.o canara bank at aa-cbd ,newtown aa - ii under newtown division, wbsedcl
 Loading, Please wait...

Connect us via What's Up