Tender For supply of reaction frame of 150 ton capacity for hydraulic jack testing with load cell & digital display reaction frame capacity 150 ton safe over load 200 ton height - 1000 mm, hyd jack testing width 500 mm hyd jack testing. [ warranty period: 30 months after the date of delivery ] ]
Tender For e tender for procurement of kits, chemicals and reagents for two years from the date of award of contract (aoc) and its extension, if required - "rh +k phenotyping glass bead cassettestechnical specification:1.cassttes should contain 6 columns filled with glass bead as filtration media 2.1st column to 5th column should be prefilled with monoclonal antisera such as anti c, anti e, anti c, anti e, anti k respectively and 6th column is 'control' column. 3.peg should be present in the columns as enhancer to increase uptake of antibody 4. assay time should be as per manufacturer's guideline / brochure 5. mixed field reaction /double cell population should be detected " , "ahg poly specific glass bead cassettes technical specification:1. cassettes should contain 6 columns filled with glass beads filtration media 2. all column should prefilled with ahg reagent (anti igg , anti c3d)3. assay time should be as per manufacturer's guideline / brochure 4. mixed filled reaction /double cell population should be detected" , "blood grouping (forward & reverse grouping) glass bead cassettes technical specification: 1. cassettes should contain 6 columns filled with glass bead as filtration media 2. 1st to 3rd colums should be prefilled with monoclonal antisera with a serial of anti a, anti b, anti d respectively and rest 3 colums contain 1 for 'control' and 2 colums for reverse grouping with variable serial.3. peg should be present in the columns as enhancer to increase uptake of antibody 4. centrifugation time should be as per manufacturer's guideline5. mixed field reaction /double cell population should be detected" , "monoclonal antisera for extended rh+k phenotypinganti c technical specification:anti c sera should be monoclonal anti c sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti ctechnical specification:anti c sera should be monoclonalanti c sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti e technical specification:anti e sera should be monoclonal anti e sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti etechnical specification:anti e sera should be monoclonal anti e sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti k (kell)technical specification:anti k sera should be monoclonal anti k sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "panel for antibody 3 cell screening applicable to conventional test tube method and glass bead cassettes technical specification: 1. cell panel should be 2%-5% of rbc suspended in saline 2. cell panel should be compatible with both conventional test tube method and glass bead cassettes of column agglutination technology for doing antibody screening test3. cell panel should contain rbc with the antigens of extended rh, kell, duffy, kidd, lewis, mns etc blood group system4. dose depended antigens (like mns, duffy etc) should be present in homozygous as per criteria of antibody screening test 5. cell panel should be compatible for enzyme treatment 6. pack size should be as per manufacturer's guideline / brochure " , "panel for antibody 3 cell screening applicable to gel card technical specification:1.cell panel should be 0.8%-1% of rbc suspended in low ionic strength saline2. cell panel should be compatible with gel card of column agglutination technology for doing antibody screening test3. cell panel should contain rbc with the antigens of extended rh, kell, duffy, kidd, lewis, mns etc blood group system4.dose depende
Tender For e tender for procurement of kits, chemicals and reagents for two years from the date of award of contract (aoc) and its extension, if required - "rh +k phenotyping gel card technical specification:1. cassettes should contain 6 columns filled with sephadex gel as filtration media 2. 1st column to 5th column should be prefilled with monoclonal antisera such as anti c, anti c, anti e, anti e, anti k respectively and 6th column is 'control' column. 3. assay time should be as per manufacturer's guideline / brochure 4. mixed field reaction /double cell population should be detected", "diluents for rh +k phenotyping gel card"
Tender For supply of molecular flow module for use with comsol multiphysics , electric discharge module for use with comsol multiphysics , corrosion module for use with comsol multiphysics , subscription for technical support and upgradation of existing comsol multiphysics core or base module , subscription for technical support and upgradation of existing rf module of comsol multiphysics , subscription for technical support and upgradation of existing ac or dc module of comsol multiphysics , subscription for technical support and upgradation of existing design module of comsol multiphysics , subscription for technical support and upgradation of existing heat transfer module of comsol multiphysics , subscription for technical support and upgradation of existing chemical reaction engineering module of comsol multiphysics , subscription for technical support and upgradation of existing composite materials module of comsol multiphysics , subscription for technical support and upgradation of existing electrochemistry module of comsol multiphysics , subscription for technical support and upgradation of existing material library module of comsol multiphysics , subscription for technical support and upgradation of existing particle tracing module of comsol multiphysics , subscription for technical support and upgradation of existing plasma module of comsol multiphysics , subscription for technical support and upgradation of existing semiconductor module of comsol multiphysics , subscription for technical support and upgradation of existing structural mechanics module of comsol multiphysics , subscription for technical support and upgradation of existing acoustics module of comsol multiphysics , subscription for technical support and upgradation of existing electrodeposition module of comsol multiphysics , subscription for technical support and upgradation of existing battery design module of comsol multiphysics , subscription for technical support and upgradation of existing fuel cell and electrolyzer module of comsol multiphysics , subscription for technical support and upgradation of existing mems module of comsol multiphysics , subscription for technical support and upgradation of existing nonlinear structural materials module of comsol multiphysics , subscription for technical support and upgradation of existing ray optics module of comsol multiphysics , subscription for technical support and upgradation of existing wave optics module of comsol multiphysics , subscription for technical support and upgradation of existing cfd module of comsol multiphysics , subscription for technical support and upgradation of existing geomechanics module of comsol multiphysics , subscription for technical support and upgradation of existing subsurface flow module of comsol multiphysics
Tender For purchase of chemicals - purchase of chemicals, diluent for dna extractionsize 500mla diluent used in dna extraction is typically te buffer (10 mm tris-hcl, 1 mm edta, ph ~8.0) or nuclease-free water, used to dissolve and dilute extracted dna. tris maintains a stable ph, while edta chelates divalent cations (e.g., mg ), thereby inhibiting dnase activity and protecting dna from degradation. the diluent must be sterile and free of nucleases to ensure the integrity of dna for downstream applications such as pcr, sequencing, and cloning., luria bertani mediumsize 500gluria bertani medium is a nutrient-rich growth medium commonly used for culturing bacteria such as escherichia coli and agrobacterium tumefaciens. it contains tryptone (10 g/l), yeast extract (5 g/l), and sodium chloride (10 g/l), which provide essential nutrients, vitamins, and osmotic balance for bacterial growth. lb medium supports rapid cell growth and is widely used in molecular biology for cloning, plasmid propagation, and transformation experiments. for solid media, agar (15g/l) is added., chloroform (high analytical reagent grade) size 2.5lchloroform (high analytical reagent grade) is a high-purity organic solvent used in dna extraction, particularly in phenol chloroform methods, to separate proteins and other contaminants from nucleic acids. it enhances phase separation by forming a distinct organic layer, allowing dna to remain in the aqueous phase. due to its toxicity and volatility, it must be handled under a fume hood with proper safety precautions., depcsize 25mldepc is a chemical used to inactivate rnases in water and laboratory solutions, making them suitable for rna work. it modifies histidine residues in proteins, thereby deactivating rnase enzymes that can degrade rna. depc-treated solutions are typically incubated and then autoclaved to remove residual depc, ensuring they are safe for use in downstream applications such as rna extraction and cdna synthesis., tb green master mixsize 200rnxtb green master mix is a ready-to-use reagent used in real-time pcr (qpcr) for dna amplification and detection. it contains tb green dye (a double-stranded dna-binding fluorescent dye), dna polymerase, dntps, mg , and reaction buffer. the dye binds to amplified double-stranded dna and emits fluorescence, allowing real-time monitoring of pcr amplification. it is commonly used for gene expression analysis and quantification of dna., dna loading dyesize 10 inchdna loading dye is a solution added to dna samples before agarose gel electrophoresis. it contains tracking dyes (such as bromophenol blue and xylene cyanol) that allow monitoring of dna migration during the run, and a dense agent (such as glycerol or sucrose) that helps the sample sink into the wells. it may also include edta to protect dna from nuclease degradation., metaloopa metal loop is a reusable laboratory tool made of platinum or nichrome wire, used for transferring and inoculating microorganisms onto culture media. it is sterilized by heating in a flame until red hot before and after use to prevent contamination. it is commonly used in microbiology for streaking plates and handling bacterial cultures.
Tender For bid to ras corrigendum : supply of kit for estimation of creatinine meril 4x604x15 ml , kit for estimation of albumin meril 6x50 ml , kit for estimation of sgpt meril4x604x15 ml , amylase kit compatible for meril autoquant 400 analyser only6x20 ml , alkaline phosphatekit compatible for meril autoquant 400 analyser only 6x20 ml , bilirubin total kit compatible for meril autoquant 400 analyser only 4x45 ml4x15 ml , bilirubin direct kit compatible for meril autoquant 400 analyser only 4x454x15 ml , calcium kit compatible for meril autoquant 400 analyser only 4x20 ml , cratinine kinase mb kit compatible for meril autoquant 400 analyser only ckmb4x604x15 ml , cholesterol kit compatible for meril autoquant 400 analyser only 6x70 ml , lactatedehydrogenase ldh kit compatible for meril autoquant 400 analyser only 2x60 ml2x15 ml , microprotein kit compatible for meril autoquant 400 analyser only 6x20 ml , urea kit compatible for meril autoquant 400 analyser only 4x604x15 ml , detergent alkaline compatible for meril autoquant 400 analyser only 1000 ml , biopath kit compatible for meril autoquant 400 analyser only 1x5 ml , bio cal kit compatible for meril autoquant 400 analyser only 4x3 ml , hdl cholesterol direct compatible for fully auto biochemistry analyser autoqua , ggutamyl transferase ggt kit compatible for fully auto biochemistry analyser , glucose kit compatible for fully auto biochemistry analyser autoquant 400 6x70 ml , total protein kit compatible for fully auto biochemistry analyser autoquant 400 6x20 ml , triglyceride kit compatible for fully auto biochemistry analyser autoquant 400 6x70 ml , uric acid kit compatible for fully auto biochemistry analyser autoquant 400 4x50 ml , bionorm kit compatible for fully auto biochemistry analyser autoquant 400 1x 5 ml , lipase tset kit for meril auto quant 400 , kit for estimation of sgot meril4x604x15 ml , petri dish disposable 150 mm , erban control for coagulation , erbap control for coagulation , biochemical test kit for diffrentiation of enterobacteriacea 20 test , optochin dcisc 50 disc , bacitracin disc 50 disc , microscope lens cleaner spray 50 ml , ec cartidge s for ec 90 electrolyte analyzer , glass made cover of microscopic rectangular 22 x 30 mm usp no1 glass , membrane high tds for di water plant , ro booster pump e chan 100 gdp original for two membrane , adeptorsmps 2436v , rasin for zero tds , tds meter , cartage pp spun 0dot5 micron for distilled water plant , thread dust filter for distilled water plant , l j medium slantspack of 10 , sample cup 2 ml pack of 500 , pa colifornm kit for water culture , calibrator for h 360 , control for h 360 , printer cartridge for pantum p2210with biochemistry analyzer , abst disccombi disc gn 2 , abst disc combi disc gp 2 , abst disc combi disc gp 1 , abst disc combi disc gn 2 , wash solution auto quant cleanzer 10x100 ml , hepatitis a iggigm rapid kit pack of 25 test , hepatitis e iggigm rapid kit pack of 25 test , stopwatch timer , reaction cuvette for auto quant 400 meril set of 80 cuvettes , liss coombs card card by column agglutination technology cat compatible with matrix get , red cell diluent for preparation on red cell suspension for cat bott of 250ml compatible with matrix , pesiatric blood bags , ckmb for ichroma2 kit of 25 tests , rectanguar meuseum jar 8x8x6 //bid details 2 / 50