Get complete information related to latest Orp Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Orp Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Orp Meter Tenders.
Tender For supply of 50005448 cal of velocity transmitter , 50005449 cal of rh sensor , 50005460 cal of diff pres transmitter , 50005370 calibration of temp rh sensor , 50005477 cal of ph sen with meter , 50005478 cal of orp sen with meter , 50005458 cal of pressure gauge , 50005470 cal of dig water flow meter iwflmtr013 , 50005471 cal of dig water flow meter , 50005473 cal of water flow meter iwflmtr016 , 50005474 cal of anlog water flow meter iwflmtr017 , 50005475 cal of anlog water flow meter iwflmtr018 , 50005476 cal of dig water flow meter iwflmtr019 , 50006503 cal of analog water flow meter , 50006504 cal of analog water flow meter 100 to 1000l , 50006502 calibration of orpmeter with sensor
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh
Tender For armo of various e&m services for various non-residential bldg. and residential qtrs. at nasc complex, pusa, new delhi. (sh: replacement of existing damaged/ defective ro membrane and supply, installation, testing and commissioning of orpmeter with dump valve in existing eureka forbes make 3000 lph ro plant )
Tender For armo of various electrical and mechanical services for various non-residential bldg. and residential qtrs. at nasc complex, pusa, new delhi. (sh: replacement of existing damaged/defective ro membrane and supply, installation, testing and commissioning of orpmeter with dump valve in existing eureka forbes make 3000 lph ro plant)