Get complete information related to latest Outgoing Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Outgoing Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Outgoing Cable Tenders.
Tender For corrigendum : supply of lugs ferrules c c - ta sl no 4 1 1 solderless insulated pin type copper lugs as per ta sl nos 4 1 1 1 to 4 1 1 12 , ta sl no 4 1 2 solderless insulated bootlace type copper lugs as per ta sl nos 4 1 2 1 to 4 1 2 7 , ta sl no 4 1 3 insulated ring type tongue terminal end copper lugs as per ta sl nos 4 1 3 1 to 4 1 3 6 , ta sl no 4 1 4 non insulated ring type tongue terminal end as per ta sl nos 4 1 4 1 to 4 1 4 11 , ta sl no 4 1 5 non insulated tubular terminal end as per ta sl nos 4 1 5 1 to 4 1 5 4 , ta sl no 4 1 6 snap on terminals as per ta sl nos 4 1 6 1 , ta sl no 4 2 halogen free flame retardant self locking cable markers ferrules as per ta sl nos 4 2 1 to 4 2 1 10 , ta sl no 4 2 2 self locking cable markers as per ta sl nos 4 2 2 1 to 4 2 2 36 , ta sl no 4 2 3 self locking cable markers as per ta sl nos 4 2 3 1 to 4 2 3 36 , ta sl no 4 2 4 self locking cable markers as per ta sl nos 4 2 4 1 to 4 2 4 18 , ta sl no 4 2 5 self locking cable markers as per ta sl nos 4 2 5 1 to 4 2 5 36 , ta sl no 4 2 6 self locking cable markers as per ta sl nos 4 2 6 1 to 4 2 6 11 , ta sl no 4 2 7 self locking cable markers as per ta sl nos 4 2 7 1 to 4 2 7 11 , ta sl no 4 2 8 self locking cable markers as per ta sl nos 4 2 8 1 to 4 2 8 11 , ta sl no 4 2 9 self locking cable markers as per ta sl nos 4 2 9 1 to 4 2 9 9 , ta sl no 4 2 10 self locking cable markers as per ta sl nos 4 2 10 1 to 4 2 10 16 , ta sl no 4 2 11 self locking cable markers as per ta sl nos 4 2 11 1 to 4 2 11 16 , ta sl no 4 2 12 self locking cable markers as per ta sl nos 4 2 12 1 to 4 2 12 16 , ta sl no 4 3 flame retardant non toxic heat shrinkable sleeves 0 5 sq mm as per ta sl nos 4 3 1 to 4 3 1 3 , ta sl no 4 3 2 flame retardant non toxic heat shrinkable sleeves 0 75 sq mm as per ta sl nos 4 3 2 1 to 4 3 2 3 , ta sl no 4 3 3 flame retardant non toxic heat shrinkable sleeves 1 5 sq mm as per ta sl nos 4 3 3 1 to 4 3 3 3 , ta sl no 4 3 4 flame retardant non toxic heat shrinkable sleeves 2 5 sq mm as ) /bid number: gem/2025/b/6921233 * /dated: 22-11-2025 & & / bid document1 / 35 & & ' ' /item categoryper ta sl nos 4 3 4 1 to 4 3 4 3 , ta sl no 4 3 5 flame retardant non toxic heat shrinkable sleeves 4 sq mm as per ta sl nos 4 3 5 1 to 4 3 5 3 , ta sl no 4 3 6 flame retardant non toxic heat shrinkable sleeves 6 sq mm as per ta sl nos 4 3 6 1 to 4 3 6 3 , ta sl no 4 3 7 flame retardant non toxic heat shrinkable sleeves 10 sq mm as per ta sl nos 4 3 7 1 to 4 3 7 3 , ta sl no 4 3 8 flame retardant non toxic heat shrinkable sleeves 16 sq mm as per ta sl nos 4 3 8 1 to 4 3 8 3 , ta sl no 4 3 9 flame retardant non toxic heat shrinkable sleeves 25 sq mm as per ta sl nos 4 3 9 1 to 4 3 9 3 , ta sl no 4 3 10 flame retardant non toxic heat shrinkable sleeves 50 sq mm as per ta sl nos 4 3 10 1 to 4 3 10 3 , ta sl no 4 3 11 flame retardant non toxic heat shrinkable sleeves 70 sq mm as per ta sl nos 4 3 11 1 to 4 3 11 3 , ta sl no 4 3 12 flame retardant non toxic heat shrinkable sleeves 95 sq mm as per ta sl nos 4 3 12 1 to 4 3 12 3 , ta sl no 4 4 flame retardant non toxic heat shrinkable pvc sleeves blue as per ta sl nos 4 4 1 to 4 4 6 , ta sl no 4 5 stainless steel flexible conduit as per ta sl nos 4 5 1 to 4 5 3 , ta sl no 4 6 pvc flexible conduit as per ta sl nos 4 6 1 to 4 6 3 , ta sl no 4 7 copper tube heavy duty in line connectors as per ta sl no 4 7 1 , ta sl no 4 8 pg type cable entry glands as per ta sl nos 4 8 1 to 4 8 6 , ta sl no 4 9 pg type cable entry glands as per ta sl nos 4 9 1 to 4 9 6 , ta sl no 4 10 316 stainless steel cable ties coated with flame retardant as per ta sl no 4 10 1 , ta sl no 4 10 316 stainless steel clamp as per ta sl no 4 10 2 , ta sl no 4 10 316 stainless steel cable ties coated with flame retardant as per ta sl no 4 10 3 , ta sl no 4 10 316 stainless steel clamp as per ta sl no 4 10 4 , ta sl no 4 10 hand tool for adjusting tension forming lock cutting as per ta sl no 4 10 5 , ta sl no 4 11 non releasab
Tender For corrigendum : tggenco-ktps vii stage/paloncha - supply of various consumables - dc 2-26, electrical-mechanical, multi-use lubricant danmet chemicals, 415 ml tin , power distribution block, 1x4 way, incoming cable size: 35 sq mm, outgoingcable size: 10 10sq.mm mm, model: dbk 1x4, make: elmex, 10 numbers of each color (red, blue, yellow), , cutting wheel ag4, diameter: 100 x 16 mm, thickness: 1.2 mm, model: a60nbf, make: bosch, , ag4 buffering wheel, type: flap, model: non-wired & for metal polishing, dimensions: 100 x 4 x 16 mm, make: bosch, , grinding wheel ag4, diameter: 100 x 16 mm, thickness: 4 mm, make: bosch, , bimetallic ring type terminal lugs, size: 25 sq mm, catalog no: caf-25-10, make: dowells, , bimetallic ring type terminal lugs, size: 35 sq mm, catalog no: caf-35-10, make: dowells, , bimetallic ring type terminal lugs, size: 50 sq mm, catalog no: caf-50-13, make: dowells, , bimetallic ring type terminal lugs, size: 70 sq mm, catalog no: caf-70-13, make: dowells, , bimetallic ring-type terminal lugs, size: 95 sq mm, catalog no.: caf-95-13, make: dowells, , bimetallic ring-type terminal lugs, size: 150 sq mm, catalog no.: caf-150-13, make: dowells,
Tender For tender for supply of deisgn engineering and supply of electrical instrumentation and civil works : : - design and engineering of imcc panel 2 nos and vfds , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoingcables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , supply of imcc panels , vfd panels , supply of apfc panels , hvac system , supply of mldb lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material etc , supply of field instruments and necessary piping materials as required , supply of plc , supply lt cables and other related accessories for electrical , termination material and other instrumentation cables as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables ( cable terminations wherever required along with necessary accessories is in the scope of the contractor) for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , substructure excavation , foundation works (footings , columns up to plinth level) , dpc (damp proof course) , and backfilling. , superstructure columns , beams , slabs , brickwork/masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoingcables
Tender For corrigendum : manufacture, fabrication, supply,erection, testing and commissioning with 1x8 mva pr.tr,stn transformer, associated equipments, accessories, control panels, control room and electrical works at o.krishnapuram in trichy metro under tkc thro e tener - electrical material supply, power transformer 33/11kv, 8mva power transformer with oltc, breaker along with ct for outdoor ss 33 kv (gc) vcb (out door) 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (600-300/1-1a) with structure and complete accessories with breaker platform., 11kv (lv) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulatedwith permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (1200-600/1-1a) with structure and complete accessories with breaker platform., 11kv (feeder) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (400-200/1-1a) with structure and complete accessories with breaker platform., potential transformer 33kv potential transformer with tc (single phase unit), 11kv potential transformer with tc (three phase unit), panels ac panel for 33kv ss, 110 v dc annunciation panel type b, 110v dc indoor c&r panel for gc breaker, 110v dc indoor c&r panel for lv breaker, 110 v dc indoor c&r panel for twin feeder, control cables, junction box and accessories 14c x 2.5 sq.mm copper cable armoured, 8c x 4 sq.mm copper cable armoured, 4c x 4 sq.mm copper cable armoured, 4c x 2.5 sq.mm copper cable armoured, 2c x 2.5 sq.mm copper cable armoured, isi mark 19 / 22 mm cable gland as directed by the field engineer., isi mark 25 mm cable gland as directed by the field engineer., isi mark cable 28 mm gland as directed by the field engineer., lugs, ferrules, sleeves, cable tie, insulation tape and other accessories for providing cable core end termination, supply of gi chequerred plate 6mm thickness, junction box supply of ct/pt junction box made out of 14swg (2mm) m.s.sheet wherever required as directed by the field engineer. the box shall be vermin proof shall have sturdy hinges, provision for mounting terminal blocks and locking arrangements including cost of all materials. 400w x 300h x 150d, supply of ac junction box of size 535x310x127mm of 18swg ms sheet including hrc fuse unit-18 nos. should be fitted with base, consumables etc. (the box shall be vermin proof, shall have sturdy hinges and locking arrangements), supply of mounting channel suitable for cbtm 5 terminal block in panel /box as required and as directed by the field engineer., supply of disconnected type terminal block suitable for ct circuits in panels/ box as required & as directed by the field engineer, supply of isi mark bakelite hrc fuse holder with fuse of 2/5/10/16 amps reputed make in panels/ boxes for ac/dc/pt circuits wherever required as directed by the field engineer. 16 amps - fuse holder with hrc fuse, 63amps - fuse holder with hrc fuse, bus & bus materials zebra acsr conductor, 2.0" / 50 mm aluminium bus bar (thickness:5 mm), 22/33 kv pt insulators, 11kv pt insulator, 11kv, 120kn disc insulators (antifog), strung bus eye bolt of 18 - 20 mm dia gi rod of required length suitable for 33kv, 22kv and 11kv strung bus including cost of gi rod and 2nos gi nuts & washer as directed by the field engineer., clamps and connectors tension fitting clamp 4 bolted for zebra, t clamp for 2" bus to single zebra, t clamp for zebra to zebra, switchend clamp for single zebra, switchend clamp for 2" busbar, reducer clamp for 2" bus to zebra, pg clamp for zebra, free end clamp for 2"busbar, corana bell for 50mm bus bar, switch end clamp for mink, seating block for 2" bus bar(for g
Tender For e-tender for the work of repairing of transformer distribution box, reinsulating of lt incoming & outgoingcables with heat shrinkable sleeves under tuljapur division (as per msedcl specification).