Get complete information related to latest Output Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Output Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Output Meter Tenders.
Tender For corrigendum : supply of equipment for mechanical engineering department - supply of equipment for mechanical engineering department, lathe machine :specification :bed: 2v & 2 flat, induction hardened and ground minimum bed length: 1375 mm bed width: 240 mm capacity: height of centre: 165 mm swing over bed: 320 mm swing over gap: 510 mm swing over cross slide: 180 mm distance between centres: 650 mm slides: cross slide travel: 200 mm compound slide travel: 115 mm spindle: spindle bore: 40 mm spindle nose: thread type, 62 mm spindle taper: mt-3 tail stock: quill diameter: 38.1 mm taper: mt-3 travel: 120 mm speed: no. of speeds: minimum 8 range: (40 800 )rpm threading: metric: (1 6 )mm (min 13 steps) english: (2 24 )tpi (min 19 steps) lead screw: (1 4) tpi electrical: motor: 1.5 hp, 230v/415v, 50 hz drive: v-belt structure: bed: close-grained cast iron (fg 260) gears: hardened steel base: rigid cast iron stand , open cup apparatus :specification :standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 6 c per minute (as per standard) temperature range: -6 to 400 c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valvebody: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hz safety: overheat protection heat insulation , closed cup apparatus :specification :standard compliance: astm d93 / is 1448 (part 21) test cup:brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustable ignition: pilot flame with automatic shutter mechanism temperature measurement: thermometer or digital sensor(ip-28c or astm) display: digital temperature display power supply: 230v ac, 50 hz safety:over-temperature cut-off flame safety control , tail stock assembly :specification :medium-duty tailstock assembly for dismantling & assembly quill stroke: minimum 75 mm taper: mt-3 (preferred standard) feed: hand wheel operated features: set-over screws for taper turning spindle locking arrangement body: cast iron (fg 260) spindle: hardened steel, slip gauge :specification :set size: m87 (87 pieces) or equivalent range: 1.001 mm to 100 mm step sizes: 0.001 mm 0.005 mm 0.01 mm material: high-grade alloy steel / tungsten carbide (preferred) hardness: hrc 63 65 accuracy: grade: grade 1 or grade 2 flatne flatness / parallelism: 0.5 m stored in protective wooden boxes to prevent wear; calibration grades include charts for exact sizes , dc motor:specification :type: dc shunt motor (dismantling model) power: minimum 0.5 hp voltage: 220 v dc speed: 1500 rpm poles: 4 pole construction: laminated stator salient poles accessible armature features: cut section / open type suitable for dismantling and reassembly, hydraulic cylinder :specification :bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steel calibration grades include charts for exact sizes supply: mounted on training base suitable for dismantling and inspection , hydraulic operated directional control valves (dcv):specification :type: manual spool type dc valve configuration: 4/2 way size: ng06 (cetop 3) rated pressure: 210 bar flow capacity: 20 40 lpm body: hardened steel / cast steel spool: ground and hardened ports: clearly marked (p, a, b, t) supply: mounted on training plate suitable for dismantling and study , bearing with shaft assembly :specification :bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steelsupply:mounted on training base suitable for dismantling and inspection , coupling unit using
Tender For purchase of lab equipments for gptc tvt chemistry department - purchase, digital electronic balance /analytical balance load capacity: minimum 500 g readability: 0.01 g linearity: 0.02g display: lcd/led tare function: required top pan type power supply: 220 240 v ac, 50 hz, digital tds meter measuring range: 0 9990 ppm resolution: 1 ppm display: lcd automatic temperature compensation (atc): required waterproof: minimum ip67 protectionpower source: battery operated (button cell/aaa battery), digital ph meter benchtop model ph type microprocessor/microcontrolle r ph range: 0 14 resolution: 0.01 ph accuracy: 0.05 ph or better combined ph electrode with temperature sensor two or three-point calibration facility temperature compensation type automatic display: lcd power supply: 220 240 v ac, 50 hz warranty minimum 1 year , laboratory heating mantle (knitted glass yarn) capacity: 500ml temperature range: ambient to 350 c energy regulator/control knob: required * power supply: 220-240 v ac, 50 hz, mortar with pestle material: porcelain size: 100 150 mm inner diameter exterior: glazed grinding surface: unglazed , hotplate top plate material: cast iron plate size: minimum 8 inch diameter power rating: 2000 w temperature range: ambient to 200 c minimum thermostatic temperature control: required power supply: 220 240 v ac, 50 hz, electric bunsen burner electrically operated energy regulator/ control knob operating temperature 800 c body: stainless steel power supply source: corded electric, supplied with a heavy-duty, heat-resistant, earth-grounded, 3-pin power cord (minimum length 1.2 meters). power consumption: between 350 and 500w power supply: 220-240 v ac, 50 hz, water distillation unit output capacity: 4 litres per hour (lph) ph value: 5.5 to 7.0 conductivity (raw water distillation):3.0 4.0 s/cm or less glassware material: borosilicate 3.3 glass (pyrex/duran equivalent) heating elements: silica enclosed quartz heaters or chromium-plated element variants power supply: 220 240 v ac, 50 hz / 60 hz, single phase automatic water level cut-off
Tender For supply of mandatory spares for chemical dosing skids , mandatory spares for oxygen dosing skids - drive shaft cum worm , drive worm wheel , connecting rod plate , cross head guide bush , plunger , plug , oil seal , washer , gland nut , electronic transmitter , transmitter of all type, ranges & model no. (for measurement of pressure, differential pressure flow, level, etc). , pressure transmitter , differential pressure transmitter , level transmitter , temperature element , local indicators like temperature gauges, pressure gauges, differential pressure gauges, flow gauges, flow meter etc. , pressure gauge , pressure gauge , diff. pressure gauge , process actuated switch devices includes all type of pressure, differential pressure, flow, , temperature, differential temperature, level switch devices. , process connection piping (for impulse piping/tubing, sampling piping/tubing and air supply piping , applicable) , valves of all types & models , 2 way, 3 way, 5 way valve manifolds , fitting , measuring instrument , electronic transmitters , transmitter of all type, ranges & model no. (for measurement of pressure, differential pressure flow, level, etc). , level transmitter (ultrasonic / radar type) , temperature element , local indicators like temperature gauges, pressure gauges, differential pressure gauges, flow gauges, flow meter etc. , process actuated switch devices includes all type of pressure, differential pressure, flow, temperature, differential temperature, level switch devices. , pd type flow transmitters , any other instrument (if applicable) , process connection piping (for impulse piping/ , valves of all types & models , 2 way, 3 way, 5 way valve manifolds , fitting , purge meter , filter regulators , mass flow controller , control valves actuators & accessories , pneumatic & electro-hydraulic actuator assembly , valve trim (including cage, plug, stem, seat ring, guide busing etc.) , diaphragm 'o' rings seals etc, all types of make etc. , pressure gauges of all types of make, rating, etc. , solenoid valves (if applicable) , positioner unit (complete unit) , pneumatic air filter/regulator of each type, makes rating etc. , air lock relays
Tender For purchase of electricals - electricals, epson eb-w53 wxga 3lcd projector, 4000 lumens full hd, built-in 16w speaker, induction stove : 2000 w, autosheet of voltage control, durable plastic body, ceramic plate touch + led display, multiple cooking mode, light weight, ups for semi auto analyzer 1 kva 800 watts, voltage 220-240 v, led display, san disk cruzer blade usb 2.0 drive 64 gb pendrive, stabilizer for refrigerator (130v-280v), power extension board with 4 power sockets, 2500 w, 8 meter cord length, 2.1a usb port 2, 250 volts, 16 ampere converter plug, 6 ampere to 16 ampere 3-pin international socket for big size 16a plug top (use 16 ampere devices in 6 ampere socket) which can be used for interactive board, microwave, refrigerator, led tube light 18 watts white (philips), 4 tb external hard disc, 3.0 external hdd-usb for windows & mac, voice amplifier for teachers with wired head set mic portable pa neckband system rechargeable with 1 neckband mic with usb, led tube light 20 w / 40w, ceiling fan 60 w, capacitor (ceiling fan 60 w), pendrive - sandisc ultra dual drive type c 256 gb otg upto 400 mb per second, heavy duty extension cord 10 meter length, 15a rating multiple sockets (3-5), water purifier aqua d pure 4 in one copper ro water purifier with 10 stage purification filtration, uv, uf, tds adjuster &12 l large storage tanker, water cooler (for approximately 150 students) : 120-150l storage 120-150l per hour cooling capacity 3 taps one ambient &two chilled water stainless steel (304) cooler with sealed compressor and eco-friendly refrigerant chilled water temperature 5-10 degree celcius, integrated inbuilt multi stage purification system with sediment filter, activated carbon filter, ro unit with minimum 50-100 lph, uv disinfection, tds controller, auomatic cut-off, overload protection, thermostat control, continuous high volume dispensing drain system (including installation - electrical & plumbing), presentation remote with laser, 2 tb portable ssd external hard disk, wireless collar mic with receiver having 6.3 mm aux male jack, external hard disk drive i tb, television 32 inch, 80 cm smart led tv, rechargeable cordless mic with voice amplifier and 6 hours or more battery life for lecture classes, 2 tb external hard disk, usb 3.0 for windows, ups 1 kva/600 w, ssa 250dp amplifier with digit, asm 580 xlr microphone, awm 700u2 wireless twin han, dgn mic stand
Tender For state plan-state plan 2025-2026-procurements of equipments for wtps-supply and installation of water quality testing equipments at wtps under ws section 1 attingal-general civil work-general civil work - purchase of jar test apparatus, od229090/2025-2026:supply and installation of the jar test apparatus must meet the following specifications. no. of. stirrers -6 minimum, rpm- 25 to 200 rpm or better, capacity of single stirrer unit-, control—digital control (digital timer & rpm counter), stirrer paddle material (with appropriate corrosion protective coating) - stainless steel, power single phase (220 - 240 volts), illumination—fluorescent tube such that illumination should not contribute heat to the system and entire equipment must have a minimum warranty period of two years, purchase of ph meter, od229087/2025-2026:supply and installation of bench top ph meter must with the following specifications: (a) regarding ph: the range must be between 0.00 to 14.00 ph or better, the resolution 0.01 or better, the accuracy 0.02 ph or better, the calibration points should be atleast 3 points, buffer option should be suitable for standard buffers. (b) regarding mv: range 0 to 1999 mv, resolution 1 mv or better, accuracy mv or better (c) regarding temperature: range 0.0 to 99 degrees celsius or better, resolution should be 0.1 degrees celsius or better, and accuracy of 0.5 degrees celsius or better. (d) the electrode of the ph meter must be a single junction, body plastic/unbreakable material, gel-filled electrode, and atc probe, and the electrode stand should also be provided by the supplier. (e) ph meter must also have lcd/led display, a dual display of ph or mv with temperature, with auto buffer recognition, offset/slope should be displayed, power 230v 10%, must provide a minimum of 100 ml of buffer solutions of ph 7.0, ph 4.0, and ph 9.2. the supplier must provide all accessories for smooth functioning of the equipment and a hard copy of the user manual with instrument specifications. the ph meter must have a minimum warranty of one year for the meter and a minimum of six months for the electrode. the calibration at the time of the installation must be done by the supplier., purchase of conductivity-tds meter, od229088/2025-2026:supply and installation of conductivity - tds meter with conductivity range of at least 0.1 s to100 ms, resolution : 0.001 s and tds range of 0.1 ppm to 100 ppt , temperature : 0 degree celsius to 1000 degree celsius (auto / manual), readout : 7 digits led (3 digits for temp. and 4 digits for cond./tds), printer interface for 80 column d.m. printer with minimum one year warranty
Tender For the offered equipment is a fiber media converter, model gomc-bi3512-20 or equivalent , designed for conversion between 10/100/1000base-tx copper ethernet and 1000base-fx optical fiber networks. the converter supports ieee 802.3, ieee 802.3u, ieee 802.3ab and ieee 802.3z standards, ensuring compatibility with gigabit ethernet networking applications. it provides one rj45 copper port with auto-negotiation support for 10/100/1000 mbps data rates and one sc type bi-directional fiber port operating at tx 1310nm / rx 1550nm wavelength with transmission distance up to 20 km over single-mode optical fiber. the device supports full duplex flow control and half duplex back pressure for efficient data transmission. led indicators are provided for power, optical link/activity, full duplex status, twisted pair link/activity and transmission rate indication. the converter operates on dc 5v, 1a power supply with optional external or internal power supply configuration and power consumption less than 3w. it is designed to operate in environmental conditions ranging from -10?c to +55?c with storage temperature from -40?c to +85?c and relative humidity from 5% to 95% non-condensing. the unit dimensions are 94mm ? 70mm ? 26mm for external type and 140mm ? 110mm ? 30mm for internal type. the product is suitable for network communication, ftth/fttb/fttx applications, isp backhaul networking and subscriber end connectivity. the equipment complies withce, fcc and rohs certifications. [ warranty period: 36 months after the date of delivery ] ]
Tender For rate contract for 02 years (extendable) for purchase of biomedical waste sharps-blaster/disposable destroyer system and consumables for central store - sharp disposable destroyer system sharps balster sterilization unit(needle blaster) for treatemtn of biomedical waste category-iv make- safe environment solutions the unit is a desktop sized, simple plug & use type which converts the potentially hazardous sharps and syringes form blue bag category to black bag category at the touch of a button the unit is "ce approved". it is also approved by central pollution control board. it has also being recommended by w.h.o. the desk top solution is safe & environmentally friendly for the decontamination of sharps & other soft clinical wastes using non burn technology. machine is portable & can be installed in any part of the hospital without any extra utility requirement, operating on ordinary 230v ac. it effectively prevents second stick injuries which is a major concern as per who reports. user friendly & cost effective using very less power. sharp disposable destroyer consumables disposable canister, disposable 3 to 5 lit. metal canisters to collect the sharps or soft clinincal waste (needles, syringes, scalpel blades etc.) to be heated up to two and a half hours at temperature reaching 185'. canister should be lockable. , sharp disposable destroyer consumables disposable insert it is ldpe, pvc free inserts for sharp disposable destroyer unit. , sticky back paper label roll: thermal paper roll, 100 sticky back stickers per roll for sharp disposable destroyer unit. , active carbon filter active carbon filter for fume's entrapment, minimum 5 inch length, both ends open with suitable sealing gaskets.
Tender For purchase of equipment - purchase of equipment: dual pump nanofiber electrospinning unit, 1. high voltage power supply output: 0 40 kv, positive & negative polarity, digital control with current limiting and safety interlock2. syringe pump system dual syringe pumps, upgradeable to triaxial (3) or four (4) syringe configuration flow rate range: 0.001 20 ml/hr, compatible syringe size: 1 60 ml3. spinneret system stainless steel needles (18g 30g) capability for single, coaxial and triaxial electrospinning, multi-needle spinning provision4. collector system interchangeable flat plate and rotating drum collectors (different sizes), drum speed: 0 5000 rpm adjustable tip-to-collector distance: 5 30 cm5. environmental control chamber fully enclosed electrospinning chamber, temperature control: ambient 60 c humidity control: 20 80% rh6. control & automation touchscreen / pc-based operation, programmable process parameters real-time monitoring of voltage, flow rate, collector speed, temperature and humidity7. digital interface & data handling advanced digital interface for system control, high data storage capacity for experimental records data export through usb / ethernet8. safety features, fully grounded system door interlock for high-voltage safety emergency stop and overload protection9. accessories & support syringes, needles, grounding cables and collector substrates, on-site installation and user training, operation manual warranty: minimum 2 year