Get complete information related to latest Overhead Gantry Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Overhead Gantry Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Overhead Gantry Tenders.
Tender For supply of led rechargeable flood light 50 watt having die cast aluminium enclosure & ms epoxy coated structure, designed for max efficiency /rugged construction with toughened glass & water proof protection ip65, highly reliable lithium ion battery with battery backup of 4 hours in normal mode, 8 hours in low mode & 2 hours in turbo mode. high power industrial, service value 50000 hours, cri > 80%, cct 6500k, heatresistance and toughened glass, thermal management design for nest thermal life with metal mounting bracket, adjustable beam light direction & ac charger with one-year warranty. preferred make -mimic, wipro, philips, fos, oreva.or equivalent. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : construction of transformer plinth with overheadgantry crane, cc road, paver block & demolition of old quarters and transformer plinth at una ph campus under amreli circle.
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlocking bricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty air circulators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four pole structure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49