Get complete information related to latest Overhead Line Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Overhead Line Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Overhead Line Tenders.
Tender For replacement of infringing lt overheadline by lt cable and modification in lighting arrangement in rkmp, bpl and guna yard in connection with electrification of unelectrified siding.
Tender For modification and shifting of 220 kv and 132 kv transmission lines of mpptcl passing through submergence area of kanyakhedi irrigation project
Tender For corrigendum : bi-annual rate contract (arc) for restoration of 66kv h frame transmission lines damaged due to natural calamity or in any emergency under navsari circle.
Tender For corrigendum : bi-annual rate contract (arc) for restoration of 132kv tower transmission lines damaged due to natural calamity or in any emergency situations under navsari circle.
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overheadline & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : establishing of 2x160mva, 220/110kv and 1x10mva, 110/11kv substation at chadchan (devar nimbaragi) in chadachan taluk, vijayapura district with kiosk based arrangement along with construction of associated 220kv transmission line for a distance of 29.628km and 110kv lines for a distance of 60.78km along with construction of 2 nos of 220kv terminal bays and 05 nos of 110kv terminal bays on partial turnkey basis, including supply of all materials/equipments (excluding supply of 1x10mva,110/11kv power transformer & 11kv switchgear), erection (including dismantling and civil works) of all materials/equipments, testing and commissioning
Tender For corrigendum : supply of various type of towers for 400kv and 220kv transmission lines - tower ht dc type tp 1 , tower ht dc type tp 2 , tower ht dc type tp 3 , tower ht dd normal tower 4 , tower ht dd+0mbe 5 , tower ht dd +9mbe 6 , ht basic body sb type tower 7 , ht +3mbe sb type tower 8 , tower ht dd type 9 , tower ht da normal tower 10 , tower ms dc type tp 11 , pack washers for dc type tp 12 , tower ms dc type tp 13 , pack washers for dc type tp 14 , tower ms dc type tp 15 , pack washers for dc type tp 16 , tower ms dd normal tower 17 , tower ms dd+0mbe 18 , tower ms dd +9mbe 19 , ms basic body sb type tower 20 , ms +3mbe sb type tower 21 , tower ms dd type 22 , tower ms da normal tower 23 , n&b incl spring washers for dc type tp 24 , n&b incl spring washers for dc type tp 25 , n&b incl spring washers for dc type tp 26 , tower nand b dd normal tower 27 , tower nand b dd+0mbe 28 , tower nand b dd +9mbe 29 , nand b for basic body sb type tower 30 , nand b incl spring washers sb type tower 31 , nand b incl spring washers for dd type 32 , tower nand b da normal tower 33 , stub ht for dc type tp 34 , stub ht for dc type tp 35 , stub ht for dc type tp 36 , stub ht for dd+9 tower 37 , stub ht +1mtr rc for dd+9 tower 38 , stub ht sb type tower 39 , stub ht for dd type 40 , stub ht for da type 41 , stub ms for dd+9 tower 42 , stub ms +1mtr rc for dd+9 tower 43 , stub ms sb type tower 44 , stub ms for da type 45 , stub nand b for dc type tp 46 , stub nand b for dc type tp 47 , stub nand b for dc type tp 48 , stub n and b for dd+9 tower 49 , stub nand b +1mtr rc for dd+9 tower 50 , stub nand b sb type tower 51 , stub nand b for dd type 52 , stub nand b for da type 53
Tender For corrigendum : for provide knowledgeable skill person to overseers 11kv/22kv underground cable/overheadline network for route patrolling, cable safe guarding, cable fault joint pit excavation etc. to identify hazardous/accident prone t/c and vulnerable location and other activities as per instruction of engineer in charge under navsari rural division (all subdivisions)