Web Analytics Made Easy - StatCounter

Overload Protector Tenders

Get complete information related to latest Overload Protector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Overload Protector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Overload Protector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45261444 Due date: 22 Jul, 202622 Jul, 2026 NA
Tender For corrigendum : tender for supply of aft hydroplane sensor , fwd hydroplane sensor , quick acting fuse type d1 size 5x20mm model ha21 0 5a 220v , fast blowout fuse cartridge type 1d 5x20mm model ha21 5a , quick blowout fuse type d1 size 5x20mm model ha21 3 15 a , quick acting fuse type d1 size 5x20mm model ha21 0 1a 220v , track baller , polypropylene film capacitor metallised 10af1 , pre charge contact switch cap 200 12 900vdc 500a , pre load power resistor , temperature probe ctn 10k , capacitor metallis polypropylene filme2 2uf850vdc450veffaxial , polypropylene film capacitor metallised 10uf600vdc330veffaxial , polypropylene film capacitor 10nf 3000vdc axial , capacitor polypropylene film filtering mli 22f 660v , feed through capacitor 500a 700vdc 600vav 250nf , base female metal w o clipds9ip553p t150a115v60hzwithtie , power contact 1 f 350a 750vcc 1 auxiliary contact 1 f , thyristor housing unit semipack4 1thyristor1200v400a , fast fuse 14 51 380vdc 4a high cutt off power

CTN :45648625 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For supply and installation of auto-power overload protector in mechanical press. model: ae-12a make:

CTN :45664072 Due date: 28 Jul, 202628 Jul, 2026 NA
Tender For supply of load resistor to primary voltage transformer to spec. clw/es/3/0024 alt.- a, and str no. clw/2022/eldo/e/str/0139 rev- 0 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

State Government

CTN :45599641 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For supply of spares for anupam make eot crane (135t / 30t) installed at tg-floor (a-b bay) and (70t) crane at cw pump house of 1 x 800 mw unit-8 at wtps. - shrouded dsl- 315a, 4 al for anupam make 135/30t main turbine eot crane, dsl centre power feed for anupam make 135/30t main turbine eot crane, dsl current collector for anupam make 135/30t main turbine eot crane, double current collector bracket for anupam make 135/30t main turbine eot crane, dsl phase indicator for anupam make 135/30t main turbine eot crane, 415/240v, 2000va transformer for cabin ac for anupam make 135/30t main turbine eot crane, 415/240/24v, 2500/250va lighting transformer for anupam make 135/30t main turbine eot crane, 4p, 2w changeover switch for control transformer for anupam make 135/30t main turbine eot crane, 415/110v, 1500va control transformer for anupam make 135/30t main turbine eot crane, radio remote control for anupam make 135/30t main turbine eot crane, foot switch 1no+1nc for anupam make 135/30t main turbine eot crane, counter weight limit switch 1no+1nc for main hoist (mh) for anupam make 135/30t main turbine eot crane, counter weight limit switch 1no+1nc for auxilairy hoist (ah) for anupam make 135/30t main turbine eot crane, main power contactor 110v, 110a for anupam make 135/30t main turbine eot crane, rope tension type load cell system for anupam make 135/30t main turbine eot crane, main sfu with 160a fuse link for anupam make 135/30t main turbine eot crane, on-delay, off-delay, single shot timer for anupam make 135/30t main turbine eot crane, input line choke 0.1327mh, 100a for main hoist (mh) for anupam make 135/30t main turbine eot crane, main hoist braking unit bu-37-4c for main hoist (mh) for anupam make 135/30t main turbine eot crane, main hoist dynamic breaking wire wound resistor for main hoist (mh) for anupam make 135/30t main turbine eot crane, main hoist sfu with 125a fuse link for main hoist (mh) for anupam make 135/30t main turbine eot crane, main hoist eht brake 300 dia, 62kgm, mdt type for main hoist of anupam make 135/30t main turbine eot crane, main hoist brake economy resistance for main hoist of anupam make 135/30t main turbine eot crane, incremental encoder for main hoist of anupam make 135/30t main turbine eot crane, 12v encoder card opc g1 for main hoist of anupam make 135/30t main turbine eot crane, master controller for main hoist of anupam make 135/30t main turbine eot crane, rotary geared limit switch for main hoist of anupam make 135/30t main turbine eot crane, input line choke 0.1327mh, 100a for auxilairy hoist (ah) for anupam make 135/30t main turbine eot crane, auxiliary hoist braking unit bu-37-4c for auxilairy hoist (ah) for anupam make 135/30t main turbine eot crane, auxiliary hoist dynamic breaking wire wound resistor for auxilairy hoist (ah) for anupam make 135/30t main turbine eot crane, auxiliary hoist sfu with 100a fuse link for anupam make 135/30t main turbine eot crane, auxiliary hoist eht brake 200 dia, 32kgm, mdt type for auxiliary hoist (ah) of anupam make 135/30t main turbine eot crane, incremental encoder for auxiliary hoist of anupam make 135/30t main turbine eot crane, 12v encoder card opc g1 for auxiliary hoist of anupam make 135/30t main turbine eot crane, master controller for auxiliary hoist of anupam make 135/30t main turbine eot crane, rotary geared limit switch for auxilairy hoist of anupam make 135/30t main turbine eot crane, input line choke 0.1104mh, 13a for cross travel (ct) for anupam make 135/30t main turbine eot crane, cross travel eht brake 160 dia, 9kgm, mdt type for cross travel (ct) of anupam make 135/30t main turbine eot crane, cross travel dynamic breaking wire wound resistor for cross travel (ct) for anupam make 135/30t main turbine eot crane, cross travel sfu with 32a fuse link for cross travel (ct) for anupam make 135/30t main turbine eot crane, auxiliary relay 24vdc, 6a for cross travel (ct) for anupam make 135/30t main turbine eot crane, master controller for cross tra

Central Government And Public Sector

CTN :45597647 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For supply of load resistor to primary voltage transformer as per specification. no. clw/es/3/0024/a or latest specn: clw specification. no. clw/es/3/0024/a or latest [ warranty period:30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45541202 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For purchase of tanche - lab equipments for eee and ece department - purchase - lab equipments for eee department electronics lab, single phase to single phase cyclo converter kit single-phase bridge cycloconverter power devices: scr/triac based input supply: 230 v ac, 50 hz step-down isolation transformer 230 v / 12 v output: 12 15 v ac, frequency: 0 25 hz (adjustable),firing angle control circuit and frequency control circuit to be provided built-in resistive load, terminals to be brought on ms panel with necessary symbols and circuits, pwm based step down dc chopper using mosfet/igbt kitpwm based step-down dc chopper (buck converter) power device : power mosfet / igbt based switching circuit input supply : 24 v dc to 110 v dc or derived from 230 v ac mains through rectifier unit output voltage :(0 to vin) variable dc output current : up to 5 a dc maximum with suitable load resistor (r load) pwm duty cycle control provided pwm generation and control circuit inbuilt gate driver circuit provided, single phase single pulse / sinusoidal pwm inverter using mosfet/igbt kittype : single phase pwm inverter trainer power device : mosfet / igbt based inverter circuit input supply : 12 24 v dc output voltage : 30 v rms ac output phase : single phase output frequency : 0 50 hz variable output power : 100 w single pulse pwm operation sinusoidal pwm (spwm) operation variable frequency control pwm generation and firing control circuit inbuilt gate driver circuit provided test points provided for waveform observation and analysis built-in resistive load provision, on / off control of lamp using solid state relay kittype : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status, speed control of ac motor using vfd drive module with ac motortype : variable frequency drive (vfd) module input supply : 415 v ac, three phase, 50 hz output : three phase variable voltage and variable frequency ac output 1 hpthree phase squirrel cage induction motor415 v ac 50 hz &1440 rpm control technique : pwm / spwm based control frequency range : 0 50 hz variable digital display for frequency and operating parameters start / stop and forward / reverse control, acceleration and deceleration control facility powder coated ms control panel tabletop / floor mounted laboratory type setup clearly labelled circuit diagram and control switches proper insulated terminals and earthing arrangement, purchase - lab equipments for eee department electrical machines lab, three phase transformertype: three phase transformer, rating: 3 kva input voltage: 415 v ac, 3-phase, output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory usebench/floor, dc stepper motor drive kit with stepper motorinput supply : 230 v ac, 50 hz stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection., dc servo motor drive kit with servo motorinput supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive contr

Central Government/Public Sector

CTN :44928451 Due date: 28 Apr, 202628 Apr, 2026 NA
Tender For on load tap changer as per annexure a - on load tap changer type (miii-700-110/c-10193w) with motor drive unit, oil surge relay, bevel gear & drive shafts as per specification of oltc enclosed., tie-in-resistor (tir), prv

Central Government/Public Sector

CTN :44947116 Due date: 27 Apr, 202627 Apr, 2026 NA
Tender For 1.5 ton ac, inverter type split air conditioners suitable for operation on a/c supply single phase 50 hz 230v with hermetically sealed inverter compressor with air cooled condenser latest r410a/r-32 refrigerant fan motor, start & run capacitors, relay & overload protector internal unit with one indoor & one outdoor unit. the condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube and suitable capacity 3 core sheathed/ pvc copper cable and a battery operated wireless remote unit and outdoor stand. (detailed specification is as per enclosed spec copy) [ warranty period: 12 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up