Web Analytics Made Easy - StatCounter

Overload Protector Tenders

Get complete information related to latest Overload Protector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Overload Protector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Overload Protector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

corporations/Associations/Others

CTN :45702242 Due date: 07 Jul, 202607 Jul, 2026 17.03 Lacs
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh

CTN :45723969 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For electricity distribution block and head] c.t.p.t. unit of various relays in the area of work of sitapur] metering cubicle p.t.] electrical sub-station etc. material of electricity storage center sitapur to electrical test section sitapur and from electrical test section sitapur to the site work of installation designation jim rntpekpabjpvd vf mmm. appjanchanat

CTN :45399903 Due date: 06 Jul, 202606 Jul, 2026 7.53 Lacs
Tender For corrigendum : supply of printed stationery items at stps, suratgarh. - pay bill gazzetted (pad of 100 sheet) , orderly and thermal allowance (pad of 100 sheet) , pl application form (pad of 100 sheet) , absentee statement (pad of 100 sheet) , covering letter (pad of 100 sheet) , hr performa (pad of 100 sheet) , pcb voucher (pad of 100 sheet) , nac (not available certificate) (pad of 100 sheet) , acr form for tech staff (pad of 100 sheet) , ot decleration sheet (pad of 100 sheet) , medical reimbursement(pad of 100 sheet) , fvc form (pad of 100 sheet) , indent book cos-17-18 , field register (of 100 sheet) , ot book in triplicate , receipt register (of 100 sheet) , dispatch register (of 100 sheet) , stock register 370 p+15 index , stock register 170 p+ 15 index , vehicle driver log (book of 100 sheet) , c-1 register (size20"x15") (register of 100 sheet) nge , peon book (size 8.5"x6.75") (book of 100 sheet) , c-2 register (size 10"x15") , mrc register(of 100 sheet) , ta bill form (gazetted) (pad of 100 sheet) , pcb , c-5 , register , defect log book (of 100 sheet) , permit issue register (of 100 sheet) , attendance register size 10"x15" (of 14 sheet) , cash book register , work identification memo book , electricity no-dues certificate (of 100 sheet with dublicate copy, book no and page no. , memo for payment , cash book of account , journal voucher (emd to sd convertation) , journal voucher (adjustment) , card sheet for monthly payment for each work order (pink , service book (100 pages) size 8" x 13" , dc register (8.5"x13.5") , sg register (8.5"x13.5") , daily generation data register (register of 100 sheet) , generation loss register (register of 100 sheet) , ems of xen store wings , pcb covering letter(pad of 100 sheet) , cos-15 mcn book , store inward register cos -6 , supply bill covering letter , arranging inspection letter , supply completion report(for store use)( , priced srn / sin cover letter , srn book , gate pass book (store) , cos-14 (100 sheet) ledger with index a to z (13.5"x17") , bin cards (small card) (material identification card) size 7.33"x4.67" , cos-23 register (scrap) , cos-14 (200 sheet) ledger with index a to z (13.5"x17") , ems of s.e. operation support wing , control room fans panel log sheet unit-1st/2nd/3rd/4th/5th/6th , control room mill log sheetunit-1st/2nd/3rd/4th/5th/6th , control room steam & water log sheetunit-1st/2nd/3rd/4th/5th/6th , control room turbine panel log sheet unit-1st/2nd/3rd/4th/5th/6th , control room generator panel log sheet unit-1st/2nd/3rd/4th/5th/6th , boiler operating floor (19.5meter) log sheet , id/fd/pa fans log sheet unit-1st/2nd/3rd/4th/5th/6th , mills area log sheet unit-1st/2nd/3rd/4th/5th/6th , boiler feed pump area log sheet unit-1st/2nd/3rd/4th/5th/6th , turbine operating floor / lub oil pump /oil coolers centrifuge log sheet unit-1st/2nd/3rd/4th/5th/6th , condensate extraction pump log sheet , hydrogen seal oil system log sheet unit-1st/2nd/3rd/4th/5th/6th , esp log sheet unit-1st/2nd/3rd/4th/5th/6th , ht (6.6 kv) lt (415 v) switch gear log sheet , cooling tower log sheet unit-1st/2nd/5th , compressor plant log sheetunit-1st/2nd/3rd/4th/5th , compressor plant log sheet unit-6 , 400kv switch yard transformer log sheet , 400kv switch yard log sheet , raw water log sheet stage-1/2/4 , assistant engineer (boiler) log book u#1 to 6 , assistant engineer (ca & elect) log book u#1 to6 , assistant engineer (turbine) log book u#1 to 6 , diesel generator register , ptw book in duplicate (9"x11') , meeting agenda register , ca equipment running hrs. register , raw water running hrs register , boiler/turbine equipments running hours register , tripping register , boiler/turbine/ca & electrical reading register , sadc register , day tank of fuel oil logsheet , 220 kv switch yard logsheet , dmccw system stage- 2nd/3rd/4th log sheet , c.w/a.cw pump house area stage -2nd/3rd/4th log sheet , intake pump house logsheet , shift incharge log book , details of gun clea

State Government

CTN :45573763 Due date: 06 Jul, 202606 Jul, 2026 1.99 Lacs
Tender For corrigendum : supply of material required for operation and maintenance of various 132/33 kv sub-stations under electricity transmission division-ii, basti h.q. at siddharth nagar

Central Government/Public Sector

CTN :45702701 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For auction sale of rolling stock - condemned and unserviceable bg demu coach no. special repair dpc 008073 with available items [refer enclosure for the material composition]. location: coach care centre tpj/diesel loco shed goc. custodian: sse/demu/diesel shed/goc. re-claimable items - [1] wheel sets with bull gear-04 sets [2] 8v 450ah lead acid battery-03 nos [3] 6v batteries-18 nos [4] truck assembly-02 sets [5] axle box with bearings-08 nos [6] buffer complete-02 nos [7] schaku coupler assembly[draw bar with hook, draft gear assembly]-01 set [8] brake cylinders-04 nos [9] wear pieces(brass)-04 nos [10] dpc main doors-02 nos. advice note no.073817-25-08698, dt: 11.12.25. note-[1] delivery to be made on as is where is and lot basis.[2]the location indicated is only tentative. railway reserves the right to change the location of sold coach, based on the availability of track, cutting and loading space and other administrative reason, as deemed fit by the auction conducting officer.[3]gas/chisel cutting is permitted only to sizes that are loadable with a crane, only after ensuring sufficient safety measures against fire hazards etc. to avoid any mishap to any person, railway material etc. and the same should be ensured by the witnessing officials.[4]in case purchasers require usage of any railway assets/materials such as electricity/forklift truck etc. during the process of delivery, they are required to pay the prescribed amount to railways, as directed by the respective custodian of the lot. special condition- [1] reclaimable item as said above in description of the lot, should be returned to the custodian before commencing delivery. [2] in order to make the assessment, the purchaser may visit the coach offered for condemnation and the site conditions before quoting the offer.[3] the purchaser has to make his own arrangements such as tools, lifting tackles, lifting equipment, gas cutting equipment. [4] the weight and quantities were taken into consideration as advised by the custodian [5] the purchaser may note that reclaimable items of coach are to be stripped instead of gas cutting to avoid damage to rc items and the purchaser should make such arrangements, especially traction motors should be removed by using proper tools and equipments without causing damage to truck assembly [6] the purchaser is strictly instructed to transport/stack all the reclaimable items at one location well away from the cut off parts of the coach as directed by the custodian. [7] the purchaser will be held responsible for any damage/fire accident caused to the railway property. [8] railway is not responsible for any shortage.[9] after completion of delivery, purchaser has to keep the cutting and loading spot neat and clean, free of any left over coach scrap. [10] railways does not guarantee for quality, quantity description etc.[11] delivery should commence immediately after cutting without any delay. [12] the courts in chennai alone shall have exclusive jurisdiction in the matters/disputes arising out of the contract/arbitration/conciliation proceedings and the place of arbitration/conciliation, if any, shall be in chennai only. [13] bsv partly paid along with emd will be forfeited, if full payment is not received in stipulated time, with interest if any applicable. [14] part delivery is not permitted against part payment. [15] if any hsd oil/lube oil available in fuel tank/oil sump of the said coach, the same may be returned to the custodian.(location: coach care centre tpj / diesel loco shed goc)

CTN :45683346 Due date: 30 Jun, 202630 Jun, 2026 5.00 Lacs
Tender For 7 work - tent arrangement , light decoration work on fair and festival. , big jcb machine with operator, complete supply work. , hoardings, flex banner work. , snacks and sweets arrangements. , tractor with trolley complete supply work on rent. , material supply work for electricity system in the municipality area.

CTN :45648625 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For supply and installation of auto-power overload protector in mechanical press. model: ae-12a make:

State Government

CTN :45653863 Due date: 30 Jun, 202630 Jun, 2026 11.22 Lacs
Tender For supply of required materials as per tender specifications for execution of time-to-time maintenance works in installations and lines under electricity distribution sub-division, khatima (o and m head). - supply of following decentralised material as per upcl respo., connection suit for stud m20 cable, 400 sq.mm., 100 watt led street light with accessories, connection suit for m20 cable, 630 sq.mm., 11 kv straight through jointing kit for 3 120 sq.mm xlpe cable, 33 kv heat shrink cable end termination kit for 3 400 sq.mm (o/d), 33 kv xlpe heat shrink straight through jointing kit for 3 400 sq.mm, 11 kv xlpe heat shrink straight through jointing kit for 3 240 sq.mm, 11 kv heat shrink kit for 3 120 sq.mm (outdoor type), 11 kv heat shrink kit for 3 70 sq.mm (outdoor type), 11 kv heat shrink cable jointing kit for 3 240 sq.mm (outdoor type), m-seal compound, brass nut 20 mm, pvc insulation tape, ht (high tension) tape, fuse wire
 Loading, Please wait...

Connect us via What's Up