Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For supply, installation and commissioning of portable flue gas analyzer for thedetermination of oxygen (o2), carbon dioxide (co2), carbon monoxide (co andco low), nitric oxide (no & no low), nitrogen dioxide (no2), hydrogen sulphide(h2s), hydrocarbon(hc), sulphur dioxide (so2), temperature, efficiencyand pressure in flue gas stack outlet and other gas samples. technicalspecifications strictely as per attached annexure 1 and 2
Tender For corrigendum : supply of veterinary instruments and equipments - allis tissue forceps (20 cm.), artery forceps curved (15 cm ), artery forceps straight (15 cm ), forceps s.s. (20 cm), forceps s.s.(15 cm), haemostat straight s.s.(17.5 cm), haemostate curved s.s. (15 cm. ), mayo s scissors curved isi (s.s. 15cm), mayo s scissors straight isi (s.s. 15cm), scissors straight s.s.(12.5 cm), scissors straight s.s.( 17.5 cm), surgical gloves (standard), surgical mask (standard), suturing needle (assorted size) (traumatic/atraumatic cured/st.), suture thread silk/ nylon (10 mt. reel no.100, 0, 1, 2, 3), chromic cat gut (100, 0, 1, 2, 3 no.), needle holder s.s.(15cm), instrument trolly, dressing drum s.s. round 20 gauge (height 30cmx30cm dia.), b.p. blades (no. 22, 23, 24, 11, 12, 13,14, 16, b.p. handle s.s.(no. 3 ), b.p. handle s.s.(no. 4), kidney tray s.s.(15 cm length), tray small ss (250mmx300mm), hypodermic needle (15 x3/4"), hypodermic needle (18 x3/4"), vaccutainer with needle (with vacuum, 10 ml and needle of double bewell 16 no.), electrcally operated needle and syringe destroyer. destruction rate max. 1 minute per needle of 1.6 mm thickness with 80 mm length. min. 350 cutted hubs of syringes with needle burnt residue., bloodless castrator for small animals 9 (made of special high carbon steel coated for protection against rust formation), castrator imported, i/v fluid stand (s.s.), intra venous set (disposable 0 standard) ), scalp vein set (21 no. 0 22 no.), electric dehorner (30 cm length), trocar canula for sheep s.s.(15 cm), teat syphon (ss), drenching bottle (large) (metal 500 m), drenching bottle (small) (metal 200 ml), doctor coat tericot (free size), plastic apron, macentosh sheet (double colour), rubber arm sleeves with latex gloves (no. 9), gum boot, dog muzzle (assorted size), dog nail cutter (standard), measuring cylinders (50 ml graduated borosil glass ), measuring cylinders of (100 ml graduated borsil glass ), medicine carry bag (nylon 600 dpu coated padded, multipocket for medicine and surgical equipments ), jar with lid ss (2 kg. capacity), jug ss (2 ltr. cap.), thermos s.s. double insulated (1 ltr. cap., 30cm length, 7.5cm mouth dia with soulder carrying strap.), bucket ss (12 ltr capacity), california mastitis kit, centrifuge machine (bench top) for general purpose, canopy tent with carrying bag. frame made of steel powder coated pipe (23 gauge) 0 tetron cover (waterproof) with two folding chairs and one folding table, vaccine carrier (1.6 lit capacity with 4 ice packs), microscope binocular, autoclave electric, calf puller ss 316/304., animal catching device, cold boxes vaccine storage capacity 20 ltr. weight fully loaded 43.3 kg. empty weight 17.5 kg. external surface material plastic, internal lining material plastic , insulation material polyurathene, insulation thickness 110 mm,, refrigerator, thermocautery, veterinary urine analyzer with accessories, animal sling for large animals, cold cabinet/ cold room with 25% capacity of racks as deep freezer and 75 % as cold cabinet having 2-8 degree celcius temperature, digital display, alarm system for temp. beyond set point, hematology analyzer with accessories (three parts), semi automatic veterinary serum analyzer with accessories, verticle cold cabinets for vaccine storage, with storage temperature 2-8 degree celcius. temperature holding time atleast 12 hrs, at power failure. adjustable shelves., hot air oven, incubator, ice liner (ice lined refrigerator or freezer) compressor compartment0 hermetically sealed high quality compressor 230 v 50/60 hz. relatively noise less fan to cool down the compressor. all steel tubes protected with special compound against rust formation. 1 thermostate pre-stetted from the factory for 2 c - 8 . control panel situated at the front of the unit. light indicators for different functions, 1 digital thermometer to indicate the internal temperature, latest cooling system. insulation with thick polyurethane foam. foaming agent- cyclo