Tender For purchase of gym for strength and conditioning equipments - endurance sectiontreadmill1. machine must be designed for running with heavy duty 4 hp motor.2. should have low start up speed: 0.5 kmph or lesser.3. should have incline increments of 1% or lesser.4. low step height: 7 or lower.5. speed range: 0-20 kmh or more.6. incline: 0-15% or more.7. max user weight: 180 kgs or more.8. belt size : 61 x 22 or more9. should have at least 10 preprogrammed protocols with option for heart rate range control10. led console with feedback for time distance, calories burnt, heartrate, incline, track and more product should have en-957 or astm certification for stationary fitness equipment, curved non- motorized treadmill (self- powered)1. curved non-motorized treadmill should be capable of training the body s all energy systems as a comprehensive system, capable of offering sprinting for aerobic power development2. curved non- motorized treadmill (self powered) should be capable of offering the sports persons to experience a full speed resistance spectrum.3. variable resistance: the curved non- motorized treadmill (self powered) system should have requisite advanced drive technology enabling users to select different levels of reactive resistance, from zero to max. by simply shifting the drive control system, rehab athletes can quickly switch from resistance-free running to an all-out sled push.4. increased metabolic rate: walking with resistance on said curved non-motorized treadmill (self powered) training system should be capable of enhancing energy expenditure significantly compared to walking at the same speed on a traditional treadmill or a non- motorized treadmill without resistance.5. maximum muscle activation: ergonomic design of the curved non-motorized treadmill (self powered) training system should lead to significantly higher activation of the posterior kinetic chain muscles, particularly the glutes and hamstrings, compared to traditional treadmills.6. curved non-motorized treadmill (self powered)- training system should be capable of being operated and controlled exclusively by the force applied / generated by rehab athletes. in order to speed up, provision should be there, where rehab athlete can move to the front of the surface and to slow down, rehab athlete can move to the back of the said treadmill. provision must be there where the training system can be accelerated quickly from a cold start and matches upto the same pace as the rehab athletes intends to attain. the said system should offer an ideal solution for an eco-sustainable facility, by reducing electricity costs and carbon footprint.7. training system should have requisite technology, ergonomic design and advanced engineering solution so that rehab athletes can work hard in a completely safe training environment.the ergonomic design combined with the high- quality components and materials should be of solid, compact product with a versatile nature that endures well to suit high intensity prolong training sessions to ensure maximum durability and reliability.8. provision for proper posture control:the ergonomic design of training system promotes the correct alignment of the ankles, knees, hips and back, so that user can maintain natural posture at all- times and avoid joint and knee stress, regardless of their height and weight. system should offer the provision of simulating the experience of walking/running uphill while preserving the correct biomechanics.9. accessory kit: the training system must be provided with accessory kit which allows for a variety of pulling and pushing exercises through handles or a waist belt.10. technical specifications:a) dimensions range (lxwxh)*:190-200cmx86- 95cmx150-160cmb) console type: a minimum of 6-7 lcd display with back lightc) power supply: lps 5v wall supplyd) power requirement: 200 - 240 v (should comply with standard indian electrical system)e) resistance control: should have magnetic resistance with a minimum of 8-10 l
Tender For purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- validation and te
Tender For corrigendum : supply of veterinary instruments and equipments - allis tissue forceps (20 cm.), artery forceps curved (15 cm ), artery forceps straight (15 cm ), forceps s.s. (20 cm), forceps s.s.(15 cm), haemostat straight s.s.(17.5 cm), haemostate curved s.s. (15 cm. ), mayo s scissors curved isi (s.s. 15cm), mayo s scissors straight isi (s.s. 15cm), scissors straight s.s.(12.5 cm), scissors straight s.s.( 17.5 cm), surgical gloves (standard), surgical mask (standard), suturing needle (assorted size) (traumatic/atraumatic cured/st.), suture thread silk/ nylon (10 mt. reel no.100, 0, 1, 2, 3), chromic cat gut (100, 0, 1, 2, 3 no.), needle holder s.s.(15cm), instrument trolly, dressing drum s.s. round 20 gauge (height 30cmx30cm dia.), b.p. blades (no. 22, 23, 24, 11, 12, 13,14, 16, b.p. handle s.s.(no. 3 ), b.p. handle s.s.(no. 4), kidney tray s.s.(15 cm length), tray small ss (250mmx300mm), hypodermic needle (15 x3/4"), hypodermic needle (18 x3/4"), vaccutainer with needle (with vacuum, 10 ml and needle of double bewell 16 no.), electrcally operated needle and syringe destroyer. destruction rate max. 1 minute per needle of 1.6 mm thickness with 80 mm length. min. 350 cutted hubs of syringes with needle burnt residue., bloodless castrator for small animals 9 (made of special high carbon steel coated for protection against rust formation), castrator imported, i/v fluid stand (s.s.), intra venous set (disposable 0 standard) ), scalp vein set (21 no. 0 22 no.), electric dehorner (30 cm length), trocar canula for sheep s.s.(15 cm), teat syphon (ss), drenching bottle (large) (metal 500 m), drenching bottle (small) (metal 200 ml), doctor coat tericot (free size), plastic apron, macentosh sheet (double colour), rubber arm sleeves with latex gloves (no. 9), gum boot, dog muzzle (assorted size), dog nail cutter (standard), measuring cylinders (50 ml graduated borosil glass ), measuring cylinders of (100 ml graduated borsil glass ), medicine carry bag (nylon 600 dpu coated padded, multipocket for medicine and surgical equipments ), jar with lid ss (2 kg. capacity), jug ss (2 ltr. cap.), thermos s.s. double insulated (1 ltr. cap., 30cm length, 7.5cm mouth dia with soulder carrying strap.), bucket ss (12 ltr capacity), california mastitis kit, centrifuge machine (bench top) for general purpose, canopy tent with carrying bag. frame made of steel powder coated pipe (23 gauge) 0 tetron cover (waterproof) with two folding chairs and one folding table, vaccine carrier (1.6 lit capacity with 4 ice packs), microscope binocular, autoclave electric, calf puller ss 316/304., animal catching device, cold boxes vaccine storage capacity 20 ltr. weight fully loaded 43.3 kg. empty weight 17.5 kg. external surface material plastic, internal lining material plastic , insulation material polyurathene, insulation thickness 110 mm,, refrigerator, thermocautery, veterinary urine analyzer with accessories, animal sling for large animals, cold cabinet/ cold room with 25% capacity of racks as deep freezer and 75 % as cold cabinet having 2-8 degree celcius temperature, digital display, alarm system for temp. beyond set point, hematology analyzer with accessories (three parts), semi automatic veterinary serum analyzer with accessories, verticle cold cabinets for vaccine storage, with storage temperature 2-8 degree celcius. temperature holding time atleast 12 hrs, at power failure. adjustable shelves., hot air oven, incubator, ice liner (ice lined refrigerator or freezer) compressor compartment0 hermetically sealed high quality compressor 230 v 50/60 hz. relatively noise less fan to cool down the compressor. all steel tubes protected with special compound against rust formation. 1 thermostate pre-stetted from the factory for 2 c - 8 . control panel situated at the front of the unit. light indicators for different functions, 1 digital thermometer to indicate the internal temperature, latest cooling system. insulation with thick polyurethane foam. foaming agent- cyclo