Web Analytics Made Easy - StatCounter

Oxygen Pipeline Repair Tenders

Get complete information related to latest Oxygen Pipeline Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oxygen Pipeline Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oxygen Pipeline Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45572573 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For supplying electrical materials and repair maintenance services at. grampanchayat khalumbre tal khed dist pune - supplying and erecting modulartype switch6a / 10a, supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length, providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16-3-2), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.oh-pl/stp, supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in, supplying and erectingled street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65 ., supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65, supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95,class ip 65, providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis, labour chrages for led fitting on street light or ms light pole., dismentaling charges -led street light of pole., 1.25 mm crca sheet metal enclosures box for timmer and mcb, supplying pvc insulated pvc round sheathed 1.5 sq.mm, supplying & laying armoured cable 4c x 6 sq.mm., supplying & laying armoured cable 4c x10 sq mm, supplying & laying armoured cable 2c x 10 sq mm, supplying & laying armoured cable 4c x 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting) 5-3-3, supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5-3-7, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete, supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3, supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole., supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1-4-3, supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, 25 amp, 32 amp three phase l/t contactor, 2.5 sq. mm multistand copper wire, insulation tape, water proof tape, street light pole box frp, cement street light pole clamp, m.s. street light pole clamp, led street light arm bend pipe, small size frp box for mcb, big size frp box for mcb, supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(dwc) of hdpe for enclosing cable below ground/road surfac

State Government

CTN :44997863 Due date: 19 Jun, 202619 Jun, 2026 20.00 Lacs
Tender For bid to ras corrigendum : supply of carriage of pcc and stp poles 8.5, 11 and 13 mtr , carriage of line material , erection of pcc and stp poles 8.5, 11 and 13 mtr , erection of double poles 8.5, 11 and 13 mtr , installation and fixing of 11 kv tpmo. , erection and grouting of stay set , providing and fixing of insulator , laying of acsr weasal, rabbit and dog conductor. , erection of abc conductor , grouting of pcc and stp poles , making of plinth , fixing of earthing rod , chopping of tree branches , providing and fixing of clamps of lt , providing and fixing , carriage and installation of 25 kva transformer , carriage and installation of 63 kva transformer , carriage and installation of 100 kva transformer , carriage and installation of 400 kva transformer , dismantling of old pcc and stp poles , dismantling and removal of conductor , erection of section tee pole , carriage and installation of lt dist box , provding and fixing, filling cable joints , safe carriage of cables , laying of under ground cable , laying of overhead cable , guarding of 11 kv line by gi wire , safe carriage and installation of metering unit , safe carriage and installation of metering cubicle , provding and fixing wearing gi pipe

CTN :45576880 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For supply of m and l in repair for heat shrinkable straight through jointing kit , supply laying in repairs in trenches ducts fixing , taking out carefully cable covers and ht cable from excavated , relaying of ht cable of size 120 sqmm 3 core in trench , excavation in trenches not exceeding 1.5 mtr wide and 1.5 mtr depth , excavation in trenches not exceeding 1.5 mtr wide and depth , removing excavated materials not exceeding 50 m and depositing where directed , returning filling including spreading levelling watering and well ramming , supply and lay sand cushioning to underground ht cable complete , supply and lay reinforced precast concrete cable cover , lay only precast concrete cover size 450 230 50mm , m and l gi pipe light grade with all fittings , m and l for pcc type c2 40 mm graded stone , s and f of dgset 500 kva 3 phase with cpcb iv norms , xlpe pvc insulated cable 3.5 core 300 sqmm , m and l gi pipe light grade with all fittings complete , earthing with gi earth plate electrode 60 60cm 6 mm buried , taking out carefully existing ber dg set from ekm complex area * /bid number : gem/2026/b/7625309 + /dated: 16-06-2026 ' ' / bid document 1 / 21

CTN :45570416 Due date: 30 Jun, 202630 Jun, 2026 10.00 Lacs
Tender For the financial year 2026-27 for all types of building construction materials like cement,rebar ballast,muram,boulder etc.rates - laying and jointing pvc pipe. heading, gitti 6mm, gitti 10mm, gitti 20mm, gitti 40mm, river sand, fine sand, hard moorum, soft moorum, cement bricks, kumhar bricks, 60 mmthick paver block of m-30, cement, vetrified tiles, steel 8mm, steel 10mm, steel 12mm, steel 16mm, structural steel, galvanised steel sheet 0.63mm thick, binding wire, pvc pipe 75mm, pvc pipe 100mm, pvc pipe 150mm, pvc pipe 200mm, indian latrine sheet, western latrine sheet, wash basin, white cement, oil paint, distemper, red oxide, marbel, granite, aluminium work, garden green net, rcc hume pipe 200mm, rcc hume pipe 250mm, rcc hume pipe 300mm, rcc hume pipe 450mm, rcc hume pipe 600mm, rcc hume pipe 1000mm, g.i. fencing, angel 7 feet hight jali fetting, mason, majdoor, j.c.b., poklen

CTN :45587225 Due date: 08 Jul, 202608 Jul, 2026 9.62 Lacs
Tender For supply of supply, fabrication and construction of copper plate earthing details of electrodes and earth pit at akashvani jaspur, uttarakhand , providing of 50mm x 3mm copper strip and interconnecting earth electrodes with fabrication and fixing of 50mm x 3mm copper strip at akashvani jaspur, uttarakhand , providing and fixing of nomenclature sign marker for earth pits at akashvani jaspur, uttarakhand , providing of 25 mm x 3 mm copper strip for extension of earthing system up to the transmitter hall, ups and lt panel at akashvani jaspur, uttarakhand , copper strip laying for extension of earthing system up to the xtr hall, ups and lt panel and terminating in bus bar by digging the soil and placing the copper strip along the trenches at air jaspur , providing of 375x38x6mm copper bus bar with insulators and steel nut bolts and the fixing of 375x38x6mm copper bus bar is to be done to terminate the different earthing system at akashvani jaspur , making of trenches of size 700mm x 750mm for 185 sq mm 3.5 core starting from state electricity transformer to lt panel by digging the soil which includes cement concrete interlocking tiles , providing and grouting of 2 nos. of 4inch dia g.i. pipes of different length on the cement concrete flooring, road, and cement concrete interlocking tiles and along the vertical walls. , unwinding roll of 185 sq. mm 3.5core al. cable from their cable drum and laying the cable through the trenches and through the g.i. pipes as laid down at akashvani jaspur , reconstructing the cement concrete interlocking tiles floor and repairing the area with cement concrete interlocking tiles and finishing the surface at akashvani jaspur , providing and fixing of lt cable route marker made up of 2.5inch dia signage with 10mm x 2ft long ms rod from transformer to lt panel at akashvani jaspur , providing and fabricating of overhead shed for the installed 62.5kva dg set as per drawing at akashvani jaspur supply, fabrication and construction of copper plate earthing details of electrodes & earth pit as per given below: digging of pit of size: 1 mtr x 1 mtr x 3.5 mtr(d) providing of copper plate size 600 x 600 x 3mm. providing of copper strip of 50x3mm shall be extended from bottom of the earth pit to the surface of the earth pit, after joining the copper strip by copper rivets and proper brazing of strip to the copper plate. providing and fixing the 10ft. long 38 mm dia class c g.i pipe of reputed make such as surya, jindal or similar and fixing with the copper plate in the center with g.i/ ss nut bolts class c. one g.i. reducer at the top of the pipe is to be provided for fixing steel mesh for watering as shown in the drawing. placing the copper plate with pipe and strip into the pit. providing & filling of 2 nos. of bags of bentonite each of 50 kg. (for each earth pit.) providing & filling of 80kg charcoal, and 80kg raw salt in alternate 3 to 4 layers in each earth pit. the fresh soil about 2.0 cubic metre in earth pit size in layers is to be arrange to fill the pit for proper result. proper watering of the filled pit for initial charging of pits. providing of heavy duty c.i. cover with lifting hooks. construction of cc chamber in ratio 1:4:8 & fixing of heavy duty c.i. cover., providing of 50mm x 3mm copper strip and interconnecting earth electrodes with fabrication & fixing of 50mm x 3mm copper strip as per given below: i. 2 grid out of 6 pits for transmitter. ii. 1 grid out of 3 pits for audio. iii. power supply-3 pits separate (lt electrical panel, ups & isolation transformer, avr) iv. rf //bid details 2 / 25

CTN :45585816 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For restoration of rain damages wss koharchhan in tehsil amb distt. una (hp) (sh:-excavation, laying, jointing & testing of damaged gi pipe 50 mm dia)

CTN :45533036 Due date: 20 Jun, 202620 Jun, 2026 7.99 Lacs
Tender For one panchayath one playground- development of ezhikkara grama panchayath ground in paravur lac, ernakulam district- supply and installation of open gym equipment - retender - inauguration stone and interlock laying for open gym area, od34726/2026-2027 providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre polished, machine cut for inauguration granite stone of required size, approved shade, colour and texture laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) joint treated with white cement, mixed with matching pigment, epoxy touchups including rubbing, curing etc. complete at all levels. area of slab over 0.50 sqm, 16.21 engraving letters in hard stone, od419846/2025-2026 providing and laying of interlock concrete block pavements having thickness 60mm (m35) as per drawings and technical specification clause 1504 confirming to is 15658 and laid in required colour and pattern over and including 50mm thick compacted bed of 6 mm metal including edge concreting for 300mm width and 150mm depth with cc m35( @ 0.045 m3/m), supply and installation of open gym equipment, od27550/2026-2027 chest press (double) - supply and installation of double chest press having the following specifications: dimensions: (l x w x h) 1955 x 710 x 1900 mm. main center pipe - ø 114 mm od ?b? class gi pipe. foundation plate ?m.s. round plate of ø 250mm & 8 mm thick. foundations cover cap- dome shape of pp / nylon / hdpe material. remaining frame - made up of ø 48 mm od ?b? class g.i. pipe. handle - made up of ø48mm od ?b? class g.i. pipe. link - made up of ø 48 mm od ?b? class g.i. pipe. seat & back rest ? 380 x 275 x 60 mm thick high-density polyethylene (hdpe) blow molded with m10 integrated wall thickness 3 to 4 mm. bearing bush closing cap?s? pp / nylon / hdpe material. handle must be connected with frame by 8 mm laser cutting ms profile. top closing cap ? dome shape made by pp / nylon / hdpe material. foundation stool: made from main pipe ø 88 mm od m.s pipe and top support of m.s. round plate of ø 250 mm & 8 mm thickness is welded top. square tube of 30 x 30 x 2 mm must be used to support center pipe. height of stool is 3 ft. foundation stool is embedded in c.c. stock below ground level. bearing - use is 6005 permanent lubricated reputed brands. pin ? made up of ø 25 mm m.s. bright bar pin. bearing bushes - ø 60 mm od seamless pipe. grips - high quality rubber ø 46 mm od. circlips?a 24 circlips are used for assembly. coating - best quality of powder coating 80-120 micron. safety instructions and exercise chart - start & finish position stick on product. all joints must be welded as per is standards and zinc primer paint should be applied at all the welding points prior to finishing. (foundation shall be m20 cc and design shall be approved by the engineer-in -charge before installation.), od30940/2026-2027 surfboard - dimensions: (l x w x h) 1090 x 890 x 1390 mm. main frame made from two pipes of ø 114 mm od b class gi pipe. foundation plate m.s. round plate of ø 250 mm & 8 mm thick. connecting pipe - ø 88 mm od b class gi pipe is used to connect both main frame pipes at top end and ø 42 mm pipe is used to connect at bottom end. handle - ø 42 mm and ø 33 mm od b class gi pipe. support pipe ø 60 mm must be used to support leg movement frame. leg movement frame ø 42mm od b class gi pipe. footrest - cast iron 325 x 270 x 8 mm thick and m.s. plate of 250 x 200 x 2 mm thick use for to support it. bracket - 8mm thick laser profile is used to support leg movement frame. top closing cap dome shape made by pp / nylon / hdpe material. closing caps pp / nylon / hdpe material. foundation stool: made from main pipe ø 88 mm od m.s pipe and top support of m.s. round plate of ø 250 mm & 8 mm thickness is welded at top. square tube of 30 x 30 x 2 mm must be used to support center pipe. height of stool is 3 ft. foundation stool is embedded in c.c. stock below ground level. grips - high quality

CTN :45542106 Due date: 22 Jun, 202622 Jun, 2026 1.33 Lacs
Tender For providing fixing and installation of fire material for fire station mc patiala. est cost rs. 1.33 lacs dt 22/23.06.2026 - xlpeinsulatedarmouredcables (loose):supply, laying and erection of aluminium conductor xlpe insulated pvc sheathed armoured and served cable 1100 voltsgradeasper is7098 (part-1)1988 tobe laid loose intheexistingtrenchorpipeas per pwd general specifications overall size 35sq.mm (4core) armoured(loose), mccbs (for panels & sheetenclosure):supply and erection of moulded case circuit breaker (panel mounting cubical type) in the existing cubical panel (confirm to iec:60947-2) having ics=100% icu, 100% neutral with spreader terminal links,extendedrotary handle and relevant pwd general specificationscompletewithg.i. bolts, nuts &connection on both sides of mccb with suitable size of thimbles etc:mccbfourpole200amp.,415volts, 25ka fixed magnetic and adjustable thermal setting, sheet metal bus barchambers (copper strips):supply and erection of sheet metal bus bar chamber (factory fabricated) duly powder coated on existing surface with required 4 nos.of tin plated copper bus bar strips of suitable length and cross sectional area mounted on dmc/ smc mouldsat sufficient distance, enclosure made of m.s. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmiumplated iron screws and of given overall dimensions and to be fixed with g.i.bolts and nuts/ ragbolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the engineer-in-charge at site:bus bar chamber 200amp., 415volts overall dimensions (455mm x 455mm x 150mm) nominal, supply and erection of heavy duty aluminium thimbles/lugs for cable endtermination duly crimped including making necessary connectionscompletely aluminium thimble cable core size 2535sq.mm, earthing with g.i.wire/ rope ing.i.pipe partly recessed and partly on surfacecomplete with 150 cm long 50mm dia.g.i. earthpipe (cutting threads and 36 nos. holes, 1cmdia. to makeamesh around the gi pipe) withg.i. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with20kg. charcoal & salt mixture etc., upto 8 metre in length (including boring & refilling). earthing with 8 s.w.g. (4mmdia.)g.i.wirein 15mm dia g.i. pipe with g.i. reducing socket 50mm x 15mm (upto 8metre in length), supply of mccb enclosure in all respects make lk/havells, supply of clump 1" g i, supply of screw 1.5"with gutty

Corporations And Associations And Others

CTN :45523190 Due date: 19 Jun, 202619 Jun, 2026 4.76 Lacs
Tender For provision of new led street lights with allied accessories on existing poles at various dark spots in saidulajab ward no 160 under south zone - led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy >135 lm/watt). supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, frequency 50/60 hz, operating temp range -5 0c to 50 0c, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%,thd 10% as per iec 61000-3-2, p. f. 0.95, ip-66,ik-10, cri >70, under voltage and over voltage protection, emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitary) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation color matching)5, maximum power consumption should not more than the specified rating and fixture shallbe of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductorsingle core cable and earthing etc. as required withminimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 testreport and all testing required for led fixturesas per bis shall be submitted.. shape size and cct shall be as approved by engineer-in-charge asper requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). 45 watt , supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm

Corporations And Associations And Others

CTN :45523194 Due date: 19 Jun, 202619 Jun, 2026 4.67 Lacs
Tender For provision of led light fittings with accessories at various locations in ward no. 167 khanpur, under south zone. - supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm, led street light fixture, powder coated pressure die cast aluminum body (system lumen efficacy 135 lm/watt) supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -5 deg centigrade to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-45, driver efficiency >85%,thd 10% as per iec 61000-3-2 , p. f. 0.95, ip66,ik-10, cri 70 , under voltage and over voltage protection,emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c). 45 watt
 Loading, Please wait...

Connect us via What's Up