Get complete information related to latest Pacemaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pacemaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pacemaker Tenders.
Tender For corrigendum : supply of inlet lcf pre filter for pall make oil purifier ,model no- hnp075r3zcpenb, partno-hca082eos8z , inlet filter seal kit for pall make oil purifier, model no-hnp075r3zcpenb - part no. ur319skz , sentry final filter 12 micron for pall make oil sentry modelno-xpft55cpznbsp8300, partno- ue610as40z , outlet filter element 5 micron- part no. ue610ap40z , outlet filter element 25 micron for pall make oil purifier, model no-hnp075r3zcpenb,part no- ue610at40z , oil mist filter element. make- pall, part no- pfs1001zmh, for oil purification unit. , hnp075vacuum pump1 year service kit along with vacuum pump oil. pall partno-cg00517 plus hs82002. , vacuum pump coalescer element for pall make oil purifier, modelno- hnp075r3zcpenb, part no-cg00516 , outlet dp indicator- part no. rc861cz090zyt , fluid pump kit- part no. cg01778 , kit valve bypass- part no. cg01019 , air filter block indicator of pall make hnp022 oil purification machine, part no- hc0293d004 , 415v 50hz u5.70 motor- part no. cg02814 , fluid pump service kit- part no. cg01664 , vacuum gage for pall make oil purifier model no- hnp022r3zcpenbx167, partno-hs80115 , float switch assembly for pall make oil purifier, model no- hnp075r3zcpenb,part no-cg01668 , inlet lcf- part no. hc9600eos8z , outlet filter element 12 micron- part no. ue310as20z , outlet filter element 5 micron- part no. ue310ap20z , oil mist filter element of pall make hnp022 purification machine,fl04, part no-cg00791. , vaccum pump coalescer element , part no - hs80482 , make - pall , for oil purifier , vacuum pump service kit -1 year- part no. hs80492 , vaccum pump lubricating oil, part no- hs82002, make - pall, for fryquel oil purifier , fluid pump- part no. cg01012 , inlet relief valve- part no. cg01019 , vacuum pump- part no. cg01034 , fluid pump service kit of pall make hnp022 oil purification machine, part no-cg01025 , auxiliry conduct- part no. cg00888 , relay 01 02 for pall make oil purifier,model no- hnp022r3zcpenbx167, partno-cg01016 , vacuum vessel gasket for ms. pall make vacuum dehydration machine,model-hnp022,part number-hs72039 , filter seal kit- part no. h8304skz , vessel gasket- part no. cc40300 , inlet starainer- part no. hs76463 , check valve- part no. hs75018 , sentry pre filter 22 micron for pall make oil sentry, model no-xpft55cpznbsp8300,part no-hc8300fct16z , pre filter 25 micron- part no. hcy8300eoj16z , motorised ball valve -recirculation valve - part no. skr14456 , motor pump set oil transfer pump - part no. hs76459 , mechanical seal- part no. cg11001
Tender For procurement of medical consumables items for use by the cardiology department, goa medical college, bambolim - injectable cardiovascular ultrasound contrast agent comprised of lipid-coated echogenic microbubbles filled with octafluoropropane gas or equivalent approved agent (cost comparison will be based on per study cost); in remarks - please detail the dose required per study per the instructions for use, disposable electrodes designed specifically for patient monitoring, disposible electrodes designed specifically for stress testing - please quote only those that are specifically designed for stress testing, disposible electrodes designed specifically for holter monitoring - please quote only those that are specifically designed for holter monitoring, disposable defibrillator patches (anterior and posterior) for use with philips brand defibrillators, disposable radiolucent defibrillator patches (anterior and posterior) for use with philips defibrillators, printer paper roll for philips mrx defibrillator and for efficia defibrillators, thermal printing paper for sony thermal printer used with echocardiography machines (model up/d-897), ultrasound jelly for echocardiography 5 litre pack, ecg thermal printing paper for use with philips pagewriter tc20 ecg machine; philips make only, ecg thermal printing paper for use with ge mac 5500 hd ecg/stress testing machine; ge make only, ecg thermal printing paper for use with bpl cardiart 6208 view plus ecg machine; 80 mm width roll, filter for hamilton ventilator hma anti-bacterial filter, flow sensor for hamilton g5 ventilator, oxygen cell for hamilton g5 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, abg machine sensor cassette for radiometer abl 9 machine - 200 tests with 60 days validity with ph, pco2, po2, hct, na, k, ca++, chloride, lactate, abg machine ssolution pack for radiometer abl 9 machine (sp9), ventilator circuits (two limb) for adult patients, non-invasive ventilator face mask, nasal prongs for pediatric patients, normal saline 1 l pouch pack suitable for use with pressure infusor bag, normal saline 0.5 l pouch pack suitable for use with pressure infusor bag, pressure bag with manometer for iv infusion/pressure infusor bag, silk suture sterilized and packed with cutting needle 1.0 silk nw 5062 or equivalent, silk suture sterilized and packed with round body needle 1.0 silk nw 5063 or equivalent, surgical skin stapler with stapler cartridge for pacemaker pocket closure, staple remover, surgical disposible scalpel blade only number 11, surgical disposible scalpel blade only number 15, iodine impregnated antimicrobial transparent incise drape 23 x 23 cm, film transparent dressing with non-adherent pad 3 1/2 inches x 6 inches (9 x 15 cm), packing material for cath lab use 5 cm width x 200 metres roll, packing material for cath lab use 7.5 cm width x 200 metres roll, packing material for cath lab use 10 cm width x 200 metres roll, packing material for cath lab use 15 cm width x 200 metres roll, packing material for cath lab use 20 cm width x 200 metres roll, packing material for cath lab use 25 cm width x 200 metres roll, packing material for cath lab use 30 cm width x 200 metres roll, ethylene oxide (eto) gas cartridge, labelling instrument for packed items for cath lab, printer ribbon for use in labelling instrument l-1 will be calculated for labelling instrument with label rolls (total quantities), label roll for use with instrument quoted for in labelling instrument with built in eto exposure indicator, label roll for use with instrument quoted for in labelling instrument with built in steam exposure indicator, biological indicator for use in eto sterilizer, biological indicator for use with autoclave sterilizer, incubator for use with biological indicators quoted above l-1 will be calculated for incubator with total quantities of biological indicators in above two rows, steri
Tender For tender for the supply of cathlab consumables to wenlock district hospital mangalore - permanent pacemaker vvir single chamber, permanent pacemaker dddr double chamber , permanent pacemaker aicd single coil , renal stent all sizes , carotid stent all sizes , peripheral stent all sizes, pda devices all sizes , asd dvice all sizes, drug electing balloon all sizes
Tender For supply of lead of pacemaker (endocardial) with pli. endocardial electrode -tined, steroid electrode with unipolar/bipolar modes and compatible with 7f p f24. it should have 1s-1 connector, compatible for all pacemakers,[ai(2025-26) , item code no.s-62243, sl no.2018] ]
Tender For supply of lead of pacemaker screw in ( endocardial / epicardial ) with pli - screw in steroid clotting or coated electrode unipolar or bipolar modes and compatible with 7f pli .it should have 1s-1 connector, compatible for all pacemakers.[ai(2025-26) , item code no.s-62244, sl no.2019] ]
Tender For corrigendum : supply of 3 tesla mri compatible single chamber (ssir ) pacemaker with matching electrode (58 cms), pli and magnet & fluro-cover. 3 tesla mri conditional with full body scan. compatible with tined/screw-in lead. pacing mode: vvi, vvt, voo, aai, aat, aoo, ooo. pulse amplitude should be up to 7.5 v at least. auto capture or capture management algorithms. sensing assurance is an essential feature. weight around 20 gm and volume 10 cc. expected longevity to be not less than 12 yrs at 100% pacing of 2.5v, 0.4 mv, impedence 500 & electrode should be steroid electrode or coated electrode/unipolar or bipolar, tined or screwd compatible through 7f pli. the oem must have registered office with service personnel available round-the-clock. warranty: all pacemakers should be covered by life time warranty (providing pacing therapy for the duration of patient's life time).[ai(2026-27), item code-no: s-62239, sl no.2141] ]