Get complete information related to latest Paint Booth Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Paint Booth Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Paint Booth Tenders.
Tender For repair /replacement of perimeter light securiy light garden light solar light area light pole painting and all connected e/m item at nms under age (i) nabagram
Tender For providing of custom bid for services - annual maintenance contract & support services for thermal protection system (tps) and painting booths at aerospace division hal (bc)
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For sic of submersible pump set and all allied e/m equipment for rebored tube well near h.no.-116c shahpur jat in greater kailash constituency ac-50. - supply of submersible pump set fitted with dynamically balanced ss impeller mounted on stainless steel shaft with protection sleeve having stage bowl & closed grained shorted type impeller, the pump will be directly coupled to required wet type induction motor of 7.5 hp, 10 stage, speed 2900 rpm suitable for operation of 3 phase, 415 volt, 50 hz, ac supply with efficiency 70% at following duty point:200 lpm on 90 mtr. head. having discharge outlet 50 mm and outside dia 142 mm.make: bs/skope/ any djb approved make, supply of hut type electrical feeder pillar / fabricated with 50 x 50 x 6mm angle iron and 16 swg ms sheet with horizontal and vertical intermediate member of suitable size. i.e. 1370 mm x 760mm x 460 mm. with arrangement for mounting of switchgear and electrical energy meter i.c. painting heaving following item fitted.a) mccb 63 amp, 4pole, 415volt, 35 ka -1 no.b) rccb 63 amp, 4pole with earth fault indication protecting a circuit automatically in the event of earth leakage sensitivity 100ma, - 1 noc) fully automatic star delta starter of relay range 13-21 amp. (7.5 hp to 10 hp) 3 phase oil immersed type -1 no.d) ampere 96 x 96 mm. square shape 0-30 amp-1 no.e) voltmeter 96 x 96 mm. square shape 0-500 volt-1 no.e) indicating lamp (a set of 3 lamps) 1.setf) shunt capacitor of 10 kvar mpp type with three phase isolator with suitable bankingg) motor protection assembly with earth leakage protection phase sequence corrector, single phasing, protection, overload protection, high voltage / low voltage protection time delay power on, programmable time switch i.c. r&b phase facility to change over from automatic, to manual &vice verse for up to 10 h.p -01 nos. complete wiring & installation of above accessories with required copper conductor wire and thimble etc. 01 job.make of all components: any djb approved., s/o pvc insulated & pvc sheathed cable with plain copper conductor having 3 phases, 3 core flat for submersible motor of 4 square mm size each 100 mtrs.make:grandlay / havells./any djb approved make, s/o m.s. clamp of 600 mm length duly fabricated out of 12.5 mm thick 75 mm wide, m.s. plate for holding the pipe of 50 mm dia., s/o double flange gi column pipe 50 mm dia medium class each of 3 mtrs long duly threaded on both ends, welded fitted with gi flange on both ends with slot of submersible cable. make: tata/ jindal./any djb approved make, s/o/ tail piece of the medium class gi pipe 500 mm long with one end threaded as per outlet of pump & another end flanged as per size of gi pipe 50 mm dia., s/o gi 90 bend of size 50 mm dia having both side flange (heavy duty)., s/o nut & bolts of 1/2 dia of different size i.e. 1.5 dia& 2.5 long full threaded., s/o rubber packing for 50 mm dia flange., fabrication and supply supply of bore cover approx size 8-10 inch diameter made out from 6mm thick m.s. sheet in 2 halves & a circular hole in centre 3-1/2 dia. with locking arrangement by nuts & bolt., earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., installation of t/well by lowering of sub p/set with all allied above items. this includes installation and grouting of panel boards with all electrical wiring & cabling at site. all tools & tackles i/c. tripod chain pulley blocks etc. shall be arranged by the firm. this includes testing & commissioning of t/well on load at site i/c. cartage, loading & unloading of material. it also includes a trial run of 30 hrs operation successfully by the firm. all required civil work included in the scope of work.
Tender For providing of professional painting service - cemented item; painting of optical fiber cable route markers and manhole chambers as per scope of work; as per scope of work
Tender For tender for supply of operation and comprehensive maintenance of ems at kadma te build jsr d d - as per item no-1 of sh-i sor in sec-3 part c of atc , replacement 100amps 4 pole isolator , replacement 63amps 4 pole mcb , replacement 32amps 3 pole mcb , replacement 40-63amps dp mcb , replacement 6-32a spmcb , replacement 100 amps 415v hrc fuse links- din type , replacement 125 amps 415v hrc fuse links- din type , replacement 63 amps 415v porcelain fuse unit , supplying and drawing 3x1.5sqmm wireing , supplying and drawing 2x1.5sqmm , supplying and drawing 3x4.0sqmm , sf pvc junction box along with 150 amp 4 way connectors , suppllying xlpe 1.1 kv al 4x10 sqmm cable , suppllying xlpe 1.1 kv al 2x6 sqmm cable , laying of xlpe cable in ground , laying of xlpe cable on wall surface , laying of cable existing rcc/ hume/ metal pipe , sh 40 mm dia g.i pipe medium class ias per nit. , sm end term with brass gland and alum lugs 4 x 10 sq. mm , sm end term with brass gland and alumi lugs 2 x 6 sq. mm , repl. 63 amps 415 volts tpn sdfu with hrc fuses , repl. 125 amps 415 volts tpn sdfu with din type hrc fuses , repl. 250amps 415 volts tpn sdfu with din type hrc fuses , repl. 400a fp mccb , 36ka overload rel , repl 63 amps 415 volts tpn sdfu in sheet , s/f 36 /40-watt fluorescent tube rods , s/f starter for fl. fittings , s/f 9 /10-watt led lamp (b22) , s/f 12/15-watt led lamp (b22/e27) , s/f 20/22w ultra bright led retrofit tube light , s/f 24w led battype with very high eff 115 lm/w , replacement angle/batten holder , replacement 36/40 w fl tube light holder , replacement 36/40 w fl tube light starter , replacement ceiling rose , replacement 5/6amps 250 volts 3 pin plug top , 15/16amps 250 volts 3 pin plug top , replacement 6 /10 amps 1 way piano type switch , replacement 16 amps 1 way piano type switch , replacement 6 amps 3 pin type socket , replacement 16 amps 3 pin type socket , rewinding of 1200mm/1400mm ceiling fan etc. as required. , repl stepped type electronic fan regulator (switch type) , rep 2.25 mfd 440 volts capacitor for ceiling fan , bearings for ceiling fans etc. as required (make skf/ss) , rewinding 380mm 1500 rpm 230 v heavy duty exhaust fans , supply and replacement of 45 watt street light , supply and replacement of 27 watt street light , dehyd filt & testing of existing trasformer , supplying of new transformer oil , replacement gasket of transformer , replacement lt side stud bush , painting of transformer with good quality synthetic paint , s/f diesel filter with o ring (primary) 160kva d e/a set , s/f lub oil filter with o ring 160kva d e/a set , s/f diesel filter with o ring (secondary) 160kva d e/a set , s/f engine oil(mobil) 160kva d e/a set , sevicing by authorised dealer /oem for160kva dg set