Web Analytics Made Easy - StatCounter

Painted Glass Tenders

Get complete information related to latest Painted Glass Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Painted Glass Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Painted Glass Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45628776 Due date: 22 Jun, 202622 Jun, 2026 42.78 Lacs
Tender For annual repair and maintenance of to goi press colony gpra qtrs at mayapuri new delhi during 2026-27 sh-supply of painting material for external finishing- anti-termite pesticides -(imidacloprid) , cement opc/ppc, , cement - white, , admixture for concrete, , reinforcement steel (thermo-mechanically treated bars (fe 550 d), , alccofine, , mechanical couplers for reinforcement, , ready mix cement concrete, , architecture expansion/seismic joint system, , expansion filler board premoulded compressible (non bituminous), , concrete curing compound, , core cutting, , expanded polystyrene sheet (eps), , soil anchor for diaphragm wall, , pvc water stop, , ready mix polymer jointing cement mortar, , glass brick/glass block, , all type of door lock, floor spring, door closer including mortice locks, , customised door window hardware /joinery fittings, , flush door shutter, , aluminium, , façade and window system, , fire stop in curtain wall system, , pop out vent for façade and system window hardware, , aluminium glass partition system, , aluminium openable louver, , air transfer grill, , fire rated glazed door, , metal fire rated doors, , wooden fire rated doors, , fire rated hardware & system, , fire seal, fire smoke seal, , fire rated glass, , fire rated rolling shutter, , fire curtain, , glass shower partition, , modular toilet cubical, , laminates, , compact laminate sheet, , polysulphide sealant/pu sealant, , glass & mirror, tinted glass,, , high performance glass, reflective glass, lacquered/back painted glass all superior quality, , silicone sealant, , polyester powder coating/pvdf coating, , wired glass, figured/pattern glass, , acoustic seal / door seal, , pvb/sgp laminate film, sentry film, , wood adhesive, , frosted film, , bmu/ façade cleaning system, , dry stone cladding undercut anchor, , stone sealer, , water & stain repellant coating for stone cladding and stone flooring, , gypsum lightweight plaster, , ready mix cement plaster, , crystalline integral, , waterproofing, , water proofing compound, , water proofing membrane (pvc/hdpe)/water, , proofing coating (pu/polyurea/ acrylic/elastomeric cementitious) / sri coating/pitch pu, , water stops - hydrophilic swellable rubber strip (non bentonite type), , polyurethane over deck insulation foam, , food grade epoxy coating for water tank, , vitrified tiles, , tiles/stone fixing adhesive/epoxy grout, , polyurethane concrete flooring, epoxy flooring, self leveling flooring, , wooden flooring and skirting, , raised/false access flooring system, , solid surface (corian), , car deck flooring system, , engineered marble, , rubberized sports flooring (gym flooring), , stainless steel, , structure steel & hollow section-primary producers only, , , , , , access panel in false ceiling system, acoustic panel, aluminium/metal ceilings (baffle and open cell ceiling), aluminum panels, anchor fastener, rebar, chemical/mechanical fastener, expandable fasteners, b, bonded particle board, cement fiber board/ cement, d, dry wall gypsum partition/paneling system for toilet, gypsum wall paneling, , , , , , , grg/gi suspended ceiling grid system & close/ c stud framing system, gypsum ceiling system (plain/perforated),, i c, non shrink cementious precision (anchoring) grout, paint - acrylic emulsion (exterior), paint - anti carbonation paint, paint - plastic emulsion (internal), paint - pu & epoxy paint and primer, paint - synthetic enamel, paint texture paints (interior), plywood (all plywood shall be procured from fully owned factory of the manufacturer and not from jv / outsourced), pu polish for wood work, rock wool/glass wool insulation, , , , , , ss modular railing system, steel (ms) rolled section & plate, steel hollow sections, t, tile trim/threshold, veneer, white cement based putty, soft board, , polycarbonate sheet/skylight, , c, , galvanized/galvalume roofing sheet and accessories d, , pre cast concrete landscape elements, gratings, kerb, drain cover, , preca

CTN :45322644 Due date: 01 Jun, 202601 Jun, 2026 8.70 Lacs
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh

CTN :45261653 Due date: 04 Jun, 202604 Jun, 2026 35.0 Thousand
Tender For supply of combination plier 8inch tapariya make , screw driver star plain 12inch tapariya make , pt bulb 100 watt 240v surya make , cotton tape1inchx20meter , glass tape 1inchx50meter , dr back insulting varnish lufta each pack 1ltr , steelgrip self adhesive pvc electrical insulation tape , pt bulb 100 watt 24v , dr back bectrol red each 1 ltr pack , air heater u type 2kw fins type , glass sleeve 10mm , glass sleeve 12mm , crc , glass sleeve 6mm , glass sleeve 2.5mm , empire tape , pt holder 5amp
 Loading, Please wait...

Connect us via What's Up