Get complete information related to latest Panel Assembly Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Panel Assembly Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Panel Assembly Tenders.
Tender For impregnation / repair / rewinding of 25 hp motor alongwith allied works at malhar intake stage-0, repair to 50 ampere lt control panel alongwith allied works at malhar intake stage-0, repair to 100 kva voltage stabilizer alongwith allied works at ma
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con
Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be
Tender For shifting, installation, testing and commissioning of 3000gphx200 head meter hc pumpset alongwith allied works and design, fabrication, providing, installation, testing and commissioning of 70 ampere lt control panel alongwith allied works at pumping
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For supply and retro-fitment of set of attachment panels with fire extinguisher attachment / washbasin attachment / inside dustbin assembly in lhb coaches. 1) retro fitment of fire extinguisher panelassembly with dustbin mount confirming to icf drawing no. icf/sk3-32963403, alt. nil, qty. 2 nos. /set. 2) retro fitment of wash basin panelassembly with dustbin mount confirming to icf drawing no. icf/sk3-32963415, alt. nil, qty. 2 nos. /set. 3) retro fitment of inside dustbin fixing arrangement (lhb coaches) confirming to icf drawing no. icf/sk3-32963414, alt. nil, qty. 4 nos. /set. (note: the warranty period shall be 6 years from the date of installation/fitment.) [ warranty period: 72 months after the date of delivery ] ]