Web Analytics Made Easy - StatCounter

Panther Conductor Tenders

Get complete information related to latest Panther Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Panther Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Panther Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45316007 Due date: 09 Jun, 202609 Jun, 2026 1.83 Crore
Tender For replacement of 33 kv acsr panther conductor by 33 kv acs al-59, 232.5 sqmm. covered conductor of 33 kv line from tapobhumi to chalang under edsd, it park under edd, raipur

State Government

CTN :45289480 Due date: 30 May, 202630 May, 2026 NA
Tender For renovation of electro mechanical items for rural ws scheme, lesliganj - part a (raw water p/plant mali river at sitadih ), cost towards repairing and overhauling of 50 h.p. v.t. pump set multiple stage ball assembly s/f impeller g.m. bush as per sample 5 nos each, s/f housing bush as per sample. replace in spider rubber cutless bush 5 nos, replacing of 25mm dia. 5 feet long s.s. line shaft 4 nos with s.s. socket . transportation charge from site to work shop vice versa including tools tackles and labour charges for lifting & lowering v.t. pump before and after repairing work etc all complete at pumping plant., supplying all labour tools and tackles for complete opening, dismantling , cleaning of its slots of stator by brush & petrol then complete rewinding of 50 h.p. 440 volts, 50 c/s, star delta, 3 phase hollow shaft v.t. motor by supplying super enameled copper wire & binding, tapping varnishing, heating, testing on full load and repairing of stator & rotor, changing of bearings as per sample skf make with including the deduction of cost of burnt copper wires and transportation charges from p/plant to workshop and back to the same . including tools & tackles and labour charges etc all complete at p/plant., cost towards repairing/ replacement of 200 amp motor control panel board consisting of incoming feeder mccb 200 amp 1 no. and outgoing feeder mccb 100 amp 2 nos, timer 1 no., thermal over load release relay 2 nos. supplying and fitting of digital volt meter (0-500v) squared type 2 nos, ammeter (0-125amp) squared type 2 nos and replacement of phase indicator lamp 3 nos. including internal wiring etc all complete., cost towards supplying & fitting 35 mm2 3 core copper conductor 15 mtr panel to motor., cost towards supplying & fitting 60 watt led street light (jsor-m840), part b (clear water lesliganj.), cost towards repairing/ replacement of 200 amp motor control panel board consisting of incoming feeder mccb 200 amp 1 no. and outgoing feeder mccb 100 amp 3 nos, timer 1 no., thermal over load release relay 3 nos. supplying and fitting of digital volt meter (0-500v) squared type 2 nos, ammeter (0-125amp) squared type 2 nos and replacement of phase indicator lamp 3 nos. including internal wiring etc all complete., supplying all labour tools and tackles for complete opening, dismantling , cleaning of its slots of stator by brush & petrol then complete rewinding of 20 h.p. 440 volts, 50 c/s, star delta, 3 phase induction motor by supplying super enameled copper wire & then tapping varnishing, heating & testing on full load and repairing of stator & rotor, changing of bearings as per sample skf make with including the deduction of cost of burnt copper wires and transportation charges from p/plant to workshop and back to the same . including tools & tackles and labour charges etc all complete at p/plant., cost for repairing of 20 h.p. c/f pump with m/s/f s.s. shaft as per sample 1 no. c.i. gland tightner 2 nos, c.i. bearing housing 2 nos, ms. check nut 2 nos, c.i. neckring 2 nos, ball bearing s.k.f. as per sample 2 nos, all labour tools & tackles and materials with loading and unloading transporting charge from site to workshop & vice versa., cost towards varnishing, heating of winding & greasing of both side ball bearing of 25 h.p. induction motor 3 phase, 1440 rpm, volt 410 10% 50 cycle along with supplying & fitting of tyre coupling 2 nos, then testing on full load at site including supply of all labour tools and tackles., cost for repairing of 25 h.p. c/f pump with m/s/f s.s. shaft as per sample 1 no. c.i. gland tightner 2 nos, c.i. bearing housing 2 nos, ms. check nut 2 nos, c.i. neckring 2 nos, ball bearing s.k.f. as per sample 2 nos, all labour tools & tackles and materials with loading and unloading transporting charge from site to workshop & vice versa., supplying all labour tools and tackles for complete opening, dismantling , cleaning of its slots o

corporations/Associations/Others

CTN :45294905 Due date: 03 Jun, 202603 Jun, 2026 2.97 Lacs
Tender For supply and installation of various electrical equipments in place of burn out and damaged ones at different panels and allied works at shanagar burning ghat. - supply and delivery of mccbs with thermal magnetic release breaking capacity thermal release rang 125-160a, breaking capacity icu at 415v ac, 50hz, 50ka4pole , supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range: 24-40, mn2, , power contactors: supply and fixing the power contactor t.p 70a, l & t make (ml-4) having 240v, 50hz, coil incl. 2 no + 2 nc aux contact block., , power contactors: supply and fixing the power contactor t.p 16a, l & t make having 240v, 50hz, coil incl. 1no+1nc aux contact block., , supply & fixing of 415/440 volt, hrc fuse (make: l&t/havels/cgl/ge).for 250 amp supply and fixing of analog ammeter ranging 0-100amps having c.r ratio of 100/5a, 144 mm sq size (make: ae/kappa/mp)., , supply and fixing of analog voltmeter ranging from 0-500 v of 144 mm sq size (make: αε/καрралмр)., , supplying and fixing 415v, tpn sfu open execution in existing ss enclosure/cubical with nuts bolts etc incl. s & f 3 nos. din type hrc fuse as per rating. 125a siemens, , supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection legrand 63 a fp, , supplying of 1.1 kv. grade pvc insulated conductor of following cables (make: polycab/gloster/havells/):size in sq. mm, no & dia. of wire in mm, no of core - 4 1/2.24 3, , annexure - i basic rate of materials: (all rates of materials from k-1 to k-14 are excluding vat) 70.1.5 sq.mm 'fr' stranded copper wire, , compression glands.supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture(proof entry of xlpe/pvc armoured cables as below: for, , 3 core.(i)upto 4 sqmm, , finishing cable ends.(b)finishing the end of following xlpe/pvc, , armoured cables by crimping method incl. supplying and fixing solderless socket (dowels make), tapes, anticorrosive paste & jointing materials. (ii) 2 core 6 sqmm cable, , temperature controller: a) supply and fixing the digital type temperature controller of range (0-1200) deg. c of overall dimension 92 sq mm dia x 105mm depth having (cr-a1) heat sensor and 1 no + 1 n.c change over contact to be actuated at crossed of desired temperature in deg.c complete power supply unit of 230v 50 hz., , blue max make

State Government

CTN :44910846 Due date: 30 May, 202630 May, 2026 1.81 Lacs
Tender For corrigendum : etender for replacement of old double zebra conductor to new double zebra conductor of 33kv incoming side replacement of old single panther conductor to new single zebra conductor of 132kv side of 40 63 mva x-mer at barwaha 220kv

State Government

CTN :44911105 Due date: 30 May, 202630 May, 2026 NA
Tender For corrigendum : for replacement of old double zebra conductor to new double zebra conductor of 33kv incoming side of 40 mva & 63 mva transformer and replacement of old single panther conductor to new single zebra conductor of 132kv side of 40 mva & 63 mva transformer and dismantling and erection of 220kv bus section isolator with associated works at 220kv s/s barwaha under t. dn. barwaha.

State Government

CTN :45291512 Due date: 06 Jun, 202606 Jun, 2026 NA
Tender For tender for supply of supply of hardware fittings and conductor accessories -33kv isolator jaw made of copper (m/s rama make isolator) having 1250 amp. , supply of 33kv isolator jaw made of copper (m/s rama make isolator) having 2000 amp. , supply of 33kv ct bi-metalic terminal connector duly made of lm-6 alluminium alloy. twin acsr panther conductor , supply of 33kv cb bi-metalic terminal connector duly made of lm-6 alluminium alloy. twin acsr panther conductor. , supply of lm -6 all-alloy 33kv ct clamp threaded type suitable for twin panther conductor. , supply of lm -6 all-alloy 132kv ct clamp pipe type suitable for twin panther conductor. , supply of terminal connector of 132kv isolator suitable for twin panther conductor.

State Government

CTN :45313067 Due date: 25 May, 202625 May, 2026 268.27 Crore
Tender For (i) construction of lilo of 220 kv d/c chapra (new) - gopalganj tr. line at gss mairwa transmission line with acsr zebra conductor. (line length ? 50x2 = 100 rkm) (ii) construction of 132 kv dcds transmission line from 132/33 kv gss raghunathpur to 220/132/33 kv ais sub-station at gss mairwa with acsr panther conductor (line length - 50 rkm) (iii) construction of 132 kv dcds transmission line from 132/33 kv gss bhorey to 220/132/33 kv ais sub-station at gss mairwa with acsr panther conductor (line length - 55 rkm)

CTN :45277957 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For rate contract for supply of materials for 33kv lines and 33 by 11kv recieving stationsfor the year 2026-27. - 33 kv & 11 kv cable kits indoor/outdoor (make hot set or any other reputed make conforming to relevant is specifications) a) cable kits 33 kv single core heat shrinkable indoor 630 mm2, b) cable kits 33 kv single core heat shrinkable indoor 300 mm2, c) cable kits 33 kv single core heat shrinkable outdoor 630 mm2, d) cable kits 33 kv single core heat shrinkable outdoor 300 mm2, e) cable kits 11 kv single core heat shrinkable indoor 630 mm2, f) cable kits 11 kv single core heat shrinkable outdoor 630 mm2, g) cable kits 11 kv 3 core heat shrinkable indoor 400 mm2, h) cable kits 11 kv 3 core heat shrinkable indoor 300 mm2, i) cable kits 11 kv 3 core heat shrinkable indoor 240 mm2, j) cable kits 11 kv 3 core heat shrinkable indoor 185 mm2, k) cable kits 11 kv 3 core heat shrinkable indoor 120 mm2, l) cable kits 11 kv 3 core heat shrinkable outdoor 400 mm2, m) cable kits 11 kv 3 core heat shrinkable outdoor 300 mm2, n) cable kits 11 kv 3 core heat shrinkable outdoor 240 mm2, o) cable kits 11 kv 3 core heat shrinkable outdoor 185 mm2, p) cable kits 11 kv 3 core heat shrinkable outdoor 120 mm2, q) cable kits 11 kv 3 core (straight through joint), heat shrinkable 120 mm2, r) cable kits 11 kv 3 core (straight through joint), heat shrinkable 185 mm2, s) cable kits 11 kv 3 core (straight through joint), heat shrinkable 240 mm2, t) cable kits 11 kv 3 core (straight through joint), heat shrinkable 300 mm2, u) cable kits 11 kv 3 core (straight through joint), heat shrinkable 400 mm2, v) cable kits 11 kv single core (straight through joint), heat shrinkable 630 mm2, w) cable kits 33 kv single core (straight through joint), heat shrinkable 630 mm2, 11 kv cts of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm for 11 kv ocb/ vcb panelsi) 800/400/5-5, ii) 750/375/5-5, iii) 600/300/5-5, iv) 400/200/5-5, v) 300/150/5-5, vi) 150/75/5-5, spares for power transformersa) breather for 6.3 mva 33/11 kv transformer (2 kg), b) breather for 1.6 mva 33/11 kv transformer (kg), c) breather for 3.15 mva 33/11 kv transformer (kg), d) breather for 10 mva 33/11 kv transformer (3 kg), e) breather for 5 mva 33/11 kv transformer (2 kg), f) 20 mm lt bush rod for 33/11 kv transformer, g) 12 mm lt bush rod for 33/11 kv transformer, h) 20 mm copper bush rod assembly for 33/11 kv, 10 mva power transformer with oil seal, i) 12 mm copper bush rod assembly for 33/11 kv, 6.3 mva power transformer with oil seal, j) silica gel, k) oil seal for 33/11 kv power transformer, l) adaptor for bush rod extension for 33/11 kv power transformers, relays a) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make .(scada compatible), b) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make.(non-scada compatible), c) master trip relay 24-50 v ,of different make, 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification a) 33 kv pin insulator with pins (porcelain type), b) 33kv pin insulators for panther conductor with pins (polymer type), c) 33kv pin insulators for wolf conductor with pins (polymer type), d) 33kv pin insulators for dog conductor with pins (polymer type), e) 33 kv g.i. pins, f) 11 kv pin insulator (polymer type) with pins, g) 11 kv pin insulator (porcelain type) with pins, h) 11 kv g.i. pins, i) 11 kv disc insulator (b & s type) 70 kn (porcelain type), i) 11 kv disc insulator (b & s type) 120 kn (porcelain type), j) 33kv disc insulators (polymer type), k) 33 kv post insulator, l) 22 kv post insulator, m) 11 kv post insulator, n) drive insulator of sorts, o) shackle insulator, p) 11 kv guy insulator, q) 33 kv guy insulator, 33 kv tension fittings for acsr dog conductor, b&s 3 u-bolts type, 33 kv tension fittings for acsr wolf conductor, b&s 4 u-bolts type, 33 kv tension fittings for acsr panther conductor, b&s

CTN :45271786 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For rate contract for supply of material required for repair/maintenance /restoration of 33kv lines and 33/11kv receiving stations in respect of std-iv kalakote, for the year 2026-27 or till next contract. - 33 kv & 11 kv cable kits indoor/outdoor (make hot set or any other reputed make conforming to relevant is specifications) a) cable kits 33 kv single core heat shrinkable indoor 630 mm2, b) cable kits 33 kv single core heat shrinkable indoor 300 mm2, c) cable kits 33 kv single core heat shrinkable outdoor 630 mm2, d) cable kits 33 kv single core heat shrinkable outdoor 300 mm2, e) cable kits 11 kv single core heat shrinkable indoor 630 mm2, f) cable kits 11 kv single core heat shrinkable outdoor 630 mm2, g) cable kits 11 kv 3 core heat shrinkable indoor 400 mm2, h) cable kits 11 kv 3 core heat shrinkable indoor 300 mm2, i) cable kits 11 kv 3 core heat shrinkable indoor 240 mm2, j) cable kits 11 kv 3 core heat shrinkable indoor 185 mm2, k) cable kits 11 kv 3 core heat shrinkable indoor 120 mm2, l) cable kits 11 kv 3 core heat shrinkable outdoor 400 mm2, m) cable kits 11 kv 3 core heat shrinkable outdoor 300 mm2, n) cable kits 11 kv 3 core heat shrinkable outdoor 240 mm2, o) cable kits 11 kv 3 core heat shrinkable outdoor 185 mm2, p) cable kits 11 kv 3 core heat shrinkable outdoor 120 mm2, q) cable kits 11 kv 3 core (straight through joint), heat shrinkable 120 mm2, r) cable kits 11 kv 3 core (straight through joint), heat shrinkable 185 mm2, s) cable kits 11 kv 3 core (straight through joint), heat shrinkable 240 mm2, t) cable kits 11 kv 3 core (straight through joint), heat shrinkable 300 mm2, u) cable kits 11 kv 3 core (straight through joint), heat shrinkable 400 mm2, v) cable kits 11 kv single core (straight through joint), heat shrinkable 630 mm2, w) cable kits 33 kv single core (straight through joint), heat shrinkable 630 mm2, 11 kv cts of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm for 11 kv ocb/ vcb panelsi) 800/400/5-5, ii) 750/375/5-5, iii) 600/300/5-5, iv) 400/200/5-5, v) 300/150/5-5, vi) 150/75/5-5, spares for power transformersa) breather for 6.3 mva 33/11 kv transformer (2 kg), b) breather for 1.6 mva 33/11 kv transformer (kg), c) breather for 3.15 mva 33/11 kv transformer (kg), d) breather for 10 mva 33/11 kv transformer (3 kg), e) breather for 5 mva 33/11 kv transformer (2 kg), f) 20 mm lt bush rod for 33/11 kv transformer, g) 12 mm lt bush rod for 33/11 kv transformer, h) 20 mm copper bush rod assembly for 33/11 kv, 10 mva power transformer with oil seal, i) 12 mm copper bush rod assembly for 33/11 kv, 6.3 mva power transformer with oil seal, j) silica gel, k) oil seal for 33/11 kv power transformer, l) adaptor for bush rod extension for 33/11 kv power transformers, relays a) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make .(scada compatible), b) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make.(non-scada compatible), c) master trip relay 24-50 v ,of different make, 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification a) 33 kv pin insulator with pins (porcelain type), b) 33kv pin insulators for panther conductor with pins (polymer type), c) 33kv pin insulators for wolf conductor with pins (polymer type), d) 33kv pin insulators for dog conductor with pins (polymer type), e) 33 kv g.i. pins, f) 11 kv pin insulator (polymer type) with pins, g) 11 kv pin insulator (porcelain type) with pins, h) 11 kv g.i. pins, i) 11 kv disc insulator (b & s type) 70 kn (porcelain type), i) 11 kv disc insulator (b & s type) 120 kn (porcelain type), j) 33kv disc insulators (polymer type), k) 33 kv post insulator, l) 22 kv post insulator, m) 11 kv post insulator, n) drive insulator of sorts, o) shackle insulator, p) 11 kv guy insulator, q) 33 kv guy insulator, 33 kv tension fittings for acsr dog conductor, b&s 3 u-bolts type, 33 kv tension fittings for acsr wolf

corporations/Associations/Others

CTN :44726454 Due date: 08 Jun, 202608 Jun, 2026 90.52 Lacs
Tender For corrigendum : work of erection of 66kv s/c line on d/c towers from prop. 220kv mandan (mota asarana) s/s to exi. 66kv mota khuntavada s/s with stringing of al-59 conductor (equivalent weight of acsr panther conductor) having approx. length of 10.10 rkm approved under kisan suryodaya yojana phase-ii.
 Loading, Please wait...

Connect us via What's Up