Get complete information related to latest Paper Dish Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Paper Dish Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Paper Dish Tenders.
Tender For supply of rem polyhesive infant patient return electrode console is of covidien (medtronic) and this disposable (consumable) item should be of same company. bis/ ce certified
Tender For supply of nutrient agar plate. spec: 1. it should be ready made solid culture media in 90mm disposable petri plate used for bacterial culture with minimum 4 mm thickness. 2. should be suitable for isolation and enumeration of bacteria from clinical specimens. 3. media should be non- selective for isolation of different pathogens. 4. manufacturer firm should have iso/bis+who gmp/european ce/fda/any recognised international council approval certification. 5. media should have a minimum shelf life of 3 months. 6. biomedical waste generated from the plastic petri plate should not generate carcinogenic byproducts on incineration/autoclaving/microwaving. 7. performance should be demonstrated to the satisfaction of end user with each new batch supplied. 8. it demonstrates good batch-to-batch reproducibility. ( rate to be quoted each plate basis ) [ai(2025-26) , item code no.s-60737, sl. no.1233]
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For supply of chrome uti agar plate. spec: 1. it should be ready made solid culture media in 90 mm disposable petri plate used for bacterial culture with minimum 4 mm thickness. 2. should be suitable for isolation and enumeration of bacteria from clinical specimens. 3. media should contain selective ingredients for inhibiting swarming of proteus and isolation of major uropathogens- gnb and gpc both. 4. manufacturer firm should have iso/bis+who gmp/european ce/fda/any recognised international council approval certification. 5. media should have a minimum shelf life of 3 months. 6. biomedical waste generated from the plastic petri plate should not generate carcinogenic byproducts on incineration/autoclaving/microwaving. 7. performance should be demonstrated to the satisfaction of end user with each new batch supplied. 8. it demonstrates good batch-to-batch reproducibility.( pack of 50 plates)[ai(2025-26) , item code no.s-60733, sl no.1229.]
Tender For corrigendum : supply of lab item - insulin pump disposable quickset and reservoir , elite h 580 dil 1 multiple 20l , elite h 580 lyse 1 1 multiple 500ml , elite h 580 lyse 2 1 multiple 500ml , elite h 580 lyse 3 1 multiple 1000ml , elite h clean 1 multiple 50ml , elite h 580 con h n l 3 multiple 3ml , elite h 580 cal 1 multiple 3ml , ready to use lj media slant in mac cartney bott , disposable petridish plates , koh , cryptococcol antigen lateral flow assaybox of 20 kits , nicrome wire loop , gram stain , stain solution kit ready to use for acid fast bacteria with acid fast decolouriser carbol fuchsin and methylene blue in 125ml bottle each , prepared cled agar plate , pre prepared agar plate mac conkey medium , 0 point 45 saline sol to be used along with vitek 2 pack of 3 500 ml