Web Analytics Made Easy - StatCounter

Parcel Scanner Tenders

Get complete information related to latest Parcel Scanner Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Parcel Scanner Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Parcel Scanner Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :41709045 Due date: 29 Sep, 202529 Sep, 2025 NA
Tender For supply of interior stickers with braille script for lhb ac 3 tier coaches. , as per drawing: le64016 alt b item no 1 to 7, 9 to 11,13, 15, 18 to 22,27 & 29 with braille script to icf/md/spec-253 rev.00, amd-02.packing instruction: lettering inside: one complete set of lettering inside should be packed in cardboard box. different subsets should be made &a list of items should be pasted on each packet of subsets. letters packed in each subset under different headings are as under:- plumbing : emergency flush button, press for flush, notice for bio toilet moulding:- duties of coach attendant, push, pull, no smoking,alarm and penalty notice, door closes automatically, safety message near gate, notice for luggage capacity. lavatory:- dust bin, fire extinguisher, soap dispenser, no drinking water, no waste into toilet, western style, press for flush, fire prevention and safety,marking of lavatories / body side door, notice for lavatories, drinking water, unified notice for fire prevention & safety. seat & berth:- sticker for seat number, berth numbers, letter for chaining luggage, notice for unreserved coaches. air brake:- reset emergency brake, feed pipe, brake pipe, closed, open, hand brake panel : furnish plate, complaint book. window & ceiling: pull window glass inside, indication plate & sticker for emergency window, emergency openable window the cardboard box shall carry a qr code having details as listed below : 1 name of the manufacturer 2 purchase order number 3 purchase order date 4 unique serial number (or lot number for bulk items) of the manufacturer or 5 date of manufacture 6 delivery challan no. 7 delivery challan date the qr code shall be as per iso/iec18004 model2 and the data shall be available as xml using the tags detailed above. incase the above details are not available, or the qr codes are not readable, the supplied material is liable to be rejected.

Central Government And Public Sector

CTN :41477607 Due date: 22 Sep, 202522 Sep, 2025 NA
Tender For corrigendum : supply of intelligent multi-criteria detectors for upgradation of fire protection system , manual call point for upgradation of fire protection system , zone monitoring unit for upgradation of fire protection system , monitor module for upgradation of fire protection system , relay module for upgradation of fire protection system , loop powered remote hooters for upgradation of fire protection system , repeat response indicator for upgradation of fire protection system , fas control panel having 8 loop capacity with redundant cpu , zone indicating panel for upgradation of fire protection system , fire alarm control panel having 2 loop capacity with single controller , lcps -bare cabinets for upgradation of fire protection system , standalone ac to dc psu-smps for lcps for upgradation of fire protection system , hand- switches, push buttons, indicating lamps for upgradation of fire protection system , loop powered-cpu motherboard- backplane- bus powered relay modules with at least 8 change over contacts for upgradation of fire protection system , spares for fas control panel min. one type of each card or 10 percentage whichever is more standalone psu etc. , spares for relays other loose components and modules. for upgradation of fire protection system , test meter for smoke detectors , smoke detector removal tool kit with 6 m collapsible-concentric rod , smoke detector testing tool kit , aerosol gas cans 250 ml , heat detector tester , 1 pair 1.5sq. mm overall shielded hrpvc insulated frls pvc sheathed un-armoured cable for upgradation of fire protection system , 5 pair individually shielded 1.5sq.mm hrpvc insulated frls pvc sheathed unarmoured cables for upgradation of fire protection system , 10 pair individually shielded 1.5sq.mm hrpvc insulated frls pvc sheathed unarmoured cables for upgradation of fire protection system , 19 mm flexible gi conduit for upgradation of fire protection system , supply of 25 mm rigid hot dipped gi conduit including accessories , supply of nickel plated double compression brass cable glands , other accessories mcbs sealing compound etc , installation and commissioning of the system for upgradation of fire protection system

corporations/Associations/Others

CTN :41567581 Due date: 12 Sep, 202512 Sep, 2025 NA
Tender For corrigendum : providing of custom bid for services - on site service charges addressable fire alarm panel make: nsc, model: solution f1

Central Government/Public Sector

CTN :41666680 Due date: 23 Sep, 202523 Sep, 2025 47.51 Lacs
Tender For repair /maintenance of water supply installation including pumps, starter, panel distribution at icgs kakinada, malkapuram, jetty complex and fire alarm system and fire fighting system including allied works at icgs malkapuram under ge(i)(cg)vizag

Central Government And Public Sector

CTN :41687518 Due date: 24 Sep, 202524 Sep, 2025 NA
Tender For supply of module for fire fighter system d d - 1_power module -part no -fa _ 5_ ps 501 of _ safeway security systems make panel for fire alarm and extingushant _gas_ release panels as per attach boq specification , 2_monitor module card-part no. _fa_5_mm _502-b of safeway security systems make panel for fire alarm and extingushant _gas_ release panels as per attach boq specification , 3_control module card -part no. _fa_5_cm_503-a of safeway security systems make panel for fire alarm and extingushant_gas_release panelsas per attach boq specification , 4_zone module card- part no._ fa_5_zm_504-c of safeway security systems make panel for fire alarm and extinguishant _gas_ release panels as per attach boq specification , 5_mode selector module card -part no. _fa_5_m_517-b of safeway security systems make panel for fire alarm and extinguishant_gas_release panels as per attach boq specification , 6_dv module card-part no. _fa_5_dv_520 of safeway security systems make panel for fire alarm and extinguishant _gas_release panels as per attach boq specification , 7_gas module card _ model- fa_5_gm_505_ for safeway security systems panel for co2 fire fighting for dg_model no-s-5, serial no-7846_as per attach boq specification , 8_sounder module -part no._fa_5_zm_504-c_s_of safeway security systems make panel for fire alarm and extingushant_gas_release panels as per attach boq specification ) /bid number : gem/2025/b/6636709 * /dated: 03-09-2025 & & / bid document 1 / 11

corporations/Associations/Others

CTN :41704963 Due date: 12 Sep, 202512 Sep, 2025 NA
Tender For auction sale of fire alarm panel without internal compon

Central Government/Public Sector

CTN :41441558 Due date: 10 Sep, 202510 Sep, 2025 40.45 Lacs
Tender For corrigendum : repair/ maint of lt electric supply in grd and ncc and flame proof wiring with concealed pipe, flame proof fittings, fire alarm system with fire panel and connected items at af stn under ge af gorakhpur

Central Government/Public Sector

CTN :41702886 Due date: 08 Sep, 202508 Sep, 2025 NA
Tender For supply of repeater panel (remote keypad) bosch make of fire alarm and detection system at 4x270 mw btps manuguru site

Central Government And Public Sector

CTN :41617153 Due date: 18 Sep, 202518 Sep, 2025 NA
Tender For supply of m/s morley ias by honeywell make fire alarm system panel and its spare lcd display

Central Government/Public Sector

CTN :41596971 Due date: 16 Sep, 202516 Sep, 2025 42.58 Lacs
Tender For provision of external electric supply for 661 sailors inliving accommodation at visakhapatnam - supply, installation, testing and commissioning of outdoor type step down transformer 1000 kva 11kv/433v dyn11 oil filled (onan) distribution transformer double copper wound with radiator wall with conservator tank & porcelain bushing for ht, lt with off circuit tap changer, marshalling box all as per is 1180 (part-1) : 2014, bee certified, energy efficiency level ii (as per latest ammendment no 4) complete as directed., a) off circuit tap changer (octc), tapping range +5% to -10% in a steps of 2.5% per step (7 positions)b) temp. rise shall be 40/45 deg. c for oil/winding resp. over an ambient of 50deg.c tempc) insulation class: ad) losses ( subject to is 1180 efficiency level 2/ star 2 as per latest amendment 4) max. total loss @ 50% loading: 2620 w and max. total loss at 100% loading: 7000 w.e) % impedance (%z) shall be 5.00% (subject to is tol.)f) rating & diagram (r&d) plate (fitted on transformer)g) oil temp. indicator (oti) with alarm and trip contacth) winding temp. indicator (wti) with alarm and trip contactj) rated temp class of transformer compartment k10 upto 1000kvak) lifting lugs/ hooks for transformer.l) oil filling inlet pipe with plug.m) air release valve and drain out pipe with plug.n) conservator tank with level guage.o) silica gel breatherp) first oil fill up to recommended level by manufacturer with new oil as per is 335.q) cable terminal boxes with bushes on both ht and lt sides.r) hv winding: delta & lv winding: star.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply and fixing main lt panel cpri approved made out of crca sheet 3.15 mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per al bus bar rated with insulators suitable for three phase and four wire lt ac, 50 hz 415 v 2000 a capacity complete with powder coating, necessary internal electric connection as required and provision of the following : (main lt panel)., incoming:air circuit breaker 1600 amps, 50 ka, mdo type, 4 pole, micro processor release, with adjustable type overload protection, short circuit protection, with necessary cts, meters and cable boxes. - 1 no.outgoing:a) mccb 250 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 07 no (bldg vtpn 02 nos, bldg panels 04 nos + spare)b) mccb 140 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (dg amf panel)c) mccb 160 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (ff panel)d) mccb 100 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (apfc panel)e) intelligent panel meter to measure voltage, current, frequency, power factor, kwh etc with all connected cts.f) led indicating lamps with colour red, yellow, blue of 03 sets.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply & fixing of perforated gi cable tray of size 150 mm width x 50mm depth x 1.6mm thickness with perforations not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with gi suspenders including bolts & nuts etc as req
 Loading, Please wait...

Connect us via What's Up