Web Analytics Made Easy - StatCounter

Paver Brick Tenders

Get complete information related to latest Paver Brick Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Paver Brick Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Paver Brick Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45732633 Due date: 02 Jul, 202602 Jul, 2026 49.8 Thousand
Tender For bhoj dharti,bhoj darara,bhoj mataur, group of 3 no. of habitations annual mtc.works for water supply - providing and laying of base course of floors, providing and laying of conglomerate floor, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, brick work with common burnt clay non-modular bricks of class. cement plaster on rough side of single or half brick wall.

State Government

CTN :45732647 Due date: 02 Jul, 202602 Jul, 2026 49.6 Thousand
Tender For bhoj dharti,bhoj darara,bhoj mataur, group of 3 no. of habitations annual mtc.works for water supply - demolishing dry brick pitching in floors, drains etc, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, steel reinforcement for r.c.c. work, brick work with common burnt clay modular bricks of class. cement plaster.

Corporations And Associations And Others

CTN :45563054 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : e-tender for civil contract jobs - civil contract job:, earth filling under floors with surplus ordinary soil or soil containing gravel or kankar, including ramming, watering and consolidated lead., first class burnt brick work laid in cement sand mortar 1:7 in foundation and plinth, laying 80 mm thick factory made cement conc. inter locking paver bricks after m-40 grade made by block making machine with string vibratory compaction ordinary gray color & pattern over 50 mm thick compacted bed of coarse sand filling the joint with fine sand, complete in all respect ., dismantling brick of flagged stone flooring including concrete base, dismantling concrete plain 1:2:4 mix, cement concrete 1:2:4 with stone ballast or shingle, a. mixing by manual mean, b. mixing by mechanically mean using concrete mixer, laying of dry brick ballast 40mm gauge for flooring, civil work (rate to quoted on csr rates)

State Government

CTN :45705895 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For cement plaster (in fine sand) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) ,steel door/ window frames and shutters providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. using m.s. angels 40x40x6 mm for diagonal braces, sigle/built-up steel/tubular sections steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. in stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete,cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level a,brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 (1 cement : 4 coarse sand)

State Government

CTN :45705900 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 3. 1:2:4 (1 cement : 2 coarse sand (zone-iii) : 4 graded stone aggregate 40 mm nominal size) ,brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor iv level in all shapes and sizes in : 1. cement mortar 1:4 (1 cement : 4 coarse sand),ement plaster

State Government

CTN :45705821 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with is : 5382 and testing of spigot and socketted rcc, np2 marked with is : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the engineer - in -charge. 4. 350 mm i/d ,`jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special , earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by engineer-in-charge. 1. all kinds of soil ,cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 3. 1:2:4 (1 cement : 2 coarse sand (zone-iii) : 4 graded stone aggregate 40 mm nominal size),brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. cement mortar 1:6 (1 cement : 6 coarse sand), cement plaster (in fine sand) 12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)

State Government

CTN :45702917 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 (1 cement : 4 coarse sand) ,lan and reinforced concrete pipes `jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special being. ` 7. 350 mm internal diametre sewer pipe

State Government

CTN :45702921 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 (1 cement : 4 coarse sand) ,lan and reinforced concrete pipes `jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special being. ` 7. 350 mm internal diametre sewer pipe

State Government

CTN :45705912 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For fixing bell mouths bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the engineer-in-charge. size of the main with which connection is to be made. 1. up to 200 mm internal diametre ,manhole chambers providing and fixing sfrc manhole covers and frames marked with is: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the engineer-in-charge. 1. type:- extra heavy duty set (ehd-35) 560mm clear opening, earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by engineer-in-charge. 1. all kinds of soil ,demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2. nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 6. 1:4:8 (1 cement : 4 coarse sand (zone-iii) : 8 graded stone aggregate 40 mm nominal size) .,steel reinforcement steel reinforcement for r.c.c. work, where not included in the complete rate of rcc, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level note: reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. thermo-mechanically treated bars of grade fe-500d or more,brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor iv level in all shapes and sizes in : 1. cement mortar 1:4 (1 cement : 4 coarse sand)

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
 Loading, Please wait...

Connect us via What's Up