Get complete information related to latest Pcb Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pcb Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pcb Scrap Tenders.
Tender For procurement of mitsubishi electrical co. make excitation system (avr) spares installed at 2x660 mw, sstpp, mppgcl, dongalia/etni-ii - relay srld-k100 mitsubishi dc48v,143ma contact:220dc,1a, resistor for initial excitation snubber circuit r-315 gh 40w-500-ohm resistance, relay srd-t9 dc48v,143ma contact:220dc,1a, capacitor for dc surge absorber circuit (fl17c106kxtuba) (fluba) 10 micro f, resistor for dc surge absorber circuit 5kw 50 ohm (gh200w 50-ohm 5pss), capacitor for initial excitation ket-1942 flaba 0.5 micro f (ge11085),550 vac, capacitor initial excitation snubber circuit (eb931010dxa2924) 1 micro f,930 vdc, test volt. 4000 vdc, capacitor for ac surge absorber circuit 0.8 micro f fl12c804kbdrba(flrba) , resistor for ac surge absorber circuit 800w 50-ohm resistance (gh 400w 100-ohm 2p 15x3a), srld-k100 (51h) coil:220v dc, 34ma contact:220dc,1a, differential pressure switch ms30hv500d (50-500 pa) 2a, 30vdc, annunciation system slc30n (szm-1124) idec ac/dc 24v, aux. vt/ct (szm-1190-001) i/p ct-5a, o/p-5v, i/p pt-120v, o/p-5v, diode for dc control power sanrex kd60hb-160, resistor for initial excitation gh 20w 200 ohm, thyristor card outline 65x75, 48v dc power board mss-150-48g dc48v 150w, 24v dc power board mss-150-24g dc24v 150w, meter for field current lm-110nda (0-11ka) fs (0-100mv), meter for field voltage lm-110ndv (0-1200v) fs (0-1ma), thyristor for field discharge n880ch west code, relay srd-t9 dc24 v,293ma contact:220dc,1a, nfb for dc power supply nf32-sv 2p dc250v 10a, nfb for ac power supply nf32-sv 2p ac600v 10a, thermistor e52-the6f range:0-100 deg c, selection switch ut-2t 500v,30a, resistance for 41sa type- gh nittei 20 w 10k?, test terminal (vt), tt4p, ac250v,10a, test terminal (ct), tt4c, ac250v,10a, switch for fan ar30pr-233b ac110v,6a, selection switch ar30pr-233b dc220v,1a, fuse for transducers cello lite fuse- d15g0, d.c. 1500v, 5a, b.c. 23 ka d3797
Tender For supply of ffd1 a ac input fuse fail detector circuit, mt 111, 415v12v dc,con101 a 3 pole ac input mains contactor, mnx 70 cs97076booo,63a,230v ac 70a,tr2a control transformer class b insulation with temperature rise class a 415240v ac, 500va,converter 1a,2a ac to dc converter,lrs 100 48 , ip 230vac, op 48v dc2.3a,tr1a three phase, double wound, impregnated naturally air cooled, mains transformer class h insulation and temperature rise limited to class f, input power transformer,32.15 kva, 45670v, 70v,ipt 1a inter phase transformer,0.65kva,ffd2a 3a, rectifier fuse fail detector circuit modified for latching facility using one extra relay and pb mounted on same pcb card used for trip function, mt 111,70v ac, aux. supply 12v dc,mr1a 2a 3 phase, full controlled, full wave rectifier bridge comprising of scr with heat sink and surge suppression networkt250e160,scr 170a1600 piv, 250a1600 piv,df a free wheeling diode,150nd160,150a1600piv,ffd5a free wheeling diode fuse fail detector circuit modified for latching facility using
Tender For supply of static frequency convertor , star delta change over pcb , series regulator circuit vard , ac signal amplifier pcb , 3 phase ref transformer pcb , dc output control card , dc control card , output control card
Tender For special repairs replacement to e/m equipments and infrastructure at af stn jamnagar under ge (af) jamnagar no 1 - supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410 a/r-32 (b) eer- 5 star rating (c) tonnage - 1.5 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410a/r-32 (b) eer- 5 star rating (c) tonnage - 2 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., note for item no 1 & 2 :- the cost of following items deemded to be included in quoted rate.(a) copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) ms bracket for outdoor unit duly power coated with fixing arrangement.(c) making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall.(d) testing and commissioning of the air conditioner to the entire satisfaction of engineer in charge(e) pvc round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) taking down of existing ac and deposited to e/m store yard without any damage., supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 4 kva as specified as directed by engineer-in-charge., supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 5 kva as specified as directed by engineer-in-charge., material & labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 sqmm each, pvc insulated, unsheathed, fire retardant, low smoke (frls) drawn through and including pvc casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 sqmm, pvc insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by engr-in-charge.note: 2 runs of main copper conductor, one run earth wire and pvc casing capping will be measured as one running meter for payment., s&f sheet metal enclosure , 20a single pole and neutral with a two pin and earth plug and socket complete in metal clad board (industrial type) with one single pole mcb 32 amp fixed properly on in concealed position all as specified as directed by engineer-in-charge., supply, installation, commissioning and testing in replacement of loop card having 254 devices of both detectors and modules in a single line circuit, slc supports both class a and class b wiring complete as specified and as directed by engineer-in-charge. make: ravel/honeywell/ceasefire industries pvt ltd, supply, installation, commissioning and testing in replacement of addressable smoke detector with base with binary coded address setting. dual leds for 360 visibil