Get complete information related to latest Peep Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Peep Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Peep Valve Tenders.
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,9cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels up to and including 5mm in diameter, with ergonomic symmetrical finger ring grip-focus 9, hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,17cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels upto and including 5mm in diameter, with ergonomic symmetrical finger ring grip- focus 17, double wall resuscitator with peepvalve in paediatricsit should be fully autoclavable double wall with hand strapit should be supplied with autoclavable reservoir bag it should have a singleshutter valve system made of silicone rubberit should have easy attachment of peepvalve for peadiatricit should have provision to attach manometer for paediatrics ambu bagbag volume: mark iv baby (300 ml)weight: baby (190 g)it should be us-fda, ce & iso certified, ultrasorbs ap disposable drypads,dry pad for moisture management, 58.4x90cm, with breathable layer, super absorbent core, aqua shield film and air permeable back sheet, absorbency of 1800- 2300gm, usfda/ce/biscompliant, iso13485 compliant, volumetric incentive spirometer (adult) volumetric incentive spirometer (adult) 4000 ml with handle. volume measurement must be compact comfortable designed to accommodate large inspired volumes. must have good-better-best flow window & advanced, low work-of-breathing design.particulate filter screen in device housing must help to reduce risk of foreign matter passing to patients.expandable and collapsible tube must help patients find comfortable position for treatments and can be removed when storing the device. ergonomic swiveled mouthpiece allows to patients create tight seal to enable more accurate measurement. flow indicator with smiley face provides visual target for desired inhalation and bright green flow indicator make it easy for patients to see results. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k &ce certification., neonatal high flow cannula having 8 litreflow. it can also be used for hfnc + nippv/cpap. should have a soft tip., pur-xro catheter 20 cm, 28g/1fr picc line with stylet, splitting needle with securing wings with 8cm extension tubing ( flow rate 0.7ml/min)., pur-xro catheter 30 cm, 24g/2fr picc line with split cannula and 10cm extension tubing over catheter (flow rate 4.5ml/min)., silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection caps, symmetrical tip retrograde and antigrade long term double lumen dialysis catheter size 15 fr x 23 cmusfda certification, "sterile disposable perfusion set (infusion set) with airway and needle (paediatric use) burette type measured volume chamber of 100 ml drop size of approx 60 drops per ml injection port,latexfree, for intermittent medication. floating auto shut off valve (latex free) in burette. soft and kink resistant pvc tubing. roller controller for flow control tube length 150 cm 23g needle as per iso 8536-5", "plaster of paris bandages 15cm x 2.7mts / roll testing parameter should befollowed as per bp standard", urine collecting bag, disposable 2000 ml transparent sh
Tender For corrigendum : supply of 1. cartridge heater and sensor -set of heaters and sensors for twin tcd, injector and oven along with porcelain connector and rosemary connector. part no. cic-dva-h and s , 2. oven fan motor, part no. cic-dva-ofm , 3. pr502 temperature controller, part no. cic-dva-pr502 , 4. one 10 port auto gsv with two solenoid valves, part no. cic-dva- auto-gsv , 5. rs 232 to rs 485 converter pcb, part no. cic-dva-con-pcb , 6. set of columns 2 meters x 0.125 inch od - mol. sieve 13x 2 meters x 0.125 inch od- porapak q , part no. cic-dva-col , 7. 24 volt 5 ampere eapl smps, part no. cic-dva-smps , 8. tcd detector, 4 filament- direct replacement with connector, part no. cic-dva-tcd , 9. tcd amplifier with power supply board, display pcb, pot meters. current pcb and transformer. part no. cic-dva-tcda