Tender For submission of a rate schedule for machinery and equipment to prepare an estimate for installing rainwater harvesting systems in stormwater lines and low lying areas along main and internal roads within the municipal corporation limits. - item name, providing and constructing recharge pit of 2.0m deep and 1.0m dia of precast rcc rings with 6.5 dia. x 25m deep bore well at the floor of recharge pit including providing and supplying one complete ai-enabled single integrated modular smart groundwater recharge unit with recharge-volume measurement, real-time clog monitoring, recharge-water quality monitoring, soil quality / site suitability assessment, iot communication, ai dashboard and gis monitoring platform, suitable for urban rainwater and storm water groundwater recharge applications. the supplied unit shall be a single integrated smart recharge unit and shall not be a combination of disconnected or separately assembled devices. all field-level hardware, sensors, filtration arrangement, sedimentation section, recharge-volume measurement system, real-time clog monitoring system, recharge-water quality monitoring system, iot controller, communication module, qr/gis asset identification and data communication components shall be integrated within the supplied smart recharge unit and shall operate as one complete system. the ai dashboard, gis monitoring platform, cloud hosting, sim/data communication and software support shall be digitally integrated with the supplied unit for live monitoring, alerts, analytics and reporting. internal components shall not be treated as separate payable items. the main body / modular assembly of the unit shall be made primarily from hdpe/frp / upvc or equivalent corrosion free material and shall be suitable for long-term contact with rainwater / storm water, groundwater recharge applications and repeated cleaning. the unit shall be corrosion-resistant, water-resistant, durable and easy to maintain. the unit shall be modular, removable, reusable and serviceable. the design of the unit shall enable cleaning, sediment removal, filter inspection, filter-media replacement, sensor inspection and refitting without damaging the surrounding civil structure, chamber or recharge arrangement. the unit shall have a minimum external diameter of 750 mm and minimum overall height of 2000 mm with frp cover of suitable size having 40 mt capacity. the unit shall have sufficient internal space for filtration arrangement, sediment holding, recharge-volume measurement, real-time clog monitoring, water-quality monitoring, iot components, sensor housing, cleaning access and maintenance. the unit shall include multistage filtration, debris arrest arrangement, first-flush / bypass provision, sedimentation and silt-management section, recharge-volume measurement system, recharge-rate monitoring, real-time clog monitoring, recharge-water quality monitoring after filtration and before recharge, soil quality / site suitability assessment module, iot-based data communication, qr, gis asset identification, ai-enabled web dashboard, gis monitoring platform. the unit shall be capable of measuring, recording and reporting actual recharge volume, recharge-rate trend, sedimentation status, clogging condition, recharge-water quality parameters, soil / site suitability parameters, unit health, sensor health, battery status, communication status and maintenance status on a web-based dashboard. the item shall be treated as one complete integrated smart unit. internal components such as hdpe/ frp modular body, filtration arrangement, sedimentation section, measurement systems, sensors, iot controller, communication module, ai dashboard, gis platform, cloud hosting and sim/data support shall not be measured or paid separately. the unit shall have authentication from any govt. institute like c.o.e.p./cw&prs/gsda etc. the unit shall be supplied with five years warranty against manufacturing defects, material defects and functional failur
Tender For supply, installation, testing and commissioning of hydrological, soil moisture and water flow monitoring instruments - woltman type water meter, tensiometer, soil moisture sensor, redox potential sensor, ultrasonic water level, sensor - radar based, ultrasonic flow velocity, sensor - radar based, infiltrometer, supply and installation of parshall flume (6") , discharge measurement 0.1 to 8.7 i/s, supply and installation of parshall flume (12") , discharge measurement 0.9 to 49 i/s, automation of water level recording system in parshall flume.
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For providing of system integration service to implement iot sensor-based measurement and monitoring of rural water supply systems - display unit for village level dashboard; cellular technology (2g/3g/4g); hybrid model
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c
Tender For tender for repairing and calibration of temperature indicators installed on boiler , work of repairing, calibration and rewiring of superheated wash water temperature control system , laying of comprehensive cable, installation of thermocouple and commissioning of indicators at the boiler station , work of repairing, rewiring, overhauling and commissioning of d- superheating system of exhaust line , repairing and commissioning work of temperature indicators of sulfur furnace , laying of compressive cables of sulfur furnace, installation of sensors and commissioning of temperature indicators , to carry out installation and commissioning work for raw-sulfated juice, clear juice, exhaust steam and injection water inlet temperature , over hauling, rewiring and recommissioning of auto drum water level control system of boilers , rewiring and recommissioning of high or low alarm system on boilers for water level , overhauling, rewiring and recommissioning of boiler steam generation system , overhauling, rewiring and recommissioning of boiler feed water measurement system
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam