Get complete information related to latest Pf Capacitor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pf Capacitor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pf Capacitor Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For supply and delivery of leakage materials for maintenance of water supply in vikarabad municipality under municipal general funds - supply, fixing, testing & commissioning of 200 mm diac.i. gate valves os &y as per is:14846 ( pn 10 rating) and rising spindle type with flanges, bolts, nuts, washers, gaskets etc. the valve shall be fitted with chain lock and key arrangement . , supply, fixing, testing & commissioning of 150 mm diac.i. gate valves os &y as per is:14846 ( pn 10 rating) and rising spindle type with flanges, bolts, nuts, washers, gaskets etc. the valve shall be fitted with chain lock and key arrangement . , supply, fixing, testing & commissioning of 100 mm dia c.i. gate valves os &y as per is:14846 ( pn 10 rating) and rising spindle type with flanges, bolts, nuts, washers, gaskets etc. the valve shall be fitted with chain lock and key arrangement . , supply of heavy duty long barrel copper lugs confirming to i.s specifications suitable for 400 sq.mm cable etc complete with nuts, bolts and washers makes: dmi / jainson / dowels or equivalent make as approved by the department , supply of heavy duty long barrel copper lugs confirming to i.s specifications suitable for 150 sq.mm cable etc complete with nuts, bolts and washers makes: dmi / jainson / dowels or equivalent make as approved by the department , supply of 63a 3 pole mccb, 16ka adjustable, confirms to is/iec 60947-2 having breaking capacity ------ --------ka with thermal magnetic release panel mounted. makes : lk - d sine / schneider-ns nsx/legrand -dp x3/ siemens-3v / hager-h3 / -winbreak / bch / havells / eaton , supply of 6.0 sqmm wptc (weather proof twin core) isi mark alluminium wire.makes : polycab / gm / million / vguard / gold medal / kundancab / hpl / rpg / nandicab / nakoda / payal / finecab / gemini / vimal / suncab / stanjo /rajnigandha / orbit / airson / beljin / savera champion / rhino. elec-1.6.1 , supply of 2.5 sqmm 3 core pvc / xlpe insulated sheathed multi core bright annealed bare copper conductor heavy duty industrial cables for voltage grade upto 1100 volts as per is: 694:1990 including all transportation charges etc complete. makes : nakoda / sun cab / sudhakar / powerflex / gemni / ollvin / delton / airson / hpl / beljin / savera champion /rhino. elec-1.5.6 , supply of 1.5 sqmm 3 core pvc / xlpe insulated sheathed multi core bright annealed bare copper conductor heavy duty industrial cables for voltage grade upto 1100 volts as per is: 694:1990 including all transportation charges etc complete. makes : nakoda / sun cab / sudhakar / powerflex / gemni / ollvin / delton / airson / hpl / beljin / savera champion /rhino. elec-1.5.6 , supply and erection of push buttons on the existing panel board. makes : lk / / salzar / hpl/ siemens.elec- 8.17.6 , supply and delivery of power contactor of 80apm 3 pole (ac3 rating) for heavy duty electrical power loads including all charges etc., complete , supply and delivery of nut and bolts with watchers , supply and delivery of 6mm thick rubber packing excluding all taxes. , supply & fixing of d.o.l starter 250v, single phase, 50hz. with ss enclouser comprising of contactor with bi-metalic relay with necessary push buttons, etc., complete suitable up to 3hp makes: siemens / crompton / l&t / bch. , starting capacitor of 80 to 120 mfd. by new approved make capacitor suitable for compressor motor of 1.0 / 1.5 ton a.c. unit. , running capacitor of 36 mfd by new approved make capacitor suitable for compressor motor of 1.0 / 1.5 ton a.c.unit. , reducers - od 75 mm x 90 mm , reducers - od 125 mm x 140 mm , pvc / cotton insulation tape role ( 10mtrs) , od 90 mm tee , od 90 mm - end caps , od 75 mm - end caps , od 200 mm - end caps , od 125 mm tee , ms flanges - od 75 mm , ms flanges - od 200 mm , ms flanges - od 125 mm , 7.5hp motor rewinding , 7.5hp motor pump repairs , 7.5hp motor bushes repairs , 5hp motor rewinding , 5hp motor pump repairs , 5hp motor bushes repairs , 2hp motor re
Tender For tender for labour charges for service and maintenance of 1.5t and 2.0t ac , labour charges for routine or breakdown service and maintenance of 8.5t ac , labour charges for service and maintenance and maintenance of vrv and vrf , labour charges for service and maintenance air waher ventilators and scrubbers , chemical and other items required for servicing of ac, vrv and vrfs , topping up with suitable cooling gas of refrigerant in ac, vrv and vrf units , replacement of running capacitor 36 mfd, 240 v of 1.5t, 2.0t and 8.5t ac , replacement of running capacitor 45 to 50 mfd, 240 v of 1.5t, 2.0t and 8.5t ac , replacement of motor capacitor 2.5 mfd, 240 v of 1.5t, 2.0t and 8.5t ac , replacement of motor capacitor 4 mfd, 240 v of 1.5t, 2.0t and 8.5t ac , replacement of indoor fan motor of 1.5t, 2.0t and 8.5t ac , replacement of outdoor fan motor of 1.5t, 2.0t and 8.5t ac , replacement of condenser coil of 1.5t, 2.0t and 8.5t ac , replacement of cooling coil of 1.5t, 2.0t and 8.5t ac , supplying and replacement of pcb for 1.5tr and 2.0 tr inverter ac , supplying and replacement of pcb for 8.5 tr ac , repairing of pcb for 1.5tr and 2.0 tr inverter ac. , repairing of pcb for 8.5 tr inverter ac. , replacement of old burnt or defective compressor 1.5 tr ac compressor , replacement of old burnt or defective compressor 2 tr ac compressor , replacement of old burnt or defective compressor 8.5 tr ac compressor , replacement of magnet switch for vrv and vrf , replacement of motor capacitor 2-5 mfd, 240 v for vrv and vrf , replacement of motor capacitor 4 mfd, 240 v for vrv and vrf , replacement of outdoor fan motor for vrv and vrf , replacement of condenser coil for vrv and vrf , replacement of cooling coil for vrv and vrf , replacement of old burnt compressor for hot and cold type vrv and vrf , repairing of 8 to 12.5 hp monoblock pumps , repairing of 1 to 2 hp monoblock pumps , repairing and re-installation of starters for various pumps in air ventilators , replacement of old burnt starters for various pumps in air ventilators , replacement of old burnt connectors and contactors for pumps //bid details 2 / 33
Tender For supply of set of electrical maintenance kit. the details of items as follow : (i) heavy duty gi socket dia 50 mm x length : 100 mm as per is : 1239 part 1 2004 suitable for 50 mm gi pipe of bore well pump fittingmake : kirloskar or similar =01 no. (ii) capacitor running range 55+6uf, 6 pin for ac unit isi marked,440v,50hz ac as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 allu. container body make : epcos or similar = 01 no. (iii) capacitor running range 45+6uf, 6 pin for ac unit ,isi marked,440v,50hz ac as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 allu. container body make : epcos or similar =01 no (iv) capacitor running for ac unit isi marked, range 06 mfd pl top dfo 450v,50 hz ac as per is: 2993 part i : 24 or latest / iec 60252-2 : 2010 + amd 1 : 2013pl container lead type make : epcos or similar =01 no. (v) capacitor running for ac unit isi marked, range 10 mfd pl top dfo 440v,50 hz ac as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 pl container lead type make :epcos or similar =01 no. (vi) capacitor running for ac unit, isi marked, range 36 mfd pl top dfo 440v,50 hz ac as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 pl container lead type make : epcos or similar =01 no. (vii) capacitor a+t starts for ac unit isi marked , range : 80 to 100, , 250v, 50hz ac, container lead type as per is : is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 make : epcos or similar = 01 no. (viii ) capacitor a+t starts for ac unit isi marked , range 100 to 120, , 250v,50hz ac, container lead type as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 make : epcos or similar = 01 no. (ix) capacitor a+t starts for ac unit isi marked , range 120-150, 250v, 50hz ac, container lead type as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 make : epcos or similar = 01 no. items 09 numbers in one set 1. a warranty/guaranty [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of set of electrical maintenance kit. the details of items as follow : (i) heavy duty gi socket dia 50 mm x length : 100 mm as per is : 1239 part 1 2004 suitable for 50 mm gi pipe of bore well pump fittingmake : kirloskar or similar =01 no. (ii) capacitor running range 55+6uf, 6 pin for ac unit isi marked,440v,50hz ac as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 allu. container body make : epcos or similar = 01 no. (iii) capacitor running range 45+6uf, 6 pin for ac unit ,isi marked,440v,50hz ac as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 allu. container body make : epcos or similar =01 no (iv) capacitor running for ac unit isi marked, range 06 mfd pl top dfo 450v,50 hz ac as per is: 2993 part i : 24 or latest / iec 60252-2 : 2010 + amd 1 : 2013pl container lead type make : epcos or similar =01 no. (v) capacitor running for ac unit isi marked, range 10 mfd pl top dfo 440v,50 hz ac as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 pl container lead type make :epcos or similar =01 no. (vi) capacitor running for ac unit, isi marked, range 36 mfd pl top dfo 440v,50 hz ac as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 pl container lead type make : epcos or similar =01 no. (vii) capacitor a+t starts for ac unit isi marked , range : 80 to 100, , 250v, 50hz ac, container lead type as per is : is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 make : epcos or similar = 01 no. (viii ) capacitor a+t starts for ac unit isi marked , range 100 to 120, , 250v,50hz ac, container lead type as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 make : epcos or similar = 01 no. (ix) capacitor a+t starts for ac unit isi marked , range 120-150, 250v, 50hz ac, container lead type as per is: 2993 part i :2024 or latest / iec 60252-2 : 2010 + amd 1 : 2013 make : epcos or similar = 01 no. items 09 numbers in one set 1. a warranty/guaranty [ warranty period: 30 months after the date of delivery ] ]
Tender For purchase of ac material for day to day maintenance of split & window ac's in mdu - capacitor 4 mfd make; epcos/ gc/tibcon, running capacitor aluminium cap 45 mfd make; epcos/gc/tibcon, silver coated copper thimble 32 amp. (100 piece in one packet), pencil valve copper 1/4", refilling of nitrogen gas in existing cylinder provided by the department (capacity of existing cylinder is 7 cubic metre), refilling of oxygen gas in existing cylinder provided by the department (capacity of existing cylinder is 7 cubic metre), lpg can portable gas cartridge, drain pipe pvc flexible (length 6 feet each), ms 25 mm saddle (1"), pvc 25 mm tee (1") make prince, teflon tape make; 3 m, 5 ampere contactor single phase, split ac outdoor stand, fastners for split ac outdoor 8 mm, four core wire 2.5 sqmm make; havells, polycab, rr, plaza, welding rod copper etc....