Web Analytics Made Easy - StatCounter

Photo Film Tenders

Get complete information related to latest Photo Film Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Photo Film Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Photo Film Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40841890 Due date: 25 Jul, 202525 Jul, 2025 NA
Tender For corrigendum : supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100

CTN :41056187 Due date: 02 Aug, 202502 Aug, 2025 38.69 Lacs
Tender For supply of ifa 21 cons d d - dry view film 08 x 10 compatible with konica camera pack of 125 , dry view film 10 x 12compatible with konica camera pack of 125 , high glossy thermal printing paper roll 110 mm x 18 to 20 mtr for printing , inj iodinated radiographic contrast with 60pcent wperv diatrizoate salts in , liquid barium sulphatepermicropaque dispersion 95pcent wperw , semiautomatic core biopsy gun set with 02 throw lengths of 10mm and 20 mm

CTN :40878054 Due date: 25 Jul, 202525 Jul, 2025 NA
Tender For e-tender for supply, installation and commissioning of equipments for the department of microdentistry at muhs regional center, airoli, mumbai - micro endodontic tip kit, common compressor unit, common high vacuum suction unit, rubber dam kit, hand instruments, phosphor plate x ray film with developer (vista scan), apex locators, composite instruments, injectable thermoplastisized gutta percha, operating microscope 5 step magnification, surgical endo kits, sterilizer trays for autoclave, varible intensity vlc units, conventional vlc units, magnifying loupes, composite kits and polishing kits, instrument retrieval kits, pulp tester, ultrasonic cleaner capacity 3.5 liters, camera adaptors (for documentation), dslr camera ( for documentation), phantom head training units for pre-clinical excercises, air rotor high speed handpieces/ air rotor high regular and 45 degree, micromotor hand piece

CTN :41012490 Due date: 18 Jul, 202518 Jul, 2025 16.32 Lacs
Tender For supply of dry view laser films 14x17 compat with 8100 and 8150 kodak camera cartridge 125 films each , inj iohexol 300 mg per ml vial of 50 ml , trimax txe dry view laser imaging film 10x08 in 125 sht compat with printer trimax tx 55 laser imager , trimax txe dry view laser imaging film 12x10 in sht compat with printer trimax tx 55 laser imager , inj gadobenate 0point5 mmol per ml for mri 10ml vial , inj gadobutrol 1point mmol ml of 10ml vial , inj macrocyclic ionic gadolinium based contrast agent for mri 10ml vial

CTN :40221445 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For corrigendum : e-nit for supply/ installation/ commissioning and maintaining of cr systems on 02 year film rental basis (free of cost) and camera/printers for existing mri and ct scan machine (free of cost) with purchase of films on quoted price
 Loading, Please wait...

Connect us via What's Up