Tender For supply of deep freezer , vertical laminar air flow cabinet , orbital shaking incubator , vertical autoclave , minus twenty degree vertical freezer , horizontal gel electrophoresis system , vertical gel electrophoresis system , power pack for electrophoresis , precision weighing machine , microwave oven , micropipettes set , binocular compound microscope , refrigerated centrifuge , double glass water distillation unit , pcr machine gradient , manual total station , handheld gps , ph mv conductivity temperature meter
Tender For supply of electrical and electronics laboratory setup - rlc resonance trainer kit series and parallel resonance, kit consists of voltmeter and frequency counter, inbuilt signal generator, experiments can be performed with or without oscilloscope inbuilt power supply, maximum power transfer theorem trainer kit maximum power transferred from a source to a load when the load resistance is made equal to the internal resistance of a source. inbuilt fixed dc regulated power supplies : 12vdc, meters, ammeter & voltmeter, required components provided, circuit diagram printed on front panel & all important test points are brought out on front panel power requirement : 230 vac, clamp on meter suitable for min 300 a ac/dc current measurement range: 0.2 to 300 a, accuracy 1.5% ac voltage: mv to 1000 vac, accuracy: 0.75% dc voltage: 30mv to 1000 vdc, accuracy: 0.5% resistance: upto 30 mohm, accuracy: 0.5% capacitance 1 nf to 30 micro f, accuracy: 1% frequency upto 100 khz, accuracy: 0.5% auto hold, max/min, auto/manual, diode, ip20 protection., digital meter: portable table top type, with cabinet and stand, terminals brought out for connections, range: voltmeter:0-750v ac 0-500 vdc, ammeter:0-20a ac 0-20a dc 2 nos each range, electronic energy meter( single phase) 240vac, 20aac, electronic energymeter( three phase) 400 vac, 30 aac, digital multimeter ¾ digit , true rms ac voltage range : 1 mv to 1000v, accuracy < 1% dc voltage range : 10 mv - 1000 v, accuracy < 0.5% ac current range : 1 ma-10a, accuracy < 2%, dc current range 0.01 ma-10a, accuracy < 1.5%, resistance: 100 mohm-60 mohms, accuracy < 0.5% input impedance: 10mohm capacitance: 1 nf – 60 mf, accuracy: < 5%, frequency: 0.01 hz – 10 khz, accuracy < 0.1% duty cycle, temperature and diode test, lcd display with auto / manual range , included accessories: test leads, rubber holster, temperature probe, battery charger 12 / 24v dc, 15 a, digital power factor meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: single phase, 220v ac, 5a, digital frequency meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 45-55 hz, digital wattmeter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 220v, 5a ac single phase (2 nos) 400 v, 5a ac, three phase (2 nos), single phase half wave, full wave , fully controlled bridge rectifier / converter design to study to controlled rectifier & observe wave form on cro. meters provided of suitable range, in built power supply. load resistance, controls for phase angle. circuit diagram printed, & test points brought out on front panel. power requirement: 230 vac +10%, 50hz. supplied with patch chords & instruction manual, ups trainer kit input range: 170 to 270 v, ac output (input present): 195 to 250 v capacity: 200 w battery: 12 v / 7 ah, maintenance free, test points for experimentation purpose. panels: input / output / battery / transformer / avr / charger /inverter study of charger study of changeover logic study and working of ups, smps trainer kit input : 110- 230v, output : 12v dc, switching transformer, scr commuation trainer kit two dc regulated power supplies 0-30vdc/150ma & 0-1 vdc/150ma, three meters for voltage & current measurement , scr 2p4m mounted behind the panel, connections of supplies, meters & scr brought out at 4mm sockets., characteristics trainer kit for scr,diac,triac, ujt,igbt instrument comprises of three dc regulated power supplies 0-15 vdc/150ma, 0-50 vdc/150ma & 0-2.5 vdc/150ma, four round dual range meters for voltage & current measurement,ujt, scr, diac, triac & their supportive components mounted behind the panel, connections of supplies, meters & components brought out at 4mm sockets., kit for speed control of dc motor using microcontroller eters (digital) :0-200v dc, 0-500ma dc instrument provided with 1/12 hp dc motor, on board phase a
Tender For corrigendum : tender for supply of clip on type terminal station , auto change over switch 250a , cam type single pole on-off switch 10amps , 1s160 , triple pole moulded case circuit breaker 100amps , hcos 100a for emergency operation(ex.)if envisaged in sotr , illuminated push button green , cam type selector switch 2p 2 way with off 10a , hrc fuse link rated 100a , fuse link 2amps , helo starting cable with nato end connectors (21 meters) , mccb 630a , type lm 630b , make e , 3 pole mccb 32a -nsx100f , mcb 250a with micrologic 2.2 trip unit(lv431770) , tp mccb rated 50a , single pole nine way without off rotary switch rated 16a , contactor 110a t.p.(contact kit) , aux contact.base block ( 1 no+1nc) for 110-a t.p. , fuse 32a fitting hrc , unshourded pushbutton 1no+1nc with yellow colour lens(pmt1ab , illuminated pushbutton integral led 230v red , add on 1no contact , d.p miniature circuit breaker rated 16a , terminal , conventional fire detection panel 4 zones , on delay electronic timer ac 110-240v having range 1-30s , 230v ac relays 4 c/o with led and base alonwith clamp , tp mcb 63a(c60h 3p 63a c) , ammeter 0-1000a , rm-800a , ctr 1000/5a , 96x96 cl1 acc 900 scale , hrc fuse fittings rated 20a (3nw20nnsf) , hrc fuse link rated 6a(3nwns6) , hrc fuse fitting rated 20a (3nwns10) , insulation monitoring relay 115v 3ph 400hz (vtv-02) , ammeter 0-200a ctr 200-5a , 400hz acc cl-1 , 96x96 rm at 150a , kilowatt meter 120-0-750 kw size 96x96mm , frequency meter 55-60-65hz 440v , size 96x96mm rm at 60hz , 1 watt , 24v dc/ac , led bulb , milky white of e27 thread type , 1 watt , 230v ac , led bulb , milky white , of e27 thread type. , breaker 25a , dp mcb , step down transformer 20kva , 380 230v , 3ph , 50 hz star-delta , smoke detector tester gas bottle - solo , main processor unit , navigation lamp 65w 230v (per yard) , under voltage coil 230 , 50/60 hz , hrc fuse fitting with fuse link rated 4amps , hrc fuse fitting with fuse link rated 2a , 3 pole mccb , 100amps , 36ka , schinder make , phase sequence indicator 50-500v , 96x96mm cl1 acc 900 scale , kw mtr 15-0-150kw , ctr 2005/5a , rm at 80kw , 415v , 3p , 2 ele 96mm , generator protection unit415v , 3ph , 50hz , load sharing unit mv av 380v , 50hz , 3ph , ctr 250 5a , m340-discrete outputs-modicon m340 discrete dc output , indicating lamp integral led white colour , 24v ac/dc , indicating lamp integral led green colour , 24v ac/dc , indicating lamp integral led green colour 230v , contactor 800a dc , 28v coil with 1no/1nc aux. contact
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20
Tender For supply of supply of rishabh make meters and transducers d d -1. supply of voltmeter model rish eine nx input - 100- 500 v l-l -programmable-, 3ph 3w by 4w network, accuracy class - 1. 0, , 2. supply of current meter model rish eine nx ,input 1a by 5a -programmable-, 3ph 3w by 4w network, class - 1. 0, , 3. supply of current meter - model rish vdc c with shunt , input - 0 - 75 mv, display - 14 mm led display, accuracy class - 0. 1, , 4. supply of voltmeter model rish eine plus , input - 0-500 v, accuracy class - 0. 5, , aux 2060vdc , 5. supply of ammeter model rish eine plus with shunt, input - 0 - 75mv , 6. supply of powerful dc signal isolator model si101,dc isolator 1 input,1 output, input - 075mv dc , 7. supply of ammeter model rish eine nx input1 by 5a programmable, 1 phase network accuracy class -1 4 digit, , 8. supply of voltmeter model rish eine nx input 57. 8 - 480v l-n programmable, 1 phase network, accuracy class - 1. 0, , 9. supply of voltmeter model rish vdc c input - 0-75mv, display - 14 mm led display , accuracy class 0. 1 , , 1. supply of voltage transducer model tv 808, type dc isolator 1 input-1 output - e8 housing- input 0-400 v dc output - dc voltage - 0-5v , 11. supply of ammeter model rish eine plus input -0-75mv, accuracy class - 0. 5 , aux 40-300vac by dc, without shunt , 12. supply of current transducer model rish con i , input - 1-5a , 13. supply of current transducer model tv 808 ,type - dc signal isolator 1 input-1 output - e8 housing- input - 0-350 v dc, output -dc voltage - 0-5v , 14. supply of current transducer si101, type - dc signal isolator 1 input-1 output input - 0-75mv , output -dc voltage - 0-5v , 15. supply of voltmeter model eq 91, cl 1 , analog voltmeter scale -0-500 v-, 90degree, 96mm x 96mm , 16. supply of voltmeter model eq 91, cl 1 , analog voltmeter scale -0-300 v-, 90degree, 96mm x 96mm , 17. supply of ammeter model eq 91, cl 1. 0 ,ct operated, scale -0-200 a- ctr 200 by 5 amp , 18. supply of ammeter model pq 91 with shunt 150a by 75mv, cl 1. 0 ,90 degree, scale -0-150 a , 19. supply of current meter model vl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-25 a-, ctr, 25 by 5 amp , 20. supply of voltmeter model vl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-500vac- , 21. supply of dc voltmeter meter model pl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-100vdc- , 22. supply of current meter model vl 91 , 23. supply of current meter model vl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-150 a-, ctr, 150 by 5 amp , 24. supply of dc voltmeter meter model pl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-400vdc- , 25. supply of ammeter model rish eine plus with shunt 1200a by 75mv, input - 0 -75mv, , 26. supply of voltmeter model pq 91, input - 4-20ma, size 96mm x 96mm, class 1. 5, 90 degree