Tender For supply of solid state potentiometer , microprocessor based ph meter , electronically controlled magnetic stirrers without heating , electronically controlled magnetic stirrers with heating , digital sonicator system , digital water bath , photoelectriccolorimeter , microprocessor flame photometer , microcontroller based melting boiling point apparatus , laborathory drying oven , cloud pour point apparatus , vaccum pump , analyttical semi micro weighting scale , rotary evaporator , centrifuge , electric water distillation assembly , photocatalytic reactor with specific wavelength of led lights and its accessories , heating mantle 3litre , heating mantle 1litre , heating mantle 500ml , heating mantle 250ml , heating mantle 100ml
Tender For ece lab items dept use - eliminator transformer (step-down) kitinput - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, strain gauge trainer kitmetal foil strain gauge mounted on beam/cantilever strain measurement under applied load wheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltage zero and gain adjustment controlsprovision for applying calibrated loads regulated power supply, 230 v ac, 50 hz table-top trainer with labeled paneltest points to measure the signalsbuilt in power supplies and wooden closed cabinet supplied with patch cords and experiment manual, temperature measurement kitsensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc).display: 3 digit led/lcd digital display (typically 200mv fsd). temperature source: portable water kettle or heater block.signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation.test points: multiple 2mm/4mm banana sockets for monitoring input/output signals.power supply: 230v ac, 50hz, single-phase.accessories: includes a glass thermometer, ntc thermistor probe 10k, k-type thermocouple probe, patch cords, and instruction manual., sim reader trainer kitsim compatibility supports 2g 3g 4g lte sim cards,sim reader mode: reading writing gsm sim card data, imsi, ki codes, phonebook interface usb 2.0 or rs 232 serial port for pc communication.clock frequencies: selectable frequencies 3.579 mhz, 7.159 mhz, 14.318 mhz for sim card operation.power supply: onboard smps 12v 2a or 5v dc with overload protection. hardware components:6-pin or 8 pin sim card socket.led indicators for power, sim reset, and data activity.optional lcd 128x64 and keypad 20 keys for standalone operation. software tools support for at commands gsm etsi 07.0707.05, sim manager utilities, and data logger functionality. common trainer kit featuresfault simulation ability to create faults e.g., sim not detected, vcc failure for troubleshooting.test points: multiple test points e.g., 55 nos for observing signals sim rst, clk, i o via oscilloscope.construction tested glass epoxy pcb, often housed in a study educational case., dual output regulated dc variable power supplydual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, lvdt sensor trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v 500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc, accuracy: class 0.5( 0.5 % full-scale), dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc, accuracy: class 0.5 ( 0.5 % full-scale)
Tender For supply of various items of lab equipments for govt. p g college guna district guna (m.p.) under p m usha pariyojna 4th call - supply of various lab equipments items for govt. p g college guna district guna (m.p.) 4th call, waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectriccolorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr co
Tender For supply of digital ph meter , digital conductivity (ec) meter , microprocessor based potentiometer , digital photoelectriccolorimeter , abbe s refractometer , digital polarimeter with electronic sensor for accuracy and adaptability