Tender For supply, installation, testing and commissioning of on-grid roof top solar photovoltaicpowerplant at gpoa, shastri bhawan additional office building, chennai.
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu
Tender For supply of solar photovoltaicpowerplant , module mounting structure with accessories with pcc foundation complete , battery bank tubular lead acid battery 12v 240ah , power conditioning unit , solar acdb 1 phase 5kva , dcdb 5kw with spd and fuse , mc4 connector , solar dc cable 4mm2 xlpo uv resistant , cable 2c x 10 sqmm copper pvc uv resistant , cable 1c x 16 sqmm aluminum , super chemical earthing kits , lightening arrestor for lightening and over voltage protection , installation kit complete as required for one set of solar power supply 5 kva
Tender For corrigendum : supply, installation, testing and commissioning of 10mw (ac) ground mounted grid connected solar photovoltaicpowerplant with land on lease at any location in gujarat with comprehensive maintenance up to 10 years including free maintenance during first year
Tender For design, survey, manufacture, supply, erection, testing, commissioning of 10 kwp and 5 kwp solar photovoltaicpowerplant at block offices etc. on turn-key basis throughout the state of tripura as per dnie-t
Tender For re-instatement of system at 10mw ground mounted solar photovoltaicpowerplant (spvpp) at ranigunj under paschim bardhaman regional office, wbsedcl
Tender For corrigendum : all- inclusive operation & maintenance of smcs 540 kwp grid-connected rooftop solar photovoltaicpowerplants for 10 years installed at twelve various locations of surat municipal corporation. (5th attempt)
Tender For corrigendum : all- inclusive operation & maintenance of smcs 750 kwp grid-connected rooftop solar photovoltaicpowerplants for 10 years installed at fourteen various locations of surat municipal corporation. (7th attempt)
Tender For corrigendum : supply, installation, testing and commissioning of 620 kwp grid connected rooftop solar photovoltaicpowerplants at various nagar prathmik school with comprehensive maintenance up to 10 years including free maintenance during first year.(2nd attempt)
Tender For providing, supplying and installation of solar and related equipment in kuno wildlife division - off - grid solar photovoltaicpowerplant 1.5 kva, off - grid solar photovoltaicpowerplant 2 kva, off - grid solar photovoltaicpowerplant 3 kva, off - grid solar photovoltaicpowerplant 4 kva, off - grid solar photovoltaicpowerplant 5 kva, off - grid solar photovoltaicpowerplant 7.5 kva (96v), off - grid solar photovoltaicpowerplant 7.5 kva (120v), off - grid solar photovoltaicpowerplant 10 kva, off - grid solar photovoltaicpowerplant 12.5 kva, off - grid solar photovoltaicpowerplant 15 kva, off - grid solar photovoltaicpowerplant 20 kva, off - grid solar photovoltaicpowerplant 30 kva, 1 horse power solar pumping system, 2 horse power solar pumping system, 3 horse power solar pumping system, 5 horse power solar pumping system, 7.5 horse power solar pumping system, 10 horse power solar pumping system, 15 horse power solar pumping system, 20 horse power solar pumping system, 30 horse power solar pumping system, 1 horse power ac single phase submersible motor, 2 horse power ac single phase submersible motor, 3 horse power ac 3-phase submersible motor, 5 horse power ac 3-phase submersible motor, 7.5 horse power ac 3-phase submersible motor, 10 horse power ac 3-phase submersible motor, 12.5 horse power ac 3-phase submersible motor, 15 horse power ac 3-phase submersible motor, 100wp solar panel, 125 wp solar panel, 160 wp solar panel, 335 wp solar panel, 500 wp solar panel, 2kva solar inverter (pcu), 2.5 kva solar inverter (pcu), 5.2 kva solar inverter (pcu) 48v, 5.2 kva solar inverter (pcu) 96v, 10 kva solar inverter (pcu) 96v, 20 ah solar c10 lead acid battery, 40 ah solar c10 lead acid battery, 40 ah solar c10 gel battery, 80 ah solar c10 lead acid battery, 80 ah solar c10 gel battery, 100 ah solar c10 lead acid battery, 100 ah solar c10 gel battery, 150 ah solar c10 lead acid battery, 150 ah solar c10 gel battery, 200 ah solar c10 lead acid battery, 200 ah solar c10 gel battery, 72 ah vehicle lead acid battery for mahindra bolero, 70 ah vehicle lead acid battery for mahindra bolero camper, 72 ah vehicle lead acid battery for mahindra scorpio s11, 74 ah vehicle lead acid battery for mahindra scorpio n, 80 ah vehicle lead acid battery for tata safari, 80 ah vehicle lead acid battery for tata yodha crew cabin 4x4, 80 ah vehicle lead acid battery for force gurkha 4x4, 65 ah vehicle lead acid battery for isuzu d-max v-cross 4x4, 90 ah vehicle lead acid battery for tractors, compatible solar variable frequency drive cum controller with dry run protection for 1 hp solar submersible water pumping sytem with ip65 rated enclosure, compatible solar variable frequency drive cum controller with dry run protection for 2 hp solar submersible water pumping sytem with ip65 rated enclosure, compatible solar variable frequency drive cum controller with dry run protection for 3 hp solar submersible water pumping sytem with ip65 rated enclosure, compatible solar variable frequency drive cum controller with dry run protection for 5 hp solar submersible water pumping sytem with ip65 rated enclosure, compatible solar variable frequency drive cum controller with dry run protection for 7.5 hp solar submersible water pumping sytem with ip65 rated enclosure, compatible solar variable frequency drive cum controller with dry run protection for 10 hp solar submersible water pumping sytem with ip65 rated enclosure, compatible solar variable frequency drive cum controller with dry run protection for 15 hp solar submersible water pumping sytem with ip65 rated enclosure, compatible solar variable frequency drive cum controller with dry run protection for 20 hp solar submersible water pumping sytem with ip65 rated enclosure, compatible solar variable frequency drive cum controller with dry run protection for 30 hp solar submersible water pumping sytem with ip65 rated enclosure, price per visit for maintenance of existing solar installations includi