Get complete information related to latest Photovoltaic Module Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Photovoltaic Module Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Photovoltaic Module Tenders.
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For corrigendum : supply of multimeter digital , megger , hydrometer , solar insulation meter , pyranometer , pyrheliometer , lux meter , magnetic flux meter , tong tester clamp meter , soldering iron , temperature controlled soldering iron , thermometer digital , sunshine recorder , weather monitoring station , solar cell - based sunlight radiation meter , solar simulator for solar cell characteristic study , iv curve tester , sun path finder , solar energy trainer with grouping of solar cells , solar tracker demonstrator kit , solar pv e learning module using animations for learning and training , motorized bench grinder , solar photovoltaicmodule , solar panels , solar charge controller with dusk to dawn automatic switching , solar charge controller with manual switch day lighting , array junction box , home light system , anemometer , dc table fan , ac voltmeter mi , voltmeter , ammeter mc , ammeter mc centre zero , power factor meter , rheostat , ac energy meter , kilo wattmeter analog , digital wattmeter , phase sequence indicator , frequency meter , dc led lamp , dc pump , pwm controller , mppt charge controller , inverter with battery , solar pcu , solar grid tied inverter demonstrator training kit . , solar street light , solar wind and hybrid power plant , solar traffic light , used water treatment solar plant demonstrator kit , solar dc pump , demonstration kit for wind generation ) /bid number : gem/2026/b/7490187 * /dated: 04-05-2026 & & / bid document 1 / 46
Tender For design, supply, installation, testing, and commissioning (dsitc) of the following renewable energy and community infrastructure systems under its climate-resilient sundar shakti initiatives in west bengal. - solar microgrid system solar irrigation system solar cold storage system solar-powered packaged drinking water unit -
Tender For corrigendum : providing of hiring of consultants - milestone/deliverable based - appointment of independent engineer for transmission system for evacuation of power from potential renewable energy zone in khavda area of gujarat under phase v (8gw) part c; energy (oil, gas, pow..
Tender For supply of solar insulation meter , pyranometer , pyrheliometer , lux meter lux meter lcd read out 005 to 7000 lumens with battery , magnetic flux meter 0500 tesla , tong tester clamp meter 0 100 a digital type , soldering iron set 25 watt 65 watt and 120 watt 230 volt set of 3 , temperature controlled soldering iron 50 watt 230 volt , thermometer digital 0 degree c 150 degree c , sun shine recorder , weather monitoring station to monitor and record unshine wind velocity temperature rainfall etc with software , solar cell based sunlight radiation meter for solar power measurement up to 2000 wsquare meter , magnetic compass , cut models of photo voltaic cell assembly , model of lead acid battery , lead acid battery set 12v 40ah 75ah , lead acid battery 12v 100 ah , solar simulator for solar cell characteristic study to study iv curve of a solar cell of minimum 2 watt under variable illumination temperature and suitable load , iv curve tester , sun path finder , solar energy trainer with grouping of solar cells to group series or parallel at least six solar cells each with minimum 2 w with suitable loads , solar tracker demonstrator kit to study manual and automatic control of 10 w solar panel in east west and northsouth andback , halogen lamp set with stand for illumination of solar panels in lab ac mains operated to provide 0 to 1000 watts per meter square , pedestal grinder double ended 300 mm , battery charger 0 6 9 12 24 48 v 30amp , solar photovoltaicmodule 10 w poly crystalline module , solar photovoltaicmodule 250 w , solar photovoltaicmodule 250 w thin film module , solar photovoltaicmodule 40 w poly crystalline module , solar photovoltaicmodule 5 w poly crystalline module , solar photovoltaicmodule 75 w amorphous silicon module , solar photovoltaicmodule 75 w mono crystalline module , solar panels 250 wp , solar charge controller with dusk to dawn automatic switching 12v 10a , solar charge controller with manual switch day lighting 12 v 10 a , array junction box for connecting 250w x 4 nos solar panel with dc fuse dc mcb and surge suppressor protection , solar lantern led type , solar lantern cfl type , solar lantern assembly sets , home light system 12 v dc with fm receiver led bulb and mobile charger as loads , solar cell kit , clinometer for angle measurement , spirit level for floor level check , anemometer for wind speed measurement , dc table fan 12 v , ac voltmeter mi 0 , providing and supplying of volt meter 0 30v , volt meter 0 100v , ammeter mc 0 1a , ammeter mc 0 5a , ammeter mc centre zero 0 20a , ammeter mc centre zero 050a , power factor meter , rheostat set 0 1 ohm 5 amp 0 10 ohm 5 amp 0 25 ohm 1 amp 0 300 ohm 1 amp set , ac energy meter single phase 10 a 240 v inductiontype , ac energy meter three phase 15 a 440 v induction type , kilo wattmeter analog , digital wattmeter 230 v 1 kw 50 hz , phase sequence indicator 3 phase 415 v , frequency meter 45 to 55 hz , dc led lamp set 3w 5w 10w set of 3 , dc pump 24 v , pwm controller , mppt charge controller , solar grid tied inverter demonstrator kit 300w kw
Tender For tender for procurement of renewable energy power from its upcoming 100 mw solar pv project with 50 mw/200 mwh battery energy storage system (bess) in the state of u.p.
Tender For corrigendum : design, development and implementation of a single window clearance system portal along with 5 years of operation & maintenance, for bihar renewable energy development agency