Web Analytics Made Easy - StatCounter

Pipe Fitting Tenders

Get complete information related to latest Pipe Fitting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pipe Fitting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pipe Fitting Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45683013 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply of nylon rope ladder complete with 1" dia. aluminum steps as per design. nylon rope of 25 mm dia. with steps of 25 mm dia. aluminum alloy corrugated tubing spaced at 12 c/c duly packed on both sides size 20 feet long with hook for hanging. specification as per attached annexure "a". [ warrantyperiod: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45731339 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of flexible flame-retardant, high performance,polyolefin heat srinkable tubing, as per drawing: edml176, rev. '0', packing instruction: pi042 ver 3.0 (1) drawing no. icf/j&t/misc-2487 alt. `b? to be followed. (2) it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage, if any, shall be at the cost of supplier. for underframes: both (1) & (2) to be followed as stated above. for other items except underframes: only (2) need to followed. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45731350 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of set of pipe fittings for co-co bogie piping (wag-9hc & wap-7) to set list el29230524 rev."1 " & spec no. clw/ms/3/053 alt.21 with latest alteration & str no. clw/2018/eldo/m/str/050 dt. feb. 2019 rev 0 with latest. drg. no./spec.:- clw's spec no. clw/ms/3/053 alt.21 with latest & str no. clw/2018/eldo/m/str/050 dt. feb. 2019 rev 0 with latest. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45438754 Due date: 20 Aug, 202620 Aug, 2026 NA
Tender For corrigendum : supply of pipe & with pipe fitting air brake equipment suitable for boxn hl wagon as perdrg.no. wd-05086-s-11 alt-2 and rdso specification no-04-abr-2019 (rev.02 of dec-2019) [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45743884 Due date: 20 Aug, 202620 Aug, 2026 NA
Tender For supply of pipe & with pipe fitting air brake equipment suitable for boxn hl wagon as perdrg.no. wd-05086-s-11 alt-2 and rdso specification no-04-abr-2019 (rev.02 of dec-2019) [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45736219 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For supply of opo 85 multiple- use (reusable, sterile) phaco tubing for compact intuitive phaco-emulsification system [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :44883821 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For corrigendum : supply of tubes and work of insitu retubing as per atc d d - aluminium brass seamless cold drawn tubes , end plate having size of o.d. 267mm, thickness 16.5mm, 190nos. of holes and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 205mm, thickness 32mm, 190nos. of holes and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 330mm, thickness 25mm, 320nos. of holes and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 260mm, thickness 40mm, 320nos. of holes and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , baffles having size of o.d. 205mm, thickness 04mm both end chamfer and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 25nos. , baffles having size of o.d. 260mm, thickness 04mm both end chamfer and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 19nos. , work of complete in situ re tubing of old damaged tube cooler of lube oil cooler of 210mw unit no. 3 and 4 as per atc , work of complete in situ re tubing of old damaged tube cooler of working oil cooler of 210mw unit no. 3 and 4 as per atc ) /bid number : gem/2026/b/7336822 * /dated: 14-04-2026 & & / bid document 1 / 12

State Government

CTN :45739217 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of abb make ph sensor , abb make ph analyzer , abb make conductivity analyzer , conductivity sensor , annual spares kit , tubing kit exc pump tubes , power supply board panel mount ac

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government/Public Sector

CTN :45491045 Due date: 07 Jul, 202607 Jul, 2026 45.00 Lacs
Tender For corrigendum : repair to water proofing treatment for rcc roof and repair to chajja parapet water tank gi tubing and rain water pipe in domestic area at af stn nal under ge af nal
 Loading, Please wait...

Connect us via What's Up