Get complete information related to latest Pipeline Lifting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pipeline Lifting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pipeline Lifting Tenders.
Tender For amrut-2.0 - cherpulasseri-gap filling and extra work for laying 90mm pvc pipe, excavation work for laying 450mm di pipe (prohibited blasting) and gi, ms , road restoration work (lsgd) at cherpulasseri municipality
Tender For corrigendum : supply and installation of electrical fixtures and gadgets in bolpur ib at bolpur under burdwan zone in west bengal. - supply & delivery of 3 phase 415v fixed speed cassette type air-conditioner machine having cooling capacity not less than 14100w, eer 2.7 to 3.2, noise level not more than 56db. this cassette type air conditioning machine should be fitted with scroll compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (make-o-general /mitsubishi electric/mitshubishi heavy industries as per approved by eic/authority)., supply & delivery of 240v split air-conditioner machine having cooling capacity not less than 6875 w, isser 3.8 to 4.39, bee rating not less than 3 star, noise level not more than 46db. this split air conditioning machine should be fitted with rotary compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (o-general /mitsubishi electric /mitshubishi heavy industries as per approved by eic/authority)., installation, testing & commissioning of the above-said split ac outdoor unit on existing iron structure and indoor unit on wall & mending good the damages as per direction of e.i.c., installation, testing & commissioning of the above-said split ac outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of e.i.c., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 3/8"(for discharge) 1.15mm thickness copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 1/2"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & laying of 4core 2.5sq.mm 1.1 kv insulation grade sheathed cu cable with gas line as per direction of eic for making interconnection/communication between indoor to outdoor unit of split type ac m/c.(make- havells/finolex/polycab as approved by e.i.c), supply and laying 5/8(20mm) heavy type pvc pipe for water drainage., supplying, fabrication & fixing of iron stand of m.s. angle size (40 mm x 40mmx6mm) for installation of outdoor unit of 4.0 tr split ac incl. drilling 2 nos holes in each angle and horizontal angle angle 40 mm x40mm x 6 mm in each stand. each stand will be properly fixing by supporting angle (25x25x5mm) and flushnut on peripheral wall as per machine configuration & load with adequate service access as per direction of eic, supplying and fixing 415 v four pole mccb of breaking capacity 25ka/35ka with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing dbs / enclosure and necessary connection (a) 160 amp fp mccb (make legrand/crabtree/siemens/l&t/ abb as approved by e.i.c) [d-8/10], supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection (make legrand/crabtree/siemens/l&t/abb as approved by e.i.c) [d-6/7] (a) 6-32 amp tp mcb, distribution wiring in 1.1 kv single core stranded fr pvc insulated & unsheathed copper wire (brand approved by eic) in 20mm size pvc rigid conduit fr (precision make) incl. necy. fittings as required[e-14] i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ecc [e-14/ 1(a)(iii)], s & f 3phase 9-15a , 415 v dol starter (make-l & t ,cat no. ss94351 or equivalent model of abb/siemens as per dierction of e.i.c) to be fixed on wall with all fixing accessories complete as
Tender For supply of supply of networking item - 1 inch hdpe pipe , supply of 12 core multimode outdoor armoured fiber , supply of 24 core multimode outdoor armoured fiber , supply of fully loaded liu pigtails , supply of jpu fully loaded , 24 port cat 6 utp jackpanel , supply of cat 6 single information outlets with backbox and shuttered face plate commscope , supply of cat 6 dual information outlets with backbox and shuttered face plate commscope , supply of cat 6 shield metal field keystone jack commscope amp molex systimax panduit , supply of cat 6 shield metal field rj45 plug commscope amp molex systimax panduit , supply of cat 6 utp patch cord 1 meter red green commscope amp molex systimax panduit , supply of cat 6 utp patch cord 2 meter red green commscope amp molex systimax panduit , supply of cat 6 utp patch cord 3 meter red green commscope amp molex systimax panduit , supply of modular concealed gi metal box , supply of 1 inch pvc flexible pipe with accessories , supply of 1.5 inch pvc flexible pipe with accessories , supply of 2 inch pvc flexible pipe with accessories , supply of cat 6 utp cale box 305 meter commscope amp molex systimax panduit , supply of 1 inch conduit pipe , supply of 1.5 inch conduit pipe , supply of 1 inch casing and cappinng , supply of 1.5 inch casing and cappinng , supply of 2 inch casing and cappinng , supply of 2 inch gi pipe , supply of 1 inch ms pipe , supply of 6 2 inch raceway casing white , supply of 4 2 inch pvc casing white , supply of 2 2 inch pvc casing white , supply of 9 u wall rack with pdu and accessories , supply of 15 u wall rack with pdu and accessories , supply of 27 u floor mounting rack 800x800 with pdu and accessories , ofc laying with hdpe pipe with digging soft soil and refilling 3 feet x 1 feet approx , ofc laying with hdpe pipe with clamping required material clamping nail etc .should be provided by the vendor 3 feet x 1 feet approx , ofc laying with hdpe pipe through hdd , consruction supply and installation of cement chambers with covers 2.5ftx2.5ftx2.5ft , supply and fixing of ofc route markers stone , installation of liu , splicing and testing of pigtails , installation of utp jack pannel , laying of utp cable per meter , groove cutting in walls floors and fixing pvc 1 1.5 inch pipes , groove cutting in walls floors and fixing of modular concealated gi metal box metal box covering them , termination of i o box and fixing of face plate , laying of 1in conduit pipe required material screw gatta bend collar junction box should be provided by the vendor , laying of 1.5in conduit pipe required material screw gatta bend collar junction box should be provided by the vendor , laying of 1 incasing and cappinng required material screw gatta bend collar junction box should be provided by the vendor , laying of 1.5in casing and capping required material screw gatta bend collar junction box should be provided by the vendor , laying of 2in casing and capping required material screw gatta bend collar junction box should be provided by the vendor , laying of 2in gi pipe required material screw gatta bend collar junction box should be provided by the vendor , laying of 6 2 in pvc casing required material screw gatta bend collar junction box should be provided by the vendor , laying of 4 2 in pvc casing required material screw gatta bend collar junction box should be provided by the vendor , laying of 2 2 in pvc casing required material screw gatta bend collar junction box should be provided by the vendor , ofc outdoor 12core splicing kit with necessary consumables and enclosure , ofc otdr test per core bid details/ 2 / 43 charges with report , network and server support deploying of 5 service engineers
Tender For corrigendum : prov. house connection for existing and new pipe line prov. laying jointing testing pvc pipe specials sluice valve chamber chlorinator replacement of control panel repair of pump chamber ohsr and all other works complete in all respect
Tender For corrigendum : prov. house connection for existing and new pipe line prov. laying jointing testing pvc pipe specials sluice valve chamber chlorinator replacement of control panel repair of pump chamber ohsr and all other works complete in all respect.
Tender For laying of 110mm dia pvc pipe lines 6kg/cm2 for interconnecting bores from nlf school & gajjalakunta to ramarao colony sump in 4th ward in madanapalle municipality
Tender For laying of 110mm dia pvc pipe lines 6kg/cm2 at 3/169-13-64-6-d to 3/169-b-64-6-a and from ragimanu to 3-146-14-12-23-d (weavers colony end) & ragimanu to mujeeb nagar sachivalayam down at ramarao colony-3rd ward in madanapalle municipality