Get complete information related to latest Pipeline Relaying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pipeline Relaying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pipeline Relaying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :39419359 Due date: 07 Jun, 202507 Jun, 2025 27.80 Lacs
Tender For bid to ras supply of supply of 1.5 tr inverter type 5 star rated split air- conditioner unit , dismantling of existing 1.5 tr split ac unit , installation, testing and commissioning of the split ac unit , supplying and fixing extra copper pipe line , supplying and laying 4 core 2.5 sq. mm pvc insulated and pvc sheathed flexible copper cable , supplying and fixing of powder coated ms frame stand , supplying and fixing of 20 mm dia heavy duty pvc pipe with accessories for drain water connection

Central Government And Public Sector

CTN :40343835 Due date: 06 Jun, 202506 Jun, 2025 5.14 Lacs
Tender For corrigendum : supply of call base repair of ems at telephone bhavan - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair

CTN :40580779 Due date: 24 Jun, 202524 Jun, 2025 NA
Tender For supply of removing of 2 ft x 2 ft false ceiling sheets distempering and refixing of the same are 44 sqft x 48 sqft , wall painting providing touch up putty and two coats of asian tractor distemper , aluminium and glass 03 track sliding window size 04 ft x 04 ft x 04 nos , aluminium glass door 07 ft x 04 ft , installation of door entry size 7 ft x 4 ft alongwith glass gate , repair and polishing of bar counter and wall skirting tiles , 25 sqmm 4 core ug cabe universal or polycalbe , 2 ton pillar ac voltas , deep freezer blue star 500 ltr , 2 ft x 2 ft ceiling lights led , led flood light 04 ft and 50 watts orbit , ceiling fan 1200 mm sweep cromption or bajaj or usha , outdoor panel box with mcb , electric wiring using copper wire 04 sqmm and 2.5 sqmm and 1.5 sqmm with pvc pipe and switch control for light points 24 nos fan point 14 nos and 15 amps 04 nos and 5 amps 04 nos , laying of ug cable , electrician labour charges

Central Government And Public Sector

CTN :40568820 Due date: 23 Jun, 202523 Jun, 2025 NA
Tender For corrigendum : supply of supply of high precision air conditioners bsnl - 7tr hpac units , itc package ac unit and condensers , providing and fixing 40mm dia cpvs pipe , sitc of 15.86 mm dia od refrigerant pipe , sitc of 22.2 mm dia od refrigerant pipe , sitc of gi 150x50 mm depth x 1.6 mm thickness , sitc of gi 300x50 mm depth x 1.6 mm thickness , supplying and laying of 1.1 kv grade xlpe copper conductor , cm of 7tr hpac pkg units for a period of one year

Central Government/Public Sector

CTN :40330612 Due date: 11 Jun, 202511 Jun, 2025 37.97 Lacs
Tender For corrigendum : tender for supply of supply of bakelite sheet with 1nos of 6a dp mcb and stud type connector suitable for 4cx 6sq mm cable complete as required. , supply of 25w led street light luminiare with pre die cast aluminium housing and ip 66 protection , pf greater than equal to 0.95 , thd less than 10 percent , cri greater than equal to 70 as per technical specification complete as required. , supply of lt power cable of 1.1 kv grade of following sizes aluminium conductor xlpe insulated pvc sheathed armoured cable confirming to is 7098 part-i-1988 with upto date ammendment as required. a) 3.5 c x 95 sq. mm , supply of lt power cable of 1.1 kv grade of following sizes 4c x 6sq.mm(copper conductor) , supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket , bend , couplers etc. conforming to is 14930 , part ii complete with fitting and cutting , jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. a) 63 mm dia (od-63 mm & id-50 mm nominal) , laying of one number pvc insulated and pvc sheathed/xlpe power cable of 1.1kv grade of following size in the existing rcc/gi/hume/metal/hdpe pipe etc. as required. a) above 35sq.mm and up to 95 sq mm , laying of one number pvc insulated and pvc sheathed/xlpe power cable of 1.1kv grade of following size in the existing rcc/gi/hume/metal/hdpe pipe etc. as required. b) up to 35 sq mm , supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. a) 3.5c x 95 sq.mm , supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. b) 4c x 6sq.mm(copper conductor) , itc of gi octagonal pole of following length in reinforced cement concrete 1 ratio 2 ratio 4 (1 cement 2 coarse sand 4 stone aggregate 40mm nominal size) foundation i/c excavation and refilling etc. complete as required a) 5 mtr. height , itc of 30w led street light luminiare on existing pole bracket i/c connection with 1.5sq.mm frls copper wire complete as required. , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. , providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut , bolt , spring , washer excavation and re-filling etc. as required. , earthing with g.i. earth pipe 4.5 metre long , 40 mm dia including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. , providing and laying earth connections , from earth electrode with 6 swg dia , g.i wire in 15mm dia , g.i pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. , providing and fixing 6 swg g.i. wire on surface or in recess for loop earthing alongwith the existing cable as required. , design , fabrication , supply , installation , testing & commissioning of outdoor feeder pillar , cubicle type , made out of 2 mm thick crca sheet , totally enclosed , ip 55 , free standing , floor mounting , dust and vermin proof , indoor , compartmentalised , suitable for operation on 3 phase and neutral , 415 v , 50 hz ac system , including internal wiring with suitable size wires/cable , interconnection , duly powder coated painting etc. , including supply & installation of following switchgears , metering instruments and accessories in the feeder pillar as required as per attached boq in atc , shifting of 5 mtr height str

Central Government And Public Sector

CTN :40568363 Due date: 13 Jun, 202513 Jun, 2025 NA
Tender For supply of supply of 3tr copper coil evaporator and copper coil condenser ductable ac units , installation testing and commissioning of 3 tr ductable air conditioning units , supplying and laying of copper refrigerant pipes for 3 tr ductable ac units , extra for supply and charging of additional refrigerant gas , providing indoor and outdoor unit mounting bracket system , supplying and laying of 2.5sq.mm 4 core pvc or xlpe insulated and pvc sheathed copper conductor unarmoured cable , supplying and installing 300 mm width x 50 mm depth x 1.6 mm thickness size perforated painted with powder coating m.s. cable trays , providing and laying of 40mm dia fire retardant corrosion free medium class u pvc pipe along with accessories , providing and laying of 32mm dia fire retardant corrosion free medium class u pvc pipe along with accessories , providing and laying of 25mm dia fire retardant corrosion free medium class u pvc pipe along with accessories , supply fabrication and installation of 22 swg gi sheet plenum duct complete with all accessories , supply and fixing of rectangular fire retardant canvas duct connector having fabric section vinyl coated woven nylon or polyester blend material , supplying and fixing of powder coated extruded aluminium supply air grills with fixed front louvers

CTN :40195442 Due date: 04 Jun, 202504 Jun, 2025 NA
Tender For bid to ras supply of xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) (q2) , mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2) , supply install testing commissioning of step down transformer indoor type voltage rating ht11 bye zero point 433 kv out door type of capacity 200 kva level 2 3 phase 4 wire 50 hz , supply laying and testing 11 kv earthed grades cable xlpe 120 sqmm 3 core , s and f cable end jointing kit for 11 kv grade cable for outdoor termination heat shrink type cable end complete with jointing material and accessories , s and f cable end jointing kit for 11 kv grade cable for outdoor termination heat shrink type cable end , material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40 mm graded stone aggregate for making good cutting portion mass concrete , m and l for pcc 1 ratio 3 ratio 6 type c2 using 40 mm graded stone aggregate for making good cutting portion mass concrete filling of foundations etc including necessary use and waste of form work , supply and fix tpn distribution board 4 way acrylic door 415 volts ac tpn for flush mounting with 100 amps double door copper busbar neutral bar earth bar and mcb incomer of rating upto 100amps , material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directely in ground vertically , supply install testing and commissioning of lt feeder panel of size 1500 x 1500 x 600 mm 3 phase 4 wire 415 v 50 hz ac outdoor type , m and l for brick sub class b 250x115x75 mm and laid in trenches as in protection of ug cable , supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed , removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1 point 5 mtr above the starting point all as specified and directed , m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed , boaring holes horizontally under road without damaging the surface of road minimum1pointzero mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable , supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed

CTN :40563359 Due date: 05 Jun, 202505 Jun, 2025 5.77 Crore
Tender For state scheme (nabard)/25-26/jhanjharpur/01 - 1) construction of hl rcc bridge in karhara to malleh road over bhutia balan river-ch-2.10 km, earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. upto 3.000 m depth, providing and constructing temporary island 16 m diameter. all complete job as per specifications and direction of e/i., providing service road etc. all complete job as per specifications and direction of e/i., providing steel liner 6 mm thick for piles including fabricating and setting out as per detailed drawing., bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., dismantling of reinforced concrete pile head complete as per drawing and technical specification, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., cement concrete for reinforced concrete m - 35 in pile cap complete as per drawing and technical specification, supplying, fitting and placing un-coated hysd bar reinforcement in foundation complete as per drawing and technical specifications., providing rcc m-30 mechanically mixed concrete in sub structure with stone aggregate 20 mm nominal size and clean coarse sand of fm-2 all complete job as per design upto 5 m hieght, supply fitting & fixing elasto-meric bearing & seismic pad :-- supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weep holes in abutment cap with 100mm dia ac pipe:-- providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications., supplying, fitting and placing hysd bar reinforcement in substructure complete as per drawing and technical specification., back filling behind abutment, wing wall and return wall, complete as per drawing and \technical specification.(sandy material ), providing and laying of filter media with granular materials/stone crushed aggregate satisfying the requirement laid down in ci. 2504.22 of morth specification of not less than 600mm behind abutment, wing and return wall to the full height compacted., providing rcc m 30 grade & super structure :-- furnishing and placing reinforced/ prestressed cement concrete in super-structure as per drawing and technical specification beyond 5 m and upto 10m hieght (t beam slab), providing hysd bar in all types of rcc work:-- supplying, fitting and placing hysd bar reinforcement in super-structure complete as per drawing and technical specifications ., wearing coat :-- providing and laying cement concrete wearing coat m-30 grade including reinforcement complete as per drawing and technical specifications, providing rcc m30 grade in railing:-- construction of precast rcc railing of m30 grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications., providing drainage spout:-- drainage spouts complete as per drawing and technical specification, providing pcc m15 grade below approach slab:-- pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, providing pcc / rcc m30 in approach slab:-- reinforced cement concrete approach slab including

CTN :40563360 Due date: 05 Jun, 202505 Jun, 2025 8.02 Crore
Tender For state scheme(nabard)/25-26/kishanganj-2/02 - construction of rcc h.l. bridge in t05 to raipur to jharkhuda path (mmgsy) ch-0.030 km, h.l. bridge work, foundation, excavation for structures, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material., i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification., pile cap in rcc m-30 (using batching plant, transit mixer and concrete pump), bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., ii. 1200 mm dia (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing temporary earth island (assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth, providing and constructing one span service road to reach island location from one pier location to another pier location including royality for earth, carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load, a) initial load test on test pile for 2.5 times the design load specified in drawings, 1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specification, i) upto 5m height (using batching plant, transit mixer and concrete pump), ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), r.c.c. grade m-35 in substructure complete as per dwg & tech specification, ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8, i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinfo

CTN :40563358 Due date: 05 Jun, 202505 Jun, 2025 7.15 Crore
Tender For state scheme(nabard)/25-26/kishanganj-2/01 - construction of rcc h.l. bridge in malgachh to lat at ch.-0.600 km., h.l. bridge work, foundation, excavation for structures, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material., i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification., pile cap in rcc m-30 (using batching plant, transit mixer and concrete pump), bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., ii. 1200 mm dia (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load, a) initial load test on test pile for 2.5 times the design load specified in drawings, 1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specification, i) upto 5m height (using batching plant, transit mixer and concrete pump), ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), r.c.c. grade m-35 in substructure complete as per dwg & tech specification, ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8, i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5, ii. rcc m-30 (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in superstructrue complete as per drawings and technical sp