Get complete information related to latest Piping Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Piping Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Piping Tenders.
Tender For supply of ac system of display hall c c -air diffusersorgrill with powder coated aluminium refer annexure iii , 100000000013 supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure iii , 100000000014 supply of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iii , 100000000015 supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure iii , 100000000016 supply of control instruments and sensors required for combined fire and smoke damper including actuators refer annexure iii , 100000000017 supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper made of aluminium refer annexure iii , 100000000018 supply of floor mounted cubicle non drawout electrical control panel for operating 3 nos ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure iii , 100000000019 supply of following size lt power cable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc outer sheathed refer annexure iii , 100000000020 supply of xlpe insulated pvc sheathed armoured copper conductor 2xfy, 1. 1 kv grade lt cable of size 4. 0 core - 2. 5 sqmm refer annexure iii , 100000000021 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1. 6 mm thickness refer annexure iii , 100000000022 installation testing and commissioning of high static pressure ductable ac unit capacity not less than 16. 5 tr having one indoor and refer annexure iv , 100000000023 erection testing and commissioning of high wall mount type hot and cold split ac units of cooling capacity not less than 2. 0 tr minimum 3 star rating inverter refer annexure iv , 100000000024 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac refer annexure iv , 100000000025 erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split ac refer annexure iv , 100000000026 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure iv , 100000000027 laying of cpvc sdr11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000028 laying of cpvc sdr11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000029 fabrication installation testing and commissioning of site fabricated gi sheet metal ducts of 24 guage birmingham gauge refer annexure iv , 100000000030 fabrication, installation, testing and commissioning of site fabricated gi sheet metal ducts of 22 guage birmingham gauge refer annexure iv , 100000000031 fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber class o refer annexure iv , 100000000032 fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure iv , 100000000033 erection testing and commissioning of volume control dampers for ducts made of gi sheet of thickness not less than 18 g including fittings refer annexure iv , 100000000034 fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer //bid details2 / 31annexure iv , 100000000035 fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure iv , 100000000036 erection testing and commissioning of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iv , 100000000037 fxing testing and commissioning of fire damp
Tender For providing of custom bid for services - 9070c26a43 supply and application of frp lining, piping, and ducting jobs at paradip refinery, paradip, odisha
Tender For providing of custom bid for services - 9030c26a50 annual rate contract line up for ultrasonic thickness gauging of equipment and piping at oxoacrylic acid plant at dumad
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - petroleum refinery; mrpl tender no 3900002017 for piping and structural fabrication work as per sow and boq and in gem overall total lump sum rate to be quoted consideri..
Tender For corrigendum : providing of custom bid for services - 9060c26a08 rprc264012- rate contract for provision of corrosion protection pads at pipe support locations for piping works at panipat refinery & petrochemical complex
Tender For corrigendum : supply of supply of piping spools cs ss and as : : -group no. g001 as per mr , supply of group no. g002 as per mr , transportation of group no. g001 as per mr , transportation of group no. g002 as per mr , manmonth rate for supervision of group no. g001 as per mr , man-month rate for supervision of group no. g002 as per mr
Tender For bid to ras supply of c73340100470 supply of cassette ac four way of 2tr capacity, minimum 5 star rating inverter type refer annexure iii , c73340000754 supply of split ac of 2tr capacity, minimum 5 star rating inverter type rotary or scroll compressor refer annexure iii , c73340001239 supply of window ac of 1.5tr capacity, minimum 5 star rating inverter type rotary or scroll compressor refer annexure iii , 100000000000 supply of refrigerant grade copper piping between indoor and outdoor units of suitable size refer annexure iii , 100000000001 supply of 4 core 2point5 sqmm flexible copper power cable with all fittings refer annexure iii , 100000000002 supply of cpvc sdr11 pipes of 25 mm dia with 9mm nitrial insulation refer annexure iii , 100000000003 supply of cpvc sdr11 pipes of 32 mm dia with 9mm nitrial insulation refer annexure iii , 100000000004 supply of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes refer annexure iii , 100000000005 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure iii , 100000000006 installation,testing and commissioning of cassette ac four way of 2tr capacity, minimum 5 star refer annexure iv , 100000000007 installation,testing and commissioning of split ac of 2tr capacity, minimum 5 star rating inverter type rotary refer annexure iv , 100000000008 installation,testing and commissioning of window ac of 1point5tr refer annexure iv , 100000000009 erection, testing and commissioning of refrigerant grade copper piping between indoor and outdoor units of suitable size refer annexure iv , 100000000010 laying of 4 core 2point5 sqmm flexible copper power cable with all fittings refer annexure iv , 100000000011 laying of cpvc sdr11 pipes of 25 mm dia with 9mm nitrial insulation refer annexure iv , 100000000012 laying of cpvc sdr11 pipes of 32 mm dia with 9mm nitrial insulation, for condensate water drain refer annexure iv , 100000000013 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm refer annexure iv , 100000000014 installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1oint6 mm thickness refer annexure iv , 100000000015 dismantling and shifting of existing split,cassette and window ac total 21nos refer annexure iv