Get complete information related to latest Piping Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Piping Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Piping Tenders.
Tender For motor and pump maintenance along with material supply for bhor municipal council - rewinding of different capacity motors, 90 h.p, 60 h.p, 50 h.p, 25 h.p, 12.5 h.p, 10 h.p, 7.5 h.p, 5 h.p, 2 h.p, supply of bearing no. 6318, supply of bearing no.7322, supply of bearing no. 6316, supply of bearing no.7320.13, motor dismantling and repairingand erection, 90 h.p, 60 h.p, 50 h.p, 25 h.p, 12.5 h.p, 10 h.p, 7.5 h.p, 5 h.p, 2 h.p, repairing of 90 hp v.t. pumps -dismantling and repairing and erection of following capacity v.t. pumps with bowl assembly , column pipe ,shaft, bearing ,bushing as par sapplied including all cost of skilled labour, transportation, loading unloading and all applicable taxes (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote), repairing of 60 hp v.t. pumps -dismantling and repairing and erection of following capacity v.t. pumps with bowl assembly , column pipe ,shaft, bearing ,bushing as par sapplied including all cost of skilled labour, transportation, loading unloading and all applicable taxes (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote), supply of various parts for 90 h.p pump stuffing box bronze bushing., supply of various parts for 90 h.p pump gland sleeve s/s material., supply of various parts for 90 h.p pump top bowl repair with providing and welding of m.s. flange heavy duty with required sundry etc., supply of various parts for 90 h.p pump column pipe repair with welding if ribs m.s. flange with machining etc., supply of various parts for 90 h.p pump rubber bush, supply of various parts for 90 h.p pump shaft sleeve s/s material, supply of various parts for 90 h.p pump providing and fixing special strengthening heavy duty nut bolts., supply of various parts for 90 h.p pump rubber packing (chanmpion), supply of various parts for 90 h.p pump neck ring brass., supply of various parts for 90 h.p pump bowl bush rubber., supply of various parts for 90 h.p pump bowl bush brass., supply of various parts for 90 h.p pump impeller., supply of various parts for 90 h.p pump impeller turning, supply of various parts for 90 h.p pump spider bushing, supply of various parts for 90 h.p pump bowl assembly fitting, tafflon gland, supply of various parts for 60 h.p pump stuffing box bronze bushing., supply of various parts for 60 h.p pump gland sleeve s/s material., supply of various parts for 60 h.p pump top bowl repair with providing and welding of m.s. flange heavy duty with required sundry etc., supply of various parts for 60 h.p pump rubber bush, supply of various parts for 60 h.p pump shaft sleeve s/s material, supply of various parts for 60 h.p pump providing and fixing special strengthening heavy duty nut bolts., supply of various parts for 60 h.p pump rubber packing (chanmpion), supply of various parts for 60 h.p pump neck ring brass., supply of various parts for 60 h.p pump bowl bush rubber., supply of various parts for 60 h.p pump bowl bush brass., supply of various parts for 60 h.p pump impeller., supply of various parts for 60 h.p pump impeller qualate., supply of various parts for 60 h.p pump spider bushing, supply of various parts for 60 h.p pump bowl assembly fitting, repairing of starter, rewinding of 90 h.p. starter trasformer capacity with f class copper wire insulation including air drying ,varnishing with dr. bake warmish, backtoling, including all cost of skilled labour, dismantling trasformer transportation , loading, unloading, erection, and giving trial and testing and applicable of all taxes. (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote.), rewinding of 60 h.p. starter trasformer capacity with f class copper wire insulation including air drying ,varnishing with dr. bake warmish, backtoling, including all cost of skilled labour, dismantling trasformer transportation , loading, unloading, erection, and giving trial and
Tender For design, supply, installation, testing and commissioning internal piping (ip) for piped natural gas (png) as per pngrb guidelines and as per specification mech/mh/png/4200/gm dated 08.06.2026
Tender For supply of hi wall split ac 2.0 tr 5 star , hi wall split ac 1.5 tr 5 star , hi wall split ac 1.0 tr 5 star , stabiliser 5 kva for 2.0 tr ac , stabiliser 4 kva for 1.5 or 1 tr ac , insulated copper refrigerant piping set for 2.0 tr split ac , insulated copper refrigerant piping set for 1.5 and 1.0 tr split ac , wire or cable , pvc pipe , ms angle , installation testing and commissioning of ac , dismantle shifting reinstallation
Tender For supply of set of pipe fittings for co-co bogie piping (wag-9hc & wap-7) to set list el29230524 rev."1 " & spec no. clw/ms/3/053 alt.21 with latest alteration & str no. clw/2018/eldo/m/str/050 dt. feb. 2019 rev 0 with latest. drg. no./spec.:- clw's spec no. clw/ms/3/053 alt.21 with latest & str no. clw/2018/eldo/m/str/050 dt. feb. 2019 rev 0 with latest. [ warranty period: 30 months after the date of delivery ] ]
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For providing of custom bid for services - 200155022 biennnial rate contract for running & breakdown maintenance and overhauling of pf piping bends & g feeder of milling system stage i 5x200 mw & stage ii 2x500 mw ntpc singrauli
Tender For corrigendum : erection and commissioning of power cycle piping and its auxiliaries, boiler integral piping, associated lp piping etc. of unit-1, unit-2 and common systems at 2x800 mw ntpc singrauli stpp stage-iii
Tender For framework agreement for fabrication of air cooler piping items such as main header pipes, nozzle assembly and inlet/outlet distribution piping/nozzles.