Web Analytics Made Easy - StatCounter

Plastering Tenders

Get complete information related to latest Plastering Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plastering Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plastering Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45284853 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For supply of bathing soap bar (v3) conforming to is 13498 (q4) , scouring products for utensil cleaning- dishwash (v3) conforming to is 6047 (q4) , quaternary ammonium compound based surface cleaner (liquid) (v2) conforming to is 14364 (q4) , toilet paper (v3) conforming to is 14661 (q4) , facial tissue papers(v3) (q4) , household laundry detergent powders (v2) conforming to is 4955 (q4) , laundry soaps (v2) conforming to is 285 (q4) , toilet brush (v3) (q4) , domestic wiper/wiper mopper (v3) (q4) , air freshener liquid (v3) (q4) , hdpe bucket (v2) conforming to is 3730 (q4) , glass tableware (v2) conforming to is 1961 (q4) , wall clocks (battery operated) (v2) conforming to is 12510 (q4) , dining bowl (v3) (q4) , esd slippers (q4)

State Government

CTN :45311564 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For repair to lord jagannath temple and radha mohon temple, baripada for the car festival for the year 2026-27 (such as plastering and painting)

State Government

CTN :45289600 Due date: 02 Jun, 202602 Jun, 2026 20.51 Lacs
Tender For special repair to old medicine building in scbmch cuttack (such as out side painting, plastering, grading concrete and other repair etc. ) for the year 2026-27

State Government

CTN :45314214 Due date: 03 Jun, 202603 Jun, 2026 68.06 Lacs
Tender For balance work of construction of external rcc surface drain in sector-14p-ii hisar

Central Government / Public Sector

CTN :45213408 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For corrigendum : supply of pressure transmitter -1 to 5 kg per sqcm , pressure transmitter 0 to 10 kg per sqcm , pressure transmitter 0 to 20 kg per sqcm , pressure transmitter 0 to 200 kg per sqcm , remote seal pressure transmitter 0 to 200 kg per sqcm , differential pressure transmitter , temperature transmitter - surface mounted weldpad , temperature transmitter - sub soil , temperature transmitter - thermowell , differential pressure level transmitter

State Government

CTN :45275642 Due date: 02 Jun, 202602 Jun, 2026 3.07 Lacs
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging

State Government

CTN :45274161 Due date: 01 Jun, 202601 Jun, 2026 12.50 Lacs
Tender For supply of laboratory equipment and others materials for existing, accredited district water testing distt. laboratories of division chhindwara - external calibration of laboratory equipment refrigerator/ , visi cooler rtd probe with sensar, glass thermometer, thermometer, wet and dry , thermometer, balance, analytical weight box,ph meter, tds meter, turbidity meter through iso/iec 17025:2017 accredited calibration laboratory with calibration certificate , smart uv-vis spectrophoto meter; 2206 touch screen uv-vis spectrophoto meter, wavelength range 190-1100 nm, accuracy + 1.0 nm, resolution 1.0 nm, bandwidth 1.0 nm. cuvette holder 50 mm path length. with display, with two years amc. with calibration certificate of control of absorbance, resolution power, limit of stray light. light source xenon flash lamp/tungten lamp/ deuterium lamp. to be supplied with 2 pairs of quartz cuvette. size 10 mm. including cost of supply, installation & training to lab staff for making graph of iron, nitrate, flouride, maganese test at nabl accredited lab with certificate. (nabl ceritified) make systronics , color comprator for color analysis , hot plate: rectangular body- heating upto 300'c are fitted with insulated elements. workable on 220/230 volts a.c. surface with cast iron top 300x450x150 mm rating 2 km with digitally , bacteriologycal incubator (memmert type with digital controllar): double walled, outer made of gi/ms powder coated. element of three sides' ss chamber digitally controlled temp. range 5'c above rt to 70 c + 0.5'c fitted with fan having double viewing sindow, supplied with shelves workable on 220/230 volts a.c. size 455x445x455 mm deluxe model with nabl certificate , ion meter versastar banch top modal (ph/ise)with flouride combination, epoxy body electrode with range form 0.01 mg/l ph ross electrode bnc connector, power syplly card opration manual, usb cable, universal ac power adaptor 90-260v ac electrode holding stand, stirrer (1) one pack flouride filling solution 475 ml (2) flouride standard 100 ppm 475 ml solution (3) flouride electrode storing solution 475 ml x 2 no (4) tisab iii solution 475 ml x1 including cost of supply, installation & training to lab staff for making graph of iron, nitrate, flouride, maganese test at nabl accredited lab with certificate. (nabl ceritified lab) , fluoride electrodes (combination fluoride electrode epoxy body with bnc connector) thermo orien -960913 nwp , monoquartz distillation unit-3362 dist. water output cap. (approx) 4.0 lt.hr/ electrical requirements 230-250 volts single phase 3.5x 2kw quartz heater/minimum cooling water requirment 2.5 lit/ min (ea)/ biological activity pyrogen free/ conductivity s/cm <1 x 10-6/ distillate temp 65-75'c , plate colony counter model no. cc-100 220 woult 1 year worenty measurement range 0 to 999 semi autometic precise colony counting metal plastic , laboratry refrigerator rlr-300 cooling type frost free temp. rang 2'c to 8'c glass dour 1, width 584, depth 584,hight 1702,220-240 woult 50 hz singal face , sampling bottel capicity 1 itr , membran filter assembley 5360 all galss filter holder 47mm filtretion assembley made for borosilcate glass with filter base capicity-21tr , spare for all glass filter holder 47mm dai capicity 2000ml for filter holder . tissu paper roll 3 layer

State Government

CTN :45316319 Due date: 15 Jun, 202615 Jun, 2026 5.94 Lacs
Tender For arboriculture work ....surface cscheme

State Government

CTN :45313890 Due date: 03 Jun, 202603 Jun, 2026 5.30 Lacs
Tender For shiftingofexisting hdpe pipelineandlaying from bwl to the glr in the inside premises campus of iiser kalyani at kalyani block of surface water based pwss for haringhata chakdah part ws scheme under nad i phe dte.

State Government

CTN :45164232 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For corrigendum : repairing of the 800 kva avr at bs-ii surface water supply scheme under south 24 parganas mechanical division, phe dte.
 Loading, Please wait...

Connect us via What's Up