Get complete information related to latest Plastic Bottle Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plastic Bottle Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plastic Bottle Tenders.
Tender For corrigendum : purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopa
Tender For corrigendum : supply of vacuum circuit breaker (single bottle) as per clw specn. no. clw/es/c-47/alteration-i with matching accessories suitable for 3-phase wap7/wag9hc locomotives. each set consists of - (1) vcb assembled - 1 no. (2) male connector 1/2 x 3/8 - 03 nos. (3) male connector (inbuilt in vcb) - 01 set (4) hose pipe 3/8
Tender For auction sale of u/s air heater element scrap with boxes,u/s grinding roll steel scrap,u/s boiler tube/coil all type except cut piece, coil scrap,u/s cooling tower pvc v bar scrap,u/s empty plastic jerry can 50 ltr cap scrap,u/s oil plasticbottles and plastic seals and other plastic scrap,u/s fluorescent and other mercury containing lamps
Tender For supply of glassware and chemicals as per our terms and technical specification - amyl alcohol (2 litres), sulphuric acid (20 kg), heater, nylon brush for cleaning 50 ml milk sample bottles, nylon brush for cleaning pipettes, test tube stand for 12 tubes 18x150 mm, plastic tilt measure 10 ml for acid with rubber cork and with plasticbottle of 250 ml, plastic tilt measure 1 ml for alcohol with rubber cork and with plasticbottle of 100 ml, tray for reagents , plastic tray for holding 24 nos sample bottles, plastic sample bottles 50 ml with cap, sprit lamp stainless steel 100ml, porcelain dish 3 inch., glass beakers 500 ml, glass beakers 100 ml, test tubes 18x150mm, milk pipette 10 ml, graduated pipettes 10.75 ml, thermometer (alcohol), lactometer., lock stopppers with pins, milk butyrometer.
Tender For corrigendum : supply of sch i (supply of injections & sera vaccines) - sch i (supply of injections & sera vaccines), inj. b complex for prophylactic use vit. c 150 mg vit. b 12 2500 mcg folic acid 0.7 mg niacinamide 12 mg, inj. b complex for therapeutic use each ml contain vit a 1000 iu cholecalciferol 100 iu alphatochopherol acetate 0.5 mg. thiamine 5 mg. pyridoxine 0.5 mg. nicotinamide 10 mg. ascorbic acid 50 mg. d-panthenol 2.5 mg., inj. calcium gluconate 10% iv use., inj. desferroxamine 500 mg, inj. digoxin 0.5 mg iv use, inj. diltiazem 5 mg/ml, inj. fluconazole 200 mg. in plasticbottle, inj. fluorescein sodium (20%), inj. hydralazine 20 mg. iv, inj. hyaluronidase 1500 iu, inj. insulin plain (purified human) 40 units/ml sc/iv use (insulin plain and insulin nph/ lente should be of the same manufacturer and their rate will be considered as a unit.), inj.insulin nph/isophane40 iu (highly purified bovine porcine isophane insulin susp 40 i.u./ml nph insulin (or neutral protamine hagedorn)., inj. isoxsuprine hcl 10 mg/ml., intravenous injection of n (2)-l alanyl-l glutamine 20%, solution 50 ml, iv lipid 20% for neo-natal use., inj.lorazepam 2 mg/ml im/iv use., inj. l-ornithine l-aspartate 5 gm, inj. n-butyl cyanoacrylate 0.5 gm., inj. methylene blue 10 mg/ml, inj. metoprolol 5mg, nitroglycerine lingual spray in ready to use formulation. each spray should deliver 0.35 to 0.4 mg/spray 60-70 lit/spray., inj. phenobarbitone sodium 200 mg iv use, inj. protamine sulphate 1% iv use, inj. somatostatin 3 mg /vial, sterile & pyrogen free water for injection i.p 5ml, inj.sterile & pyrogen free water for injections i. p. 10 ml, inj. thiamine 100 mg/ml, inj. tricort triamcinolone sodium 10 mg, inj. tuberculine p. p. d. 5 t. u./0.1 ml intradermal use., inj. vit. k 10 mg/ml (aqueous) i. m./i. v., inj. valethamate bromide 8 mg, inj. benzathine penicillin 6 lacs unit for im use, inj. benzathine penicillin 12 lacs unit im use, inj. benzyl penicillin/ penicillin g/ crystalline penicillin salt 1000000 units/bulbs i. m./i. v., inj. ofloxacin 200 mg, inj. streptomycin sulphate 0.75 gm, inj. anti d 300 microgram/dose polyclonal/monoclonal, inj. diptheria antitoxin 10000 iu, inj. hepatitis b vaccine recombinant dna technology 20 mcg/ml, inj. hib vaccine 10 mcg. haemophilus influenza type b. polysacchride conjugate vaccine. [powder to be reconstituted with 0.5 ml diluent (saline)]., inj. human rabies immunoglobulin 150 i.u./ml, inj meningococcal conjugate vaccine single dose vial containing (a, c, y & w 135) polysaccharide conjugated to diptheria toxoid protein carrier., inj. mmr vaccine (measles, mumps & rubella) single dose im or sc., inj. pneumovax (pneumococcal 23 valent vaccine), inj. polyvalent antisnake venom serum- should contain equivalent of 10 ml of purified globulins 1 ml of reconstituted serum to neutralizes 0.5 mg to 0.6 mg of dried cobra venom, 0.45 mg of dried common krait venom, 0.6 mg. of dried russells viper venom, 0.45 mg of dried saw scaled viper venom, liquid or powder form will be accepted, inj. rabies human monoclonal antibody (rdna) 40 iu/ml., inj. tetanus vaccine purified toxoid adsorbed i. p. 5 lf./0.5ml, inj. tetanus immunoglobulin (human) 250 i. u. im / intrathecal use., inj. tetanus immunoglobulin (human) 500 i. u. im / intrathecal use., inj. lignocaine 10% spray, inj. propofol 1% mct/lct fat emulsion with sodium oleate 50 ml, inj. ropivacaine hcl 0.5%, inj. 2% hydroxypropyl methyl cellulose preservative free sterile for intraocular use during cataract surgery in sterile prefilled syringe & with sterile cannula., intracameral injection lignocaine hydrochloride 1%, inj. perfluoro-n-octane liquid for intraocular use sterile, inj. pilocarpine (0.5%) nitrate/hcl sterile opthalmic solution for injection., inj. silicon oil for (polydimethyl siloxane for intraocular use) sterile viscosity 1500 mm2/s cst, inj. sodium hyaluronate 1.4%, inj. sodium hyaluronate 1.8%, inj. continuous ambulatory peritoneal d
Tender For corrigendum : supply of glassware and chemicals (like milk butyrometer (2500 x 4)/ lactometer (2500 x 2)/ thermometer (alcohol), 0 to 1000 c, yellow back, accuracy 100% (2500 x 2)/ graduated pipettes 10 ml (2500 x 5)/ milk pipette 10.75 ml (2500 x 5)/ test tubes 18 x 150 mm (2500 x 10)/ glass beakers, 100 ml (2500 x 2)/ glass beakers, 500 ml (2500 x 2)/ porcelain dish, 3 inch (2500 x 2)/ sprit lamp, stainless steel, 100 ml. (2500 x 2)/ plastic sample bottles, 50 ml, with cap, made from food grade plastic, minimum weight-5.5 gm (2500 x 60)/ plastic tray for holding 24 nos. sample bottles securely, made from food grade plastic, minimum weight 300 gm +_10 gm (2500 x 3)/ tray for reagents, size 16x12 inches, made from food grade plastic (2500 x 2)/ plastic tilt measure 1ml for alcohol with rubber cork & with plasticbottle of 250 ml. (2500 x 2)/ plastic tilt measure 10 ml for acid with rubber cork & with plasticbottle of 500 ml (2500 x 2)/ test tube stand for 12 tubes of size18x150mm, aluminum/ nylon brush for cleaning pipettes, nylon length 4 inches, total length 12 inches (2500 x 5)/ nylon brush for cleaning 50 ml milk sample bottles, nylon length 4" with tail & thick steel wire (2500 x 5)/ heater/ sulphuric acid (20 kg) and iso amyl alcohol (2 litres)) on running rate contract basis for one year. and for supply of milk collection accessories (like milk can 40 litres (ss) (set of 5 can each dcs) 2500 x 5/ milk collection tray, made 1.2mm thick ss 304, size 440x 590x65mm, minimum weight -4200gm/ milk sampler, made from 1.2mm thick ss 304. minimum weight -90gm/ funnel with strainer, made from 1.2mm thick ss 304. minimum weight -1600gm/ strainer sieve for funnel, material ss 304/ measure 100 ml, made from 1.25mm thick ss 304. minimum weight 125gm/ milk can plunger, made from ss 304. minimum weight-650gm/ milk bucket, made from ss 200 series, seamless with bottom ring, 15 litre capacity. minimum weight -1600 gm (set of 2) 2500 x 2/ plastic hammer for can opening)