Get complete information related to latest Plastic Pipe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plastic Pipe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plastic Pipe Tenders.
Tender For tender for supply of plumbing items at iim ranchi - upvc pipe 2" sch40upvc coupler 2"upvc elbow 2"upvc tee 2"upvc elbow 45 (shoo) 2"upvc mta 2"upvc fta 1.5"upvc r-bush 2" x 1.5"upvc union 2"upvc solvent 200mlupvc pipe 1.5" sch40 (submersible pipe)dol (direct online starter) starter with panel for motor3 core cable 4 sqmmpvc ropeadaptor/connector (size: 1.5")8" gi boring cap1.5" gi clamp1.5" gi elbow1.5" x 6" gi nipple
Tender For rate contract of building materials supply for fy 2026-27 for grampanchayat arda ta.sironcha - material items :, sand, murum, bricks, cement grade - 53, metal 80mm hand, metal 40mm crusher, metal 20mm crusher, metal 10mm crusher, steel 18mm, steel 16mm, steel 12mm, steel 10mm, steel 8mm, steel 6mm, binding wire (centring wire), pvc pipe 110mm, pvc pipe 90mm, pvc pipe 75mm, pvc pipe 63mm, upvc pipe casing 160mm, valve 75mm, valve 63mm, paver blocks, syntex water tank 5000 litter, syntex water tank 10000 litter, water tap (toti) 1/2 inch, water tap (toti) 1 inch, tiles (ceramic), verified tiles 2x4, iron sheet, iron angle, nails, iron door with frame and palla, iron window with frame and palla, chicken mesh net, water proofing liquid, water proofing polymer, asian paints, wall care putty, sliding window with glass panel, grill, mixture machine with operator, jcb with operator, tractor with driver and labours, tractor water tanker with driver, plastic emulsion paint, oil bond distemper
Tender For maintenance of day to day complaints of water supply including connected items at various loc under ge nagrota - m&l for repair/rectification of leakage to water supply distribution lines 15 mm dia to 25 mm dia gi tubing by necessary excavation, returning/filling as required, tightening of loose joints of union, elbow, socket etc, threading if required including replacement of gi union/socket/nipple as required complete all as specified and directed., all as per srl item no.1 above but for gi tubing of 40 mm dia to 50 mm dia complete all as specified and directed., all as per srl item no.1 above but for gi tubing of 80 mm to 150 mm dia complete all as specified and directed., all as per srl item no.1 above but for gi tubing /di /ci /ms of 150 mm dia to 300 mm dia complete all as specified and directed. note : (i) the complaints for the above works shall be registered by contractor at the water supply complaint cell of age e/m (ii) stationary required such as complaint book, job cards etc shall be arranged by the contractor and proper record shall be maintained by the contractor.(iii) tools ,plumber with helper and transport with driver for attending of above complaints shall be arranged by contractor. (iv) the rate quoted by the contractor for above jobs under item no 1 to 4 shall be inclusive of cost of works under note (i) to (iii) above. (v) the said complaints shall be rectified within 12 hrs of the registration of the complaints failing which recovery of rs.500/commplaint shall be made for contractors due payment (vi) the stores/item required for the works under item no 1to 4 shall be measured separately under relevant item as supply only. (vii) excavation, returning/ filling shall be measured and paid for separately and material required for the works above shall be included to quoted rates., excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep including getting out in hard/dense soil complete all as specified and directed., returning /filling including watering , leveling , spreading and well ramming in layers not exceeding 25cm thick complete all as specified and directed., removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 50 metre above the starting point complete all as specified and directed., refixing/relaying of old retrieved steel tubing in new or old position with and including new gi fittings (connections) and as per site requiremen laid in trenches, above ground level or in any position of following sizes as under complete all as specified and directed : -, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, taking down unserviceable gi tubing / upvc tubing from any position complete with all fittings & connections from any position of following sizes as under complete all as specified and directed :-, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply and fixing/laying & testing of galvanised steel water tubing, medium grade, isi marked complete with all new galvanized fittings of following sizes laid in trenches/ above ground level or in any position complete all as specified and directed :, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply and laying upvc pipe tubings medium grade pressure rating 10 kgf/cm2 isi mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trenches or in any other position of following sizes as under complete all as specified and directed , 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply only gi fittings, medium grade, isi marked of following sizes as under complete all as specified and directed :-, union 15 mm dia, union 20mm dia, union 25mm dia, union 32mm dia, union 40mm dia, union 50mm dia, socket 15 mm dia, socket 20 mm dia, socket 25 mm dia, socket 40 mm dia, socket 50 mm dia, reducer socket 40mmx50mm, reducer socket 15mmx20mm, reducer socket 20mmx25mm, elbow 15mm dia, elbow 20mm dia, elbow 25mm
Tender For sinking of 1 one no. 300 mm x 200 mm dia. tubewell 140 mtr. deep by d.r. method with upvc pipe and upvc ribbed strainer at kalinagar pump station in ward no 8 under krishnanagar municipality sl no 02
Tender For sinking of 1 one no. 300 mm x 200 mm dia. tubewell 140 mtr. deep by d.r. method with upvc pipe and upvc ribbed strainer at rathtala pump station in ward no 9 under krishnanagar municipality sl no 06
Tender For sinking of 1 (one) no. 300 mm x 200 mm dia. tubewell 140 mtr. deep by d.r. method with upvc pipe and upvc ribbed strainer at saktinagar pump station in ward no 10 under krishnanagar municipality.sl no 01
Tender For sinking of 1 one no. 300 mm x 200 mm dia. tubewell 140 mtr. deep by d.r. method with upvc pipe and upvc ribbed strainer at radhanagar pump station in ward no 3 under krishnanagar municipality sl no 05