Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging
Tender For providing of facility management services - lumpsum based - industrial; non radiation area-- shifting of piping material from welding shop --1 lumsum quantity is equal to 10000 having unit of measurement is inch meter--for complete details refer boq item no 1(a) ..,facility management services - lumpsum based - industrial; non radiation area-- fabrication and erection including welding of --1 lumsum quantity is equal to 35 having unit of measurement is metric ton--for complete details refer boq item no 1(b) me..,facility management services - lumpsum based - industrial; non radiation area-- dismantling of pipe and structural steel items --1 lumsum quantity is equal to 40 having unit of measurement is metric ton--for complete details refer boq item no 1(c) me..,facility management services - lumpsum based - industrial; fabrication of pipe clamp set for on-line leak rectification in system --1 lumsum quantity is equal to 800 having unit of measurement is inch dia--for complete details refer boq item no 1(d) ..,facility man
Tender For supply of magnetic particle testing machine , submerged are weldingmachine , frication weldingmachine , fume extractor system , rockwell hardness testing machine
Tender For supply of hood dryer , d.c. shunt generator with 3phase squirrel cage induction motor , ac squirrel cage motor , solar street light , solar traffic light , d.c. shunt motor , shaded pole motor , dmx controller , battery charger , meter reading instrument , magnetic particle testing kit , plasticweldingmachine with hot air gun
Tender For supply of a portable shelter , arrangement for transportation , steel structur , electricla items , external elect store , furniture items - shs 100 x 100x 4.0 mm thick. make: sail /tata / apollo / equivalent isi marked, shs 50 x 50x 2.00 mm thick. make: sail /tata / apollo / equivalent isi marked, rhs 100 x 50x 4.05 mm thick. make: sail /tata / apollo / equivalent isi marked, ms plate 20 swg /1 mm thick as in wall (outer body), ms plate 18 swg /1.22 mm thick as in roof (outer body), ms plate 26 swg /0.46 mm thick as in secondary outer body., 4 mm thick acp sheet (inner) (make alstone/eurobond/ aludecor/ alstrong), hybrid (poly-isocyanate) pir panel insulation shall be provided using 45 mm thick density of 48 kg/m³ with aluminum foil one side, hdf laminated wooden flooring 8 mm thick (make - action tesla/centurry/pergo/greenpanel/micasa), 19mm thick ply make: kitply / green ply / century ply, steel doors: one number of door of size 900mm x 1800mm with inside opening shall be provided with complete accessories., steel doors: one number of door of size 900mm x 2100mm with inside opening shall be provided with complete accessories., detachable ms steps: 1x ms steps of size 600 x 300 mm 6 tier of steps made up of ms angle of size 40mm x 40mm x4mm (wt not less than 4.20 kg/m) would be provided. reference drawing as directed and approved make: sail/tata/jindal, pop rivet 3m x ½”, pop rivet 4m x ½”, welding rod n. 10, primer paint, ir absorbent paint camouflage pattern, metal putty, rubber solution, hydraulic jack with rubber hoses and fittings, electrically operated winch assy, jack side support 2 ton, map boards 6' x 6' with all accessories, vps / projector system stand, canvas cover 30'x30', 3 kg fire extinguisher & fire ball, self screw 25x1, multi spectral camoflauge net, led concealed light 9’’ x 9”x 22 watt, make- havells/ bajaj/ crompton), entrance light (bucket light), ac starter with fittings and mcb, single core wire 2.5mm, single core wire 1.5mm, single core wire 1 mm, insulation tape, modular s/w with cover on/off 5/15, socket 5 amps 3 pin, socket 15 amps 3 pin, switch boards 10 “ x 10”, switch boards 6” x 6” & 6” x 3”, exhaust fan 300mm, work station/ partition, wall mounted fan 450mm, focus / spot light for mapboards, hdmi cable for projector, led screen (sonic view / equivalent) 65'" (164 cm) with modular stand 4k ultra hd (3840 x 2160) etc. make - samsung / sony, de-humidifier 1.5 ton with stablizer and complete fittings etc. make- voltas/ daikin/lg/blue star/ panasonic., electric connections. cables to be used should isi marked of make havells/ crompton greeves/ plaza , fire retardant material. 1.5 sqmm cable to be used in all light points and 2.5 sqmm cable to be used in power points. 18 watt & 11 watt leds of make: cromptongreaves/bajaj/havells/syska . shall be provided at all light points. all switches to be used should be of 6 amp modular type of havells/anchor /crompton greeves/ general electric. the fwg electric connections shall be provided for :-, (ii) power point of 5 pin15 amp socket and 8 nos switch combination of modular type all switch point will be modular type will be provided as approved of make crompton greave/bajaj/havells ., (iii) concealed conduits will be provided for cabling in the portable shelter set of pvc insulated cable 1.5/2.5 sqmm multistanded copper conductor single core 1100v, grade conforming to is 649/1990 of make havells/finolex/plaza, (iv) mcb dp 32amps conforming to is 8828-1996 make crompton greave/ bajaj/havells, (v) miniature circuit breaker (mcb) 6 amp to 32 amps (single pole) make : crompton reave/bajaj/havells., (vi) change over over 63 amps, 3 pole of make: crompton greave/bajaj/havells., cable jointing kit for 11kv (earthed) grade cable for straight through heat shrinkage type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminum conductor cable of size 16 sqmm to 35 sqmm, power backup (ups/ inverter system) capacity 3
Tender For supply of alumino thermit welding portions (using compressed air petrol/lpg pre heating system) 3piece prefabricated mould (zircon washed) manually pressed, single shot crucible fitted with auto tamping timble for south central railway as per rdso specification no. irst/19-2020 and as amended uptothe date of opening of tender. 52 kg/90 uts - 25 mm gap (with accessories as anexure) [ warranty period: 30 months after the date of delivery ]
Tender For supply delivery and fitting fixing of gaseous chlorination items for the standby system of clear water pumping station and supply of 1 no empty chlorine tonner at ibs uporgora under chhatna, saltora block sub-surface water based piped water - supply and delivery of gaseous chlorination unit spares (0-10kg) & (0-4kg)kg/hr. require of wallace & triman evoqua, vacuum regulator (wall/cylinder mounted)with auto switchover facility, capacity 0-10 kg/hr max, evoqua make s10k scale controller, capacity 10.0kg/hr, manual control, evoqua make 1 injector suitable for 40 psi backpressure, fitting fixing of the above new supplied spares on the existing position part by part with new ejector pipe line with necessary fitting materials and necessary welding job by expert mechanical complete the job as per direction of eic and as per is:10553., supply and delivery at site of 1000 kg empty chlorine tonner hydraulic test pressure 30 kgf design as per asme section viii div.1 with hot-forged steel hook and a safety tongue piece, add: 18% gst, add: 1% cess