Web Analytics Made Easy - StatCounter

Platinum Tenders

Get complete information related to latest Platinum Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Platinum Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Platinum Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45146882 Due date: 25 May, 202625 May, 2026 1.00 Crore
Tender For empanelment for the supply of cathlab items on running contract basis under kasp and other schemes of this hospital - coronary stents, des,everolimus,fda/dcgi/ce approved platinum chromium platform,polyvinylidene fluride-hexafluropropyline pvdf-hfp polymer-stent lengths8,12,16,24,28,32. stent diameter 2.25*,2.50,2.75,3.00,3.50,4.00.struct thickness 81/86 microns.nominal pressure - 11 atm,rated burst pressure 16-18 atm, des,everolimus,fda/ approved platinum chromium platform,polyvinylidene fluoride-hexafluropropylene(pvdf-hfp)polymer, des,everolimus,fda/dcgi/ce/ approved platinum chromium platform,bioabsorbable polymer plga, everolimus eluting platinum chromium stent system, des, everolimus, l 605 cobalt chromium with hybrid cell design , strut thickness- 65microns, polymer- plga diameter- 2.25, 2.5, 2.75, 3.0, 3.5,4. length- 10,13,15,18,20,24, 28, 32,36,40, 42, 44, des, everolimus, cobalt chromium strut thickness - 63 microns . diameter- 2.25,2.5,2.75,3,3.5,4. length- 8,10,13,15,18,20,24,28,32,36,40,42,44. elutes 80% of drugs along with re plga polymer in the first 20 days, dcgi approved everolimus drug eluting 65 micron strut thickness with 3 micron plla&plga. a unique proprietory coating technology basedbiodegradable polymer stent with open cell designed and flexia finished technology based cobalt chromium l605 stent.a designed for optimal strength, flexibility ,trackablity ,side branch supported,bifurcation supported and high radial strength and optimal radiopacity and excellent vessel supported stent with revers alternative link design(ral) stent, with length from 8 mm to 52 mm and diameter from 2.25 mm to 4.50 mm, ce approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., ce approved sirolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., only dcgi approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 deg

Central Government/Public Sector

CTN :45106072 Due date: 25 May, 202625 May, 2026 17.47 Lacs
Tender For corrigendum : comprehensive annual maintenance contract psm service (platinum) for 9 nos passenger lifts (oem- m/s johnson lifts pvt ltd) at csir-cmeri colony and institute, durgapur

Central Government And Public Sector

CTN :45109823 Due date: 29 May, 202629 May, 2026 NA
Tender For request for proposal for rate identification for providing bulk sms service to eb platinum mumbai customers

CTN :45281561 Due date: 11 Jun, 202611 Jun, 2026 59.46 Lacs
Tender For tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life

Central Government / Public Sector

CTN :44052106 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For corrigendum : outright sale of ccru spent catalyst/fines/dust containing platinum as precious metals at iocl, paradip refinery, paradip.

Central Government/Public Sector

CTN :45254443 Due date: 03 Jun, 202603 Jun, 2026 NA
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus, everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval shouldbe enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent toa major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45254856 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For srphc82281215-coronary drug eluting stents (1) with single wire design with cobalt alloy shell and platinum iridium core (2) stent with coating of biolinx polymer carrier for active drug zotarolimus shown to be effective in preventing neo-intimal hyperplasia (3) stent diameter should be from 2 mm to 5mm and length of the stent from 8 mm to 38 mm. (4) the strut should be round with thickness ranging from 81 to 91 microns (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) five years efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute. ]

CTN :45261517 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For supply of smpastnry c c - junction box 05 socket point 05 meter, 1500w , teflon tape 10 meter , double edge razor blade super platinum 500 nos pack box , premium tracing paper sheet a4 transparent 100 sheets , a4 photo sheet 230 gsm , a4 sheet 80 gsm jk copier , permanent marker black , paper clip 50mm steel large , paper clip small , paper binder 25 mm rust resistant steel , rubber band nylon , epson ink bottle 008 model 127ml black colour , fevicol sh synthetic resin adhesive 01 kg pack

Central Government/Public Sector

CTN :45269102 Due date: 30 May, 202630 May, 2026 17.68 Lacs
Tender For auction sale of land - e,504,swastik platinum,nr pooja farm,narol aslail highway,narol,ahmedabad,gujarat-382440,ahmedabad,india.

CTN :44561157 Due date: 22 May, 202622 May, 2026 NA
Tender For bid to ras supply of everolimus eluting platinum chromium stent on dual layer balloon with biodegradable polymer assorted size , everolimus eluting drug coated cobalt chromium coronary stent system non erodible polymer, assorted sizes , ptca ballon dilatation catheter rapid exchange assorted size , rapid exchange non compliant balloon with slider hydro from tip to adjacent guidewire port external surface eel coating for guidewire lumen , single chamber aicd complete with accessories mri compatible , ptca balloon dilatation catheter rapid exchange non compliant , semi crystalline copolymer non compliant balloon with hypotube design technique , covered stent graft 8-10mm 40-60mm length , n c quantum apex- 0 point014inch ptca balloon rapid exchange non compliant , permanent pacemaker dddr complete set with lifetime warranty mri compatible , ptca rapid exchange scoring balloon , drug eluting coronary balloon with urea paclitaxel coating assorted sizes , 3t mri compatible dddr pacemaker with blue sync technologyenabling ) /bid number : gem/2026/b/7143784 * /dated: 20-03-2026 & & / bid document 1 / 17
 Loading, Please wait...

Connect us via What's Up