Web Analytics Made Easy - StatCounter

Plb Pipe Laying Tenders

Get complete information related to latest Plb Pipe Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plb Pipe Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plb Pipe Laying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45721834 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supplying electrical materials and repair maintenance services for street lights and electrical works at. grampanchayat somatane - electrical material, supplying and erecting modular type switch6a / 10a ., supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded ., providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation ., supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification, supplying,tpmcb 40a to 63a in provided distribution board, providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply., supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse, supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, 1.25 mm crca sheet metal enclosures with 20a., supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable ., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink ., supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium ., supplying & laying pvc armoured cable 4core 6sq mm, supplying & laying pvc armoured cable 4core 10 sq mm, supplying & laying pvc armoured cable 2core 10 sq mm, supplying & laying pvc armoured cable 4core 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting), supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting), supplying, erecting & marking tpmcb 6 a to 32amp ., supplying, erecting & marking fpmcb 40a to 63a ., supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm., supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials., supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunk

State Government

CTN :45743518 Due date: 21 Jul, 202621 Jul, 2026 37.66 Lacs
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- koti(imlidand,khaspara,korwapara) koti(panditpara) koti (daridih, pateratola, purankoti) block- wadrafnagar district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 840 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 550 m., 75 mm dia. 1000 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 0 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village-koti(imlidand,khaspara,korwapara)koti(panditpara) koti(daridih,pateratola,purankoti) block- wadrafnagar district – balrampur(c.g.)

State Government

CTN :45743537 Due date: 21 Jul, 202621 Jul, 2026 10.72 Lacs
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1300 m., 75 mm dia. 127 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 46 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)

State Government

CTN :45719782 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of materials for mgnrega works - supply of materials, earth, coal (steam), carriage of tar bitumen, bitumen vg-30, bitumen emulsion, stone screening type a (13.2 mm), stone screening type b (11.2mm), stone screening type a (13.2 mm), coarse sand, stone aggregate(single size): 06 mm nominal size, grade 1 stone metal 63 mm to 45 mm, 1st class picked jhama bricks(traditional), 1st class bricks, coarse sand, stone boulder ( 225mm-150mm ), coloured inter locking c.c. paver block, fine sand, silver sand, portland cement, stone aggregate(single size):20 mm nominal size, stone aggregate(single size): 10 mm nominal size, loading unloading & stacking sand/ stone aggregate (less than 40mm nominal size), stone aggregate(single size): 40 mm nominal size, precast cement concrete blocks (nominal mix. 1:1.5:3 with 20 mm down coarse aggregate including supplying at site, laying and finishing the top surface with 1:3 cement mortar), medium sand, udaypur marble slab ( for floor, lobby etc) 18 mm thick of size 0.3 sq m to 0.6 sq m, chawk dungri marble slab ( for floor, lobby etc) 18 mm thick of size 0.3 sq m to 0.6 sq m, udaypur marble slab ( for wall/dado) 18 mm thick of size 0.3 sq m to 0.6 sq m, chawk dungri marble slab ( for wall/dado) 18 mm thick of size 0.3 sq m to 0.6 sq m, ceramic glazed tiles ist quality 300 x 300 mm in all shades and designs of white, ivory, grey, fume red brown etc., rectified - ceramic glazed tiles ist quality 300 x 300 mm or more in all shades designs white, ivory, grey, fume red brown etc, vitrified floor tile 60x60 cm, precast chequered cement tiles 22 mm thick dark shade using ordinary cement, hire charges of concrete mixer 0.25 to 0.40 cum with hopper, vibrator (needle type 40 mm), water tanker 5000 ltr. capacity, r.c.c. pipes np2 class 300 mm dia, r.c.c. pipes np2 class 450 mm dia, rcc pipe 600 mm dia np- 3 spigot, carriage of r.c.c. pipes 600,700,750 & 800 mm dia, loading, unloading & stacking by manual means (r.c.c. pipes , c.i. pipes and unreinforced cement pipes) 600, 700, 750 & 800 mm dia, rcc pipe 900 mm dia np - 3 spigot, carriage of r.c.c. pipes 900 mm dia, loading, unloading & stacking by manual means (r.c.c. pipes , c.i. pipes and unreinforced cement pipes) 900 mm dia, empty gunny bag, bamboo (8cm-10cm dia) including fixing, nail, sal bullah (7.5cm -10cm dia), eucalyptus bullah (7.5cm -10cm dia), sal bullah (12.5cm -15cm dia), sal bullah (17.5cm -20cm dia), eucalyptus bullah (7.5cm -10cm dia), eucalyptus bullah (12.5cm -15cm dia), eucalyptus bullah (17.5cm -20cm dia), sausage wire net, galvanised steel corrugated sheets, galvanised steel bolts & nuts 6 mm dia and 25 mm long round head with slots, galvanised steel j or l hooks 8 mm dia, false ceiling (with 4mm thick pearl designer fibre cement board), supplying, fitting & fixing asbestos corrugated sheet(6 mm thick), supplying, fitting & fixing asbestos ridging, supplying, fitting & fixing zn-al alloy steel sheet work in roof, supplying, fitting & fixing aluminium sheet ridging, fitting and fixing glass reinforced polyester translucent fiber glass sheet, fitting and fixing glass reinforced polyester translucent ridging, fitting & fixing circular corrugated aluminium sheet, tor steel rods/hysd bars/tmt bars(jsw/jspl/shyam/srmb/bmasl/elecrosteel/ssl)(fe415/fe500/fe500d conforms to is: 1786), tor steel rods/hysd bars/tmt bars (other than sail/tata/rinl/jsw/jspl/shyam/srmb/bmasl/elecrosteel/ssl)(fe415/fe500/fe500d conforms to is: 1786), brick aggregate (single size):40 mm nominal size, moorum, stone aggregate(single size):63 mm nominal size, river bed material, geotextile 120 gram per sqm membrane, hire charges of shuttering plank (25mm-30mm thick) with prop including all fittings, hire charges of shuttering plank (25mm-30mm thick) without prop including all fittings, hire charges of shuttering plank (above 30mm-37mm thick) with prop including all fittings, thermocol 12.5 mm thick., polythene sheet (150 gm

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

Central Government And Public Sector

CTN :45738278 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For providing of custom bid for services - plb pipe laying by hdd open trench method of cable blowing pulling optical fiber cable splicing and associated works for ph vi patchwork in keonjhar ghatagaon 48f optical fiber cable route under bhubaneshwar ba

Central Government And Public Sector

CTN :45738274 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For providing of custom bid for services - plb pipe laying by hdd open trench method of cable blowing pulling optical fiber cable splicing and associated works for cuttack to dhenkanal 48f optical fiber cable route under bhubaneshwar ba

Central Government And Public Sector

CTN :45333186 Due date: 14 Jul, 202614 Jul, 2026 59.95 Lacs
Tender For corrigendum : supply of main fire pump , diesel driven pump , jockey pump , terrace pump , control panel , starter , m s pipe , internal hydrant valve , external yard hydrant valve , butterfly valve , sfc of butterfly valve , orifice plate , pitc non return valve , stainless steel y strainer , pitc of stainless steel y strainer , hose pipe , first aid hose reel , short branch pipe , fire brigade connection , foot valve , air vessel , pressure switch , pressure gauge , control valve , hose cabinet , cutting holes , supply of cable , laying of cable , end termination , fire cable , cable tray , earthing , gi strip , gi strip , earth wire , gi pipe

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking

State Government

CTN :45705912 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For fixing bell mouths bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the engineer-in-charge. size of the main with which connection is to be made. 1. up to 200 mm internal diametre ,manhole chambers providing and fixing sfrc manhole covers and frames marked with is: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the engineer-in-charge. 1. type:- extra heavy duty set (ehd-35) 560mm clear opening, earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by engineer-in-charge. 1. all kinds of soil ,demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2. nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 6. 1:4:8 (1 cement : 4 coarse sand (zone-iii) : 8 graded stone aggregate 40 mm nominal size) .,steel reinforcement steel reinforcement for r.c.c. work, where not included in the complete rate of rcc, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level note: reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. thermo-mechanically treated bars of grade fe-500d or more,brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor iv level in all shapes and sizes in : 1. cement mortar 1:4 (1 cement : 4 coarse sand)
 Loading, Please wait...

Connect us via What's Up