Web Analytics Made Easy - StatCounter

Plc System Repair Tenders

Get complete information related to latest Plc System Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plc System Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plc System Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :45712936 Due date: 13 Jul, 202613 Jul, 2026 19.20 Lacs
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor

corporations/Associations/Others

CTN :45321766 Due date: 15 Jun, 202615 Jun, 2026 45.73 Lacs
Tender For procurement of electrical spares and consumables for 220 kv and 33kv switch yard at khodri power station - 245 kv lightening arrester, discharge current 10ka, frequency 50 hz,pressure relief class 40 ka(rms), long duration discharge class 3, m.c.o.v. 56 kv, make: oblum electrical industries pvt. ltd. /cg power and industrial solution ltd. or eq make as approved by engineer in charge., 145 kv lightening arrester outdoor type ,suitable for 145kv system voltage , discharge current 10ka, freq. 50 hz, high current impulse (4/10 s) 100 ka, rated lightning impulse withstand voltage 1.2/50 s - 650 kvp, polymer based (single phase) make-oblum electrical industries pvt. ltd. /cg power and industrial solution ltd,/ htachi / siemens india ltd or eq make as approved by engineer in charge., auxiliary switch (stack) 5no + 5nc, 220v, dc, make: crompton, hitachi or eq make as approved by engineer in charge for 220kv cgl make sf6 circuit breaker., surge monitor/surge counter with leakage current meter suitable for 220 kv lightening arrestor , make: cg power and industrial solution ltd./ oblum electrical industries pvt. ltd., 33kv ct indoor type , 3 core, 15va each, ratio 650-350/1 a + 1a , class 0.2s(2 core metering) & 5p10 (protection), str: 25ka for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge., 33kv ct indoor type, 3 core, 15va each, ratio 300-150/1 a + 1a , class 0.2s( 2 core metering) & (5p10 protection, str: 25ka, for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge, control motor, type c21, 2.6 a, 230v ac/dc, o/p 0.3kw, sr. no: 042-901, m/y 03/08, 750/ min. make: kpt shirol or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 7no+6nc (stack), 250 volt dc, make: crompton, hitachi or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 8no+ 8nc, 220v, dc, (motor drive ). make: abb/ hitachi or eq make as approved by engineer in charge for 245 kv, abb make isolator., 220 v, dc, close or trip-1 coil ( part no. exin - 400834 - r9)make: abb/hitachi or eq make as approved by engineer in charge for 145kv, abb make sf6 breaker., rectifier 15 a, 220 v, ac (part no. 1hyn-450040p1 ) make: abb/ hitachi or eq make as approved by engineer in chargefor 245kv, abb make isolator, mcb (2 pole,3a, 220v, dc ), over current earth fault relay, mc61a-nx, cat no : mc61anx2200, make: l&t electrical & automation, or eq make as approved by engineer in charge for 33kv sf6 braeker., 33kv busbar support insulator (epoxy) . make: universal engg. corporation,star electrical engg. works or eq make as approved by engineer in charge.(as per sample), epoxy bushing/ fixed contact of "r","y" &"b" phase bottom side for 33kv cgl make panel (as per sample), epoxy bushing/ fixed contact "r","y" &"b" phase top side for 33kv cgl make panel (as per sample), ratech wheel of 33kv sf6 breaker, cgl make, flexible contact of 33kv sf6 breaker finger, cgl make (as per sample), silica gel blue crystal in mesh size of 15 mm to 35 mm duly packed in poly lined moisture proof m s drums/carton, heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 185 mm 33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- , 185 mm 33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., p g clamp deer/panther for 220 kv conductor, p g tclamp deer/ zebra, for 220 kv conductor, p g clamp deer/ trantulla for 220 kv conductor, p g clamp tarantula/ trantulla for 220 kv conductor, p g clamp deer/deer for 220 kv conductor, p g clamp made of aluminum-alloy suitable for zebra to trantulla conductor with 4 nos bolt - n
 Loading, Please wait...

Connect us via What's Up