Web Analytics Made Easy - StatCounter

Plough Feeder Tenders

Get complete information related to latest Plough Feeder Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plough Feeder Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plough Feeder Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government/Public Sector

CTN :45725350 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For providing of custom bid for services - mod and inst work in sinter dispatch series; modification and installation works in sinter dispatch series of sp-ii 1.modification of drive platform for conveyors c-74, c-75 and c-76 dismantling of the existing drive system platform and associated structures of conveyors c-74 and c-75 in the sinter dispatch series of sp-ii. decoupling and removal of the existing gearbox and motor drive assemblies of c-74 and c-75. dismantling of the existing drive stools and platform base structures. fabrication of new drive stools and drive platform for installation of motor and gearbox as per drawing. erection and installation of the newly fabricated stool and drive platform, followed by mounting and alignment of the new motor and gearbox assemblies. for conveyor c-76, the scope includes: decoupling and removal of the existing motor. dismantling of the existing motor stool. fabrication of a new motor stool as per drawing. installation and alignment of the new stool and motor, followed by proper coupling. 2.fabrication and installation of plough feeder for conveyor c-72 fabrication and installation of a new plough feeder on conveyor c-72 for diversion of sinter material to the sinter ground storage yard. the plough feeder shall be fabricated and installed as per drawing and site instructions, including all necessary structural supports, fittings, and alignment. the above-mentioned works will be considered and measured as one (01) activity unit. labour,service & like charges % : 100.00 supply comp % : 0.00

State Government

CTN :45624709 Due date: 26 Jun, 202626 Jun, 2026 15.09 Lacs
Tender For procurement of spares for rexroth hydraulic power pack of plough feeder for chp-210 mw atps mppgcl chachai - axial piston pump a4vsd, unloading relief valve d8w, directional control valve 4we

Central Government/Public Sector

CTN :45484139 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For providing of facility management services - lumpsum based - manpower deployment for plough feeders and mobile trippers operation in chp ntpc-stg-3&4 vstps for year 2027-2029; manpower deployment for plough feeders and mobile trippers operation in chp ntpc-stg-3&4..

CTN :45429321 Due date: 25 Jun, 202625 Jun, 2026 8.00 Lacs
Tender For procurement of kawasaki make hydraulic motor wi speed sensor-iam 800h3 for plough feeders working at ocp3 chp, rg2 on specific make basis.

Central Government/Public Sector

CTN :44669955 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For corrigendum : procurement of fairfield make planetary gearbox torque_hub completeassembly for stg 1 plough feeders of chp at fstps.

CTN :45364887 Due date: 29 May, 202629 May, 2026 6.00 Lacs
Tender For procurement of 1200tph plough feeder hydraulic power pack spares from oem m/s. maha hydraulics private limited on proprietary basis for goleti chp, bellampalli area.

Central Government/Public Sector

CTN :45167791 Due date: 30 May, 202630 May, 2026 2.15 Lacs
Tender For corrigendum : repairing and overhauling of 02 nos. of travel gearbox of plough feeder no. 6 and 01 no of shanti gearbox of plough feeder no.1 of chp, bina project.

Central Government/Public Sector

CTN :45105407 Due date: 25 May, 202625 May, 2026 NA
Tender For corrigendum : supply of supply of 20tr ductable package units , itc of 20tr package unit , pressure testing and vaccumming and nitrogen flushout , refrigerant charging entire system , ms structure modification for odu mounting arrangement , dismantling of existing machine , refrigerant piping and modification , communication cable between idu and odu , canvas connection with zip on machine outlet , gi 22gauge duct mouth connection modification , acousting insulation 15 mm thick for the mouth connection modification piece , lifting shifting and positioning of the machines , transportation , comprehensive maintenance after completion of warranty 1st year , comprehensive maintenance after completion of warranty 2nd year , comprehensive maintenance after completion of warranty 3rd year , comprehensive maintenance after completion of warranty 4th year , comprehensive maintenance after completion of warranty 5th year
 Loading, Please wait...

Connect us via What's Up